Relationship between isometric contraction intensity and muscle hardness assessed by ultrasound strain elastography

被引:34
作者
Inami, Takayuki [1 ,2 ]
Tsujimura, Toru [1 ,3 ]
Shimizu, Takuya [4 ]
Watanabe, Takemasa [4 ]
Lau, Wing Yin [1 ]
Nosaka, Kazunori [1 ]
机构
[1] Edith Cowan Univ, Sch Med & Hlth Sci, Ctr Exercise & Sports Sci Res, 270 Joondalup Dr, Joondalup, WA 6027, Australia
[2] Waseda Univ, Fac Sport Sci, Tokorozawa, Saitama, Japan
[3] Tsujimura Surg Hosp, Kariya, Aichi, Japan
[4] Chukyo Univ, Grad Sch Hlth & Sport Sci, Nagoya, Aichi, Japan
基金
日本学术振兴会;
关键词
Gastrocnemius; Strain ratio; Muscle force; Pennation angle; Muscle thickness; SHEAR-WAVE ELASTOGRAPHY; SKELETAL-MUSCLE; MEDIAL GASTROCNEMIUS; ELASTIC-MODULUS; FORCE; STIFFNESS; ARCHITECTURE; EXERCISE; TENSION; TORQUE;
D O I
10.1007/s00421-016-3528-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction Ultrasound elastography is used to assess muscle hardness or stiffness; however, no previous studies have validated muscle hardness measures using ultrasound strain elastography (SE). This study investigated the relationship between plantar flexor isometric contraction intensity and gastrocnemius hardness assessed by SE. We hypothesised that the muscle would become harder linearly with an increase in the contraction intensity of the plantar flexors. Methods Fifteen young women (20.1 +/- 0.8 years) performed isometric contractions of the ankle plantar flexors at four different intensities (25, 50, 75, 100% of maximal voluntary contraction force: MVC) at 0 degrees plantar flexion. Using SE images, the strain ratio (SR) between the muscle and an acoustic coupler (elastic modulus 22.6 kPa) placed over the skin was calculated (muscle/coupler); pennation angle and muscle thickness were measured for the resting and contracting conditions. Results SR decreased with increasing contraction intensity from rest (1.28 +/- 0.20) to 25% (0.99 +/- 0.21), 50% (0.61 +/- 0.15), 75% (0.34 +/- 0.1) and 100% MVC (0.20 +/- 0.05). SR decreased linearly (P < 0.05) with increasing MVC from rest to 75% MVC, but levelled off from 75 and 100% MVC. SR was negatively correlated with pennation angle (r = -0.80, P < 0.01) and muscle thickness ( r = -0.78, P < 0.01). Conclusion SR appears to represent muscle hardness changes in response to contraction intensity changes, in the assumption that the gastrocnemius muscle contraction intensity is proportional to the plantar flexion intensity. We concluded that gastrocnemius muscle hardness changes could be validly assessed by SR, and the force-hardness relationship was not linear.
引用
收藏
页码:843 / 852
页数:10
相关论文
共 50 条
  • [41] The Relationship Between Muscle Mass Assessed Using Different Formulas and Insulin Resistance
    Tuzun, Sabah
    Sevinc, Elif
    CYPRUS JOURNAL OF MEDICAL SCIENCES, 2018, 3 (02): : 81 - 84
  • [42] RELATIONSHIP BETWEEN ELECTRICAL AND VIBRATORY OUTPUT OF MUSCLE DURING VOLUNTARY CONTRACTION AND FATIGUE
    ZWARTS, MJ
    KEIDEL, M
    MUSCLE & NERVE, 1991, 14 (08) : 756 - 761
  • [43] Relationship between muscle metabolic rate and muscle torque complexity during fatiguing intermittent isometric contractions in humans
    Pethick, Jamie
    Winter, Samantha L.
    Burnley, Mark
    PHYSIOLOGICAL REPORTS, 2019, 7 (18):
  • [44] The relationship between sarcopenic obesity and changes in quadriceps muscle thickness and echo intensity in patients with stroke
    Maruyama, Motoki
    Kagaya, Yuki
    Kajiwara, Sota
    Oikawa, Takuto
    Horikawa, Manabu
    Fujimoto, Mika
    Sasaki, Masahiro
    TOPICS IN STROKE REHABILITATION, 2024, 31 (08) : 828 - 837
  • [45] Using the Area Ratio to Differentiate Between Benign and Malignant Breast Lesions: Ultrasound Strain Elastography versus Contrast Enhanced Ultrasound
    Zhao, Lixia
    Zhang, Lei
    Zheng, Shuguang
    Zhao, Cheng
    Wang, Hongqiao
    Liu, Chunhui
    Chu, Xu
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2019, 9 (04) : 744 - 749
  • [46] The influence of subcutaneous fat on the relationship between body composition and ultrasound-derived muscle quality
    Ryan, Eric D.
    Shea, Nicholas W.
    Gerstner, Gena R.
    Barnette, Timothy J.
    Tweedell, Andrew J.
    Kleinberg, Craig R.
    APPLIED PHYSIOLOGY NUTRITION AND METABOLISM, 2016, 41 (10) : 1104 - 1107
  • [47] Relationship between shear modulus and passive tension of the posterior shoulder capsule using ultrasound shear wave elastography: A cadaveric study
    Iida, Naoya
    Taniguchi, Keigo
    Watanabe, Kota
    Miyamoto, Hiroki
    Taniguchi, Tatsuya
    Fujimiya, Mineko
    Katayose, Masaki
    JOURNAL OF BIOMECHANICS, 2020, 99 (99)
  • [48] Relationship between lower extremity isometric muscle strength and standing balance in patients with multiple sclerosis
    Citaker, Seyit
    Guclu-Gunduz, Arzu
    Yazici, Gokhan
    Bayraktar, Deniz
    Nazliel, Bijen
    Irkec, Ceyla
    NEUROREHABILITATION, 2013, 33 (02) : 293 - 298
  • [49] The relationship between elastography-based muscle properties and vertical jump performance, countermovement utilization ratio, and rate of force development
    Djuric, Daniel
    Plesa, Jernej
    Van Hooren, Bas
    Kozinc, Ziga
    Sarabon, Nejc
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2023, 123 (08) : 1789 - 1800
  • [50] The interaction between changes of muscle activation and cortical network dynamics during isometric elbow contraction: a sEMG and fNIRS study
    Wang, Xiaohan
    Luo, Zichong
    Zhang, Mingxia
    Zhao, Weihua
    Xie, Songyun
    Wong, Seng Fat
    Hu, Huijing
    Li, Le
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11