Oxidation of organics in retentates from reverse osmosis wastewater reuse facilities

被引:214
作者
Westerhoff, Paul [1 ]
Moon, Hye [1 ]
Minakata, Daisuke [1 ]
Crittenden, John [1 ]
机构
[1] Arizona State Univ, Dept Civil Environm & Sustainable Engn, Tempe, AZ 85287 USA
关键词
Advanced oxidation process; Dissolved organic matter; Pharmaceutical; Ultraviolet; Ozone; Hydroxyl radical; HYDROXYL RADICALS; RATE CONSTANTS; CONCENTRATE; OZONATION; PRODUCTS; MATTER;
D O I
10.1016/j.watres.2009.04.010
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of membrane processes for wastewater treatment and reuse is rapidly expanding. organic, inorganic, and biological constituents are effectively removed by reverse osmosis (RO) membrane processes, but concentrate in membrane retentates Disposal of membrane concentrates is a growing concern. Applying advanced oxidation processes (AOPs) to RO retentate is logical because extensive treatment and energy inputs were expended to concentrate the organics, and it is cheaper to treat smaller flowstreams. AOPs (e.g., UV irradiation in the presence of titanium dioxide; UV/TiO(2)) can remove a high percentage of organic matter from RO retentates. The combination of AOPs and a simple biological system (e.g., sand filter) can remove higher levels of organic matter at lower UV dosages because AOPs produce biologically degradable material (e.g., organic acids) that have low hydroxyl radical rate constants, meaning that their oxidation, rather than that of the primary organic matter in the RO retentate, dictates the required UV energy inputs. At the highest applied UV dose (10 kWh m(-3)), the dissolved organic carbon (DOC) in the RO retentate decreased from similar to 40 to 8 mg L(-)1, of which approximately 6 mg L(-)1 were readily biologically degradable. Therefore, after combined UV treatment and biodegradation, the final DOC concentration was 2 mg L(-)1, representing a 91% removal. These results suggest that UV/TiO(2) plus biodegradation of RO retentates is feasible and would significantly reduce the organic pollutant loading into the environment from wastewater reuse facilities. (C) 2009 Published by Elsevier Ltd.
引用
收藏
页码:3992 / 3998
页数:7
相关论文
共 18 条
[1]  
Allgeier S. C., 1996, AWWA WAT QUAL TECHN
[2]   Oxidative degradation of textile waste water. Modeling reactor performance [J].
Balanosky, E ;
Herrera, F ;
Lopez, A ;
Kiwi, J .
WATER RESEARCH, 2000, 34 (02) :582-596
[3]   Ozonation of reverse osmosis concentrate: Kinetics and efficiency of beta blocker oxidation [J].
Benner, Jessica ;
Salhi, Elisabeth ;
Ternes, Thomas ;
von Gunten, Urs .
WATER RESEARCH, 2008, 42 (12) :3003-3012
[4]   CRITICAL-REVIEW OF RATE CONSTANTS FOR REACTIONS OF HYDRATED ELECTRONS, HYDROGEN-ATOMS AND HYDROXYL RADICALS (.OH/.O-) IN AQUEOUS-SOLUTION [J].
BUXTON, GV ;
GREENSTOCK, CL ;
HELMAN, WP ;
ROSS, AB .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1988, 17 (02) :513-886
[5]  
Chen Z, 2008, J ADV OXID TECHNOL, V11, P254
[6]   Advanced treatment of the reverse osmosis concentrate produced during reclamation of municipal wastewater [J].
Dialynas, Emmanuel ;
Mantzavinos, Dionissios ;
Diamadopoulos, Evan .
WATER RESEARCH, 2008, 42 (18) :4603-4608
[7]   Mechanistic and kinetic evaluation of organic disinfection by-product and assimilable organic carbon (AOC) formation during the ozonation of drinking water [J].
Hammes, Frederik ;
Salhi, Elisabeth ;
Koester, Oliver ;
Kaiser, Hans-Peter ;
Egli, Thomas ;
von Gunten, Urs .
WATER RESEARCH, 2006, 40 (12) :2275-2286
[8]  
HAND DW, 1995, J AM WATER WORKS ASS, V87, P84
[9]   A NEW SENSITIVE CHEMICAL ACTINOMETER .2. POTASSIUM FERRIOXALATE AS A STANDARD CHEMICAL ACTINOMETER [J].
HATCHARD, CG ;
PARKER, CA .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 235 (1203) :518-536
[10]  
Langlais B., 1991, Ozone in Water Treatment: Application and Engineering