Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry

被引:54
作者
Faqehi, Abdullah M. M. [1 ]
Cobice, Diego F. [1 ]
Naredo, Gregorio [2 ]
Mak, Tracy C. S. [1 ]
Upreti, Rita [1 ]
Gibb, Fraser W. [1 ]
Beckett, Geoffrey J. [3 ]
Walker, Brian R. [1 ,2 ]
Homer, Natalie Z. M. [2 ]
Andrew, Ruth [1 ,2 ]
机构
[1] Univ Edinburgh, Queens Med Res Inst, Univ British Heart Fdn Ctr Cardiovasc Sci, Endocrinol, 47 Little France Crescent, Edinburgh EH16 4TJ, Midlothian, Scotland
[2] Queens Med Res Inst, Edinburgh Clin Res Facil, Mass Spectrometry Core, 47 Little France Crescent, Edinburgh EH16 4TJ, Midlothian, Scotland
[3] Royal Infirm Edinburgh NHS Trust, Clin Biochem, 51 Little France Crescent, Edinburgh EH16 4SA, Midlothian, Scotland
基金
英国惠康基金;
关键词
Estrone; Estradiol; Derivatization; Liquid chromatography; Mass spectrometry; Methylpyridinium ether; SOLID-PHASE EXTRACTION; STEROIDAL ESTROGENS; SURFACE-WATER; ESTRADIOL; ESTRONE; HORMONES; QUANTIFICATION; ASSAY;
D O I
10.1016/j.talanta.2015.12.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Estrogens circulate at concentrations less than 20 pg/mL in men and postmenopausal women, presenting analytical challenges. Quantitation by immunoassay is unreliable at these low concentrations. Liquid chromatography tandem mass spectrometry (LC-MS/MS) offers greater specificity and sometimes greater sensitivity, but ionization of estrogens is inefficient. Introduction of charged moieties may enhance ionization, but many such derivatives of estrogens generate non-specific product ions originating from the "reagent" group. Therefore an approach generating derivatives with product ions specific to individual estrogens was sought. Estrogens were extracted from human plasma and serum using solid phase extraction and derivatized using 2-fluoro-1-methylpyridinium-p-toluenesulfonate (FMP-TS). Electrospray in positive mode with multiple reaction monitoring using a QTrap 5500 mass spectrometer was used to quantify "FMP" derivatives of estrogens, following LC separation. Transitions for the FMP derivatives of estrone (El) and estradiol (E2) were compound specific (m/z 362 -> 238 and m/z 364 -> 128, respectively). The limits of detection and quantitation were 0.2 pg on column and the method was linear from 1-400 pg/sample. Measures of intra- and inter-assay variability, precision and accuracy were acceptable (< 20%). The derivatives were stable over 24 h at 10 degrees C (7-9% degradation). Using this approach, El and E2, respectively were detected in human plasma and serum: pre-menopausal female serum (0.5 mL) 135-473, 193-722 pmol/L; male plasma (1 mL) 25-111, 60180 pmol/L and post-menopausal female plasma (2 mL), 22-78, 29-50 pmol/L. Thus FMP derivatization, in conjunction with LC-MS/MS, is suitable for quantitative analysis of estrogens in low abundance in plasma and serum, offering advantages in specificity over immunoassay and existing MS techniques. (C) 2016 The Authors. Published by Elsevier B.V. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:148 / 156
页数:9
相关论文
共 27 条
  • [1] Endogenous sex hormones and cardiovascular disease incidence in men
    Arnlov, Johan
    Pencina, Michael J.
    Amin, Shreyasee
    Nam, Byung-Ho
    Benjamin, Emelia J.
    Murabito, Joanne M.
    Wang, Thomas J.
    Knapp, Philip E.
    D'Agostino, Ralph B., Sr.
    Bhasin, Shalendar
    Vasan, Ramachandran S.
    [J]. ANNALS OF INTERNAL MEDICINE, 2006, 145 (03) : 176 - 184
  • [2] Bulk derivatization and cation exchange restricted access media-based trap-and-elute liquid chromatography-mass spectrometry method for determination of trace estrogens in serum
    Beinhauer, Jana
    Bian, Liangqiao
    Fan, Hui
    Sebela, Marek
    Kukula, Maciej
    Barrera, Jose A.
    Schug, Kevin A.
    [J]. ANALYTICA CHIMICA ACTA, 2015, 858 : 74 - 81
  • [3] Risks of obesity
    Bray, GA
    [J]. ENDOCRINOLOGY AND METABOLISM CLINICS OF NORTH AMERICA, 2003, 32 (04) : 787 - +
  • [4] Simultaneous quantification of multiple classes of phenolic compounds in blood plasma by liquid chromatography-electrospray tandem mass spectrometry
    Chang, Hong
    Wan, Yi
    Naile, Jonathan
    Zhang, Xiaowei
    Wiseman, Steve
    Hecker, Markus
    Lam, Michael H. W.
    Giesy, John P.
    Jones, Paul D.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (04) : 506 - 513
  • [5] Quantitative analysis of estradiol and six other steroid hormones in human saliva using a high throughput liquid chromatography-tandem mass spectrometry assay
    Gao, Wei
    Stalder, Tobias
    Kirschbaum, Clemens
    [J]. TALANTA, 2015, 143 : 353 - 358
  • [6] Grebe Stefan Kg, 2011, Clin Biochem Rev, V32, P5
  • [7] A comparison of three analytical techniques for the measurement of steroidal estrogens in environmental water samples
    Grover, D. P.
    Zhang, Z. L.
    Readman, J. W.
    Zhou, J. L.
    [J]. TALANTA, 2009, 78 (03) : 1204 - 1210
  • [8] Measurement of Estradiol in Human Serum by LC-MS/MS Using a Novel Estrogen-Specific Derivatization Reagent
    Keski-Rahkonen, Pekka
    Desai, Reena
    Jimenez, Mark
    Harwood, D. Tim
    Handelsman, David J.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (14) : 7180 - 7186
  • [9] Normal reference laboratory values
    Kratz, A
    Lewandrowski, KB
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (15) : 1063 - 1072
  • [10] High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol
    Kushnir, Mark M.
    Rockwood, Alan L.
    Bergquist, Jonas
    Varshavsky, Marina
    Roberts, William L.
    Yue, Bingfang
    Bunker, Ashley M.
    Meikle, A. Wayne
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 129 (04) : 530 - 539