Pulse Rate Variability Analysis by Video Using Face Detection and Tracking Algorithms

被引:0
作者
Melchor Rodriguez, A. [1 ]
Ramos Castro, J. [1 ]
机构
[1] UPC, Dept Elect Engn, Grp Biomed & Elect Instrumentat, Barcelona, Spain
来源
2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2015年
关键词
HEART-RATE-VARIABILITY; NONCONTACT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Heart rate variability (HRV) is a physiological parameter which has increased its importance in recent years due to its relationship with the autonomic nervous system (ANS) and cardiovascular disorders. In this work the pulse rate variability (PRV) is measured as a surrogate measurement of HRV using only a video of the face of the subject. Because of pulse rate signals obtained by video are largely affected by the person movements and the analyzed region of interest (ROI), we propose the application of face detection and tracking algorithms as a solution to the artifacts produced by these factors. We compare the obtained results of the proposed method with a pulse sensor signal of a reference system. The statistical analysis results show good agreement between both methods.
引用
收藏
页码:5696 / 5699
页数:4
相关论文
共 19 条
  • [1] Heart rate variability: a review
    Acharya, U. Rajendra
    Joseph, K. Paul
    Kannathal, N.
    Lim, Choo Min
    Suri, Jasjit S.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (12) : 1031 - 1051
  • [2] Changes in heart rate variability of athletes during a training camp
    Baumert, Mathias
    Brechtel, Lars
    Lock, Juergen
    Voss, Andreas
    [J]. BIOMEDIZINISCHE TECHNIK, 2006, 51 (04): : 201 - 204
  • [3] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [4] Camm AJ, 1996, EUR HEART J, V17, P354
  • [5] Capdevila L, 2012, IEEE ENG MED BIO, P5646, DOI 10.1109/EMBC.2012.6347275
  • [6] Blásquez JCC, 2009, PSICOTHEMA, V21, P531
  • [7] Photoplethysmography pulse rate variability as a surrogate measurement of heart rate variability during non-stationary conditions
    Gil, E.
    Orini, M.
    Bailon, R.
    Vergara, J. M.
    Mainardi, L.
    Laguna, P.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2010, 31 (09) : 1271 - 1290
  • [8] Lee J, 2013, 35 ANN INT C IEEE EN
  • [9] Lucas B. D., 1981, P INT JOINT C ART IN, P674, DOI DOI 10.5555/1623264.1623280
  • [10] The Advantages of Wearable Green Reflected Photoplethysmography
    Maeda, Yuka
    Sekine, Masaki
    Tamura, Toshiyo
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2011, 35 (05) : 829 - 834