Correlation between internal fiducial tumor motion and external marker motion for liver tumors imaged with 4D-CT

被引:111
作者
Beddar, A. Sam
Kainz, Kristofer
Briere, Tina Marie
Tsunashima, Yoshikazu
Pan, Tinsu
Prado, Karl
Mohan, Radhe
Gillin, Michael
Krishnan, Sunil
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Unit 94, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Diagnost Imaging, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2007年 / 67卷 / 02期
关键词
4D-CT imaging; tumor motion; respiratory gating; internal fiducials; hepatobiliary cancer;
D O I
10.1016/j.ijrobp.2006.10.007
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We investigated the correlation between the motions of an external marker and internal fiducials implanted in the liver for 8 patients undergoing respiratory-based computed tomography (four-dimensional CT [4D-CT]) procedures. Methods and Materials: The internal fiducials were gold seeds, 3 rum in length and 1.2 mm in diameter. Four patients each had one implanted fiducial, and the other four had three implanted fiducials. The external marker was a plastic box, which is part of the Real-Time Position Management System (RPM) used to track the patient's respiration. Each patient received a standard helical CT scan followed by a time-correlated CT-image acquisition (4D-CT). The 4D-CT images were reconstructed in 10 separate phases covering the entire respiratory cycle. Results: The internal fiducial motion is predominant in the superior-inferior direction, with a range of 7.5-17.5 mm. The correlation between external respiration and internal fiducial motion is best during expiration. For 2 patients with their three fiducials separated by a maximum of 3.2 cm, the motions of the fiducials were well correlated, whereas for 2 patients with more widely spaced fiducials, there was less correlation. Conclusions: In general, there is a good correlation between internal fiducial motion imaged by 4D-CT and external marker motion. We have demonstrated that gating may be best performed at the end of the respiratory cycle. Special attention should be paid to gating for patients whose fiducials do not move in synchrony, because targeting on the correct respiratory amplitude alone would not guarantee that the entire tumor volume is within the treatment field. (c) 2007 Elsevier Inc.
引用
收藏
页码:630 / 638
页数:9
相关论文
共 20 条
[1]   A technique for respiratory-gated radiotherapy treatment verification with an EPID in cine mode [J].
Berbeco, RI ;
Neicu, T ;
Rietzel, E ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3669-3679
[2]   Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates [J].
Berbeco, RI ;
Nishioka, S ;
Shirato, H ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3655-3667
[3]   Abdominal organ motion measured using 4D CT [J].
Brandner, Edward D. ;
Wu, Andrew ;
Chen, Hungcheng ;
Heron, Dwight ;
Kalnicki, Shalom ;
Komanduri, Krishna ;
Gerszten, Kristina ;
Burton, Steve ;
Ahmed, Irfan ;
Shou, Zhenyu .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (02) :554-560
[4]   Feasibility of a novel deformable image registration technique to facilitate classification, targeting, and monitoring of tumor and normal tissue [J].
Brock, KK ;
Dawson, LA ;
Sharpe, MB ;
Moseley, DJ ;
Jaffray, DA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (04) :1245-1254
[5]   Relation of external surface to internal tumor motion studied with cine CT [J].
Chi, Pai-Chun Melinda ;
Balter, Peter ;
Luo, Dershan ;
Mohan, Radhe ;
Pan, Tinsu .
MEDICAL PHYSICS, 2006, 33 (09) :3116-3123
[6]   The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy [J].
Dawson, LA ;
Brock, KK ;
Kazanjian, S ;
Fitch, D ;
McGinn, CJ ;
Lawrence, TS ;
Ten Haken, RK ;
Balter, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (05) :1410-1421
[7]   The correlation between internal and external markers for abdominal tumors: Implications for respiratory gating [J].
Gierga, DP ;
Brewer, J ;
Sharp, GC ;
Betke, M ;
Willett, CG ;
Chen, GTY .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (05) :1551-1558
[8]   On the use of EPID-based implanted marker tracking for 4D radiotherapy [J].
Keall, PJ ;
Todor, AD ;
Vedam, SS ;
Bartee, CL ;
Siebers, JV ;
Kini, VR ;
Mohan, R .
MEDICAL PHYSICS, 2004, 31 (12) :3492-3499
[9]   Measurement of lung tumor motion using respiration-correlated CT [J].
Mageras, GS ;
Pevsner, A ;
Yorke, ED ;
Rosenzweig, KE ;
Ford, EC ;
Hertanto, A ;
Larson, SM ;
Lovelock, DM ;
Erdi, YE ;
Nehmeh, SA ;
Humm, JL ;
Ling, CC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (03) :933-941
[10]   Respiratory gated irradiation system for heavy-ion radiotherapy [J].
Minohara, S ;
Kanai, T ;
Endo, M ;
Noda, K ;
Kanazawa, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04) :1097-1103