Comparison of Endothelial Barrier Functional Recovery After Implantation of a Novel Biodegradable-Polymer Sirolimus-Eluting Stent in Comparison to Durable- and Biodegradable-Polymer Everolimus-Eluting Stents

被引:10
|
作者
Sakamoto, Atsushi [1 ]
Torii, Sho [1 ]
Jinnouchi, Hiroyuki [1 ]
Guo, Liang [1 ]
Cornelissen, Anne [1 ]
Kuntz, Salome [1 ]
Cheng, Qi [1 ]
Fernandez, Raquel [1 ]
Paek, Ka Hyun [1 ]
Harris, Kathryn [2 ]
Srivastava, Mukta C. [2 ]
Kolodgie, Frank D. [1 ]
Virmani, Renu [1 ]
Finn, Aloke, V [1 ,2 ]
机构
[1] CVPath Inst Inc, 19 Firstfield Rd, Gaithersburg, MD 20878 USA
[2] Univ Maryland, Sch Med, Baltimore, MD 21201 USA
关键词
Drug eluting stent; Biodegradable polymer; Durable polymer; Endothelial function; Vascular permeability;
D O I
10.1016/j.carrev.2020.08.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: The advantage of biodegradable-polymer drug-eluting stents (BP-DES) versus durable-polymer (DP) DES remains uncertain. We compared neointimal formation and endothelial barrier function of new BP sirolimus-eluting stents (BP-SES, BuMA Supreme (R)) to other contemporary BP-DES, DP-DES, and bare metal stents (BMS). Methods and results: Light microscopic assessment in swine coronary arteries showed comparable neointimal formation between BP-SES and DP everolimus-eluting stent (DP-EES). The performance of BP-SES was compared with DP-EES (Xience Xpedition (R)), BP-EES (Synergy (R)), and BMS (Multi-Link Vision (R)) at 45- and 90-days in rabbit ilio-femoral arteries using Evans blue dye (EBD) followed by immunostaining for endothelial barrier proteins (p120/vascular endothelial-cadherin [VE-cad]) to evaluate endothelial barrier function and scanning electron microscopy (SEM) to determine strut tissue coverage. BMS followed by BP-SES and BP-EES exhibited smaller EBD positive areas versus that of DP-EES at 45- and 90-days. p120/VE-cad immunostaining and SEM-determined strut coverage was greater at 45- and 90-days for BMS followed by all DESs. Regardless of stent type, the lack of p120/VE-cad co-localization showed greater leukocyte and platelet aggregation. Conclusion: Three types of DES showed different endothelial healing pattern regardless their equivalent suppression of neointimal formation. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 50 条
  • [21] NOBORI™ biodegradable-polymer biolimus-eluting stent versus durable-polymer drug-eluting stents: A meta-analysis
    Zhang, Yao-Jun
    Ye, Fei
    Iqbal, Javaid
    Dong, Sheng-Jie
    Bourantas, Christos V.
    Tian, Nai-Liang
    Serruys, Patrick W.
    Chen, Shao-Liang
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 174 (01) : 151 - 153
  • [22] Early vascular healing with rapid breakdown biodegradable polymer sirolimus-eluting versus durable polymer everolimus-eluting stents assessed by optical coherence tomography
    Tada, Tomohisa
    Byrne, Robert A.
    Schuster, Tibor
    Cuni, Rezarta
    Kitabata, Hironori
    Tiroch, Klaus
    Dirninger, Alfred
    Gratze, Franz
    Kaspar, Klaus
    Zenker, Gerald
    Joner, Michael
    Schomig, Albert
    Kastrati, Adnan
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2013, 14 (02) : 84 - 89
  • [23] Everolimus-Eluting Biodegradable Polymer Versus Everolimus-Eluting Durable Polymer Stent for Coronary Revascularization in Routine Clinical Practice
    Zanchin, Christian
    Ueki, Yasushi
    Zanchin, Thomas
    Haner, Jonas
    Otsuka, Tatsuhiko
    Stortecky, Stefan
    Koskinas, Konstantinos C.
    Siontis, George C. M.
    Praz, Fabien
    Moschovitis, Aris
    Hunziker, Lukas
    Valgimigli, Marco
    Pilgrim, Thomas
    Heg, Dik
    Windecker, Stephan
    Raber, Lorenz
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (17) : 1665 - 1675
  • [24] Comparison of the biodegradable polymer everolimus-eluting stent with contemporary drug-eluting stents: A systematic review and meta-analysis
    Picard, Fabien
    Pighi, Michele
    de Hemptinne, Quentin
    Airaksinen, Juhani
    Vinco, Giulia
    de Pommereau, Aurelien
    Biancari, Fausto
    Varenne, Olivier
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 278 : 51 - 56
  • [25] Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable-Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularization: 2-Year Results of the BIOSCIENCE Trial
    Zbinden, Rainer
    Piccolo, Raffaele
    Heg, Dik
    Roffi, Marco
    Kurz, David J.
    Muller, Olivier
    Vuilliomenet, Andre
    Cook, Stephane
    Weilenmann, Daniel
    Kaiser, Christoph
    Jamshidi, Peiman
    Franzone, Anna
    Eberli, Franz
    Juni, Peter
    Windecker, Stephan
    Pilgrim, Thomas
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2016, 5 (03):
  • [26] Angioscopic Assessment of Arterial Repair Following Biodegradable Polymer-Coated Biolimus A9-Eluting Stent Implantation - Comparison With Durable Polymer-Coated Sirolimus-Eluting Stent
    Awata, Masaki
    Uematsu, Masaaki
    Sera, Fusako
    Ishihara, Takayuki
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Nagata, Seiki
    CIRCULATION JOURNAL, 2011, 75 (05) : 1113 - 1119
  • [27] Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry
    Satoshi Suzuki
    Yohei Sotomi
    Tomoaki Kobayashi
    Yuma Hamanaka
    Shimpei Nakatani
    Ichiro Shiojima
    Yasushi Sakata
    Atsushi Hirayama
    Yoshiharu Higuchi
    The International Journal of Cardiovascular Imaging, 2019, 35 : 973 - 980
  • [28] Early vessel healing after implantation of biodegradable-polymer and durable-polymer drug-eluting stent: 3-month angioscopic evaluation of the RESTORE registry
    Suzuki, Satoshi
    Sotomi, Yohei
    Kobayashi, Tomoaki
    Hamanaka, Yuma
    Nakatani, Shimpei
    Shiojima, Ichiro
    Sakata, Yasushi
    Hirayama, Atsushi
    Higuchi, Yoshiharu
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2019, 35 (06) : 973 - 980
  • [29] Biodegradable polymer biolimus-eluting stent versus durable polymer everolimus-eluting stent in patients with acute myocardial infarction
    Lee, Hyun Jong
    Park, Taek Kyu
    Bin Song, Young
    Choi, Young Jin
    Yu, Cheol Woong
    Yang, Jeong Hoon
    Hahn, Joo-Yong
    Choi, Seung-Hyuk
    Choi, Rak Kyeong
    Choi, Jin-Ho
    Park, Jin Sik
    Kim, Je Sang
    Kim, Tae Hoon
    Jang, Ho Joon
    Lee, Sang Hoon
    Shim, Won Heum
    Roh, Young Moo
    Gwon, Hyeon-Cheol
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 183 : 190 - 197
  • [30] Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation
    Koppara, Tobias
    Joner, Michael
    Bayer, Gerd
    Steigerwald, Kristin
    Diener, Tobias
    Wittchow, Eric
    THROMBOSIS AND HAEMOSTASIS, 2012, 107 (06) : 1161 - 1171