Patellofemoral joint kinematics and contact pressures in total knee arthroplasty

被引:59
作者
Lee, TQ
Gerken, AP
Glaser, FE
Kim, WC
Anzel, SH
机构
[1] UNIV CALIF IRVINE,DEPT ORTHOPAED SURG,ORANGE,CA 92668
[2] GOTHENBURG UNIV,DEPT BIOMAT HANDICAP RES,GOTHENBURG,SWEDEN
关键词
D O I
10.1097/00003086-199707000-00033
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patellofemoral joint kinematics, contact areas, and contact pressures were measured concomitantly before and after total knee arthroplasty in 10 fresh frozen human cadaver knees using an Instron machine, a custom patellofemoral joint testing jig, axial bone markers, a continuous video digitizing system, and Fuji pressure sensitive film, The implant used in this study was the Kirschner Performance Knee System with an all polyethylene, domed patellar component, For all tests, the patella was aligned in its anatomically neutral position, Patellofemoral joint contact areas decreased as much as 19-fold after total knee arthroplasty, Mean patellofemoral joint contact pressures increased as much as 32-fold, and peak patellofemoral joint contact pressures increased as much as 22-fold after total knee arthroplasty, No statistically significant differences between preoperative and postoperative specimens were observed with respect to the patellofemoral, patellotibial, or patellar tilt angles from 30 degrees to 120 degrees knee flexion, Thus, the elevated patellofemoral joint contact pressures observed after total knee arthroplasty in vitro are not a primary consequence of iatrogenically altered patellofemoral kinematics.
引用
收藏
页码:257 / 266
页数:10
相关论文
共 37 条
[1]   INVITRO MEASUREMENT OF STATIC PRESSURE DISTRIBUTION IN SYNOVIAL JOINTS .2. RETROPATELLAR SURFACE [J].
AHMED, AM ;
BURKE, DL ;
YU, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (03) :226-234
[2]  
Ahmed AM, 1988, T ORTHOP RES SOC, V13, P280
[3]  
ATESHIAN GA, 1992, ADV BIOENG, V22, P35
[4]  
BERGER RA, 1993, CLIN ORTHOP RELAT R, V286, P40
[5]   LONG-TERM COMPLICATIONS AFTER TOTAL KNEE ARTHROPLASTY WITH OR WITHOUT RESURFACING OF THE PATELLA [J].
BOYD, AD ;
EWALD, FC ;
THOMAS, WH ;
POSS, R ;
SLEDGE, CB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (05) :674-681
[6]  
Briard JL, 1989, J ARTHROPLASTY S, V4, P87
[7]  
Brick GW, 1988, CLIN ORTHOP RELAT R, V231, P163
[8]  
COLLIER JP, 1991, CLIN ORTHOP RELAT R, V273, P198
[9]   A NEW OPTICAL-SYSTEM FOR THE DETERMINATION OF DEFORMATIONS AND STRAINS - CALIBRATION CHARACTERISTICS AND EXPERIMENTAL RESULTS [J].
DERWIN, KA ;
SOSLOWSKY, LJ ;
GREEN, WDK ;
ELDER, SH .
JOURNAL OF BIOMECHANICS, 1994, 27 (10) :1277-+
[10]   THE EFFECT OF ALIGNMENT OF THE IMPLANT ON FRACTURES OF THE PATELLA AFTER CONDYLAR TOTAL KNEE ARTHROPLASTY [J].
FIGGIE, HE ;
GOLDBERG, VM ;
FIGGIE, MP ;
INGLIS, AE ;
KELLY, M ;
SOBEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1989, 71A (07) :1031-1039