Selectivity enhancement of anion-responsive electrodes by pulsed chronopotentiometry

被引:34
作者
Gemene, Kebede L. [1 ]
Shvarev, Alexey [1 ]
Bakker, Eric [1 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
ion-selective electrodes; selectivity enhancement; clinical analysis; anion detection; solvent polymeric membrane;
D O I
10.1016/j.aca.2006.09.042
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A large and robust selectivity improvement of ion-selective electrodes is presented for the measurement of abundant ions. An improvement in selectivity by more than two orders of magnitude has been attained for the hydrophilic chloride ions measured in a dilute background of the lipophilic ions perchlorate and salicylate in a pulsed chronopotentiometric measurement mode. This is attributed to a robust kinetic discrimination of the dilute lipophilic ions in this measuring mode, which is not possible to achieve in classical potentiometry. Maximum tolerable concentrations of the interfering ions are found to be on the order of 30 mu M before causing substantial changes in potential. As an example of practical relevance, the robust detection of chloride in 72 mu M salicylate (reflecting 1: 10 diluted blood) with a detection limit of 0.5 mM chloride is demonstrated. Corresponding potentiometric sensors did not give a useful chloride response under these conditions. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 29 条
[11]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[12]  
Jadhav S, 2000, ELECTROANAL, V12, P1251, DOI 10.1002/1521-4109(200011)12:16<1251::AID-ELAN1251>3.0.CO
[13]  
2-P
[14]   ASYMMETRIC CARBONATE ION-SELECTIVE CELLULOSE-ACETATE MEMBRANE ELECTRODES WITH REDUCED SALICYLATE INTERFERENCE [J].
LEE, KS ;
SHIN, JH ;
HAN, SH ;
CHA, GS ;
SHIN, DS ;
KIM, HD .
ANALYTICAL CHEMISTRY, 1993, 65 (21) :3151-3155
[15]   RESPONSE MECHANISM OF SOLID-STATE ION-SELECTIVE ELECTRODES IN THE PRESENCE OF INTERFERING IONS [J].
LEWENSTAM, A ;
HULANICKI, A ;
SOKALSKI, T .
ANALYTICAL CHEMISTRY, 1987, 59 (11) :1539-1544
[16]   Optical determination of ionophore diffusion coefficients in plasticized poly(vinyl chloride) sensing films [J].
Long, R ;
Bakker, E .
ANALYTICA CHIMICA ACTA, 2004, 511 (01) :91-95
[17]   Improved selectivity and detection limit of the carbonate-selective electrode [J].
Maj-Zurawska, M ;
Ziemianek, D ;
Mikolajczuk, A ;
Mieczkowski, J ;
Lewenstam, A ;
Hulanicki, A ;
Sokalski, T .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (04) :524-526
[18]   Investigation of salicylate interference on anion selective electrodes [J].
Maj-Zurawska, M ;
Sokalski, T ;
Mulik, E ;
Kotliñska, A ;
Lewandowski, R ;
Hulanicki, A .
ANALYTICAL LETTERS, 2001, 34 (09) :1413-1420
[19]   Calcium pulstrodes with 10-fold enhanced sensitivity for measurements in the physiological concentration range [J].
Makarychev-Mikhailov, S ;
Shvarev, A ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2006, 78 (08) :2744-2751
[20]   Pulstrodes: Triple pulse control of potentiometric sensors [J].
Makarychev-Mikhailov, S ;
Shvarev, A ;
Bakker, E .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2004, 126 (34) :10548-10549