Relationship between isometric contraction intensity and muscle hardness assessed by ultrasound strain elastography

被引:34
作者
Inami, Takayuki [1 ,2 ]
Tsujimura, Toru [1 ,3 ]
Shimizu, Takuya [4 ]
Watanabe, Takemasa [4 ]
Lau, Wing Yin [1 ]
Nosaka, Kazunori [1 ]
机构
[1] Edith Cowan Univ, Sch Med & Hlth Sci, Ctr Exercise & Sports Sci Res, 270 Joondalup Dr, Joondalup, WA 6027, Australia
[2] Waseda Univ, Fac Sport Sci, Tokorozawa, Saitama, Japan
[3] Tsujimura Surg Hosp, Kariya, Aichi, Japan
[4] Chukyo Univ, Grad Sch Hlth & Sport Sci, Nagoya, Aichi, Japan
基金
日本学术振兴会;
关键词
Gastrocnemius; Strain ratio; Muscle force; Pennation angle; Muscle thickness; SHEAR-WAVE ELASTOGRAPHY; SKELETAL-MUSCLE; MEDIAL GASTROCNEMIUS; ELASTIC-MODULUS; FORCE; STIFFNESS; ARCHITECTURE; EXERCISE; TENSION; TORQUE;
D O I
10.1007/s00421-016-3528-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction Ultrasound elastography is used to assess muscle hardness or stiffness; however, no previous studies have validated muscle hardness measures using ultrasound strain elastography (SE). This study investigated the relationship between plantar flexor isometric contraction intensity and gastrocnemius hardness assessed by SE. We hypothesised that the muscle would become harder linearly with an increase in the contraction intensity of the plantar flexors. Methods Fifteen young women (20.1 +/- 0.8 years) performed isometric contractions of the ankle plantar flexors at four different intensities (25, 50, 75, 100% of maximal voluntary contraction force: MVC) at 0 degrees plantar flexion. Using SE images, the strain ratio (SR) between the muscle and an acoustic coupler (elastic modulus 22.6 kPa) placed over the skin was calculated (muscle/coupler); pennation angle and muscle thickness were measured for the resting and contracting conditions. Results SR decreased with increasing contraction intensity from rest (1.28 +/- 0.20) to 25% (0.99 +/- 0.21), 50% (0.61 +/- 0.15), 75% (0.34 +/- 0.1) and 100% MVC (0.20 +/- 0.05). SR decreased linearly (P < 0.05) with increasing MVC from rest to 75% MVC, but levelled off from 75 and 100% MVC. SR was negatively correlated with pennation angle (r = -0.80, P < 0.01) and muscle thickness ( r = -0.78, P < 0.01). Conclusion SR appears to represent muscle hardness changes in response to contraction intensity changes, in the assumption that the gastrocnemius muscle contraction intensity is proportional to the plantar flexion intensity. We concluded that gastrocnemius muscle hardness changes could be validly assessed by SR, and the force-hardness relationship was not linear.
引用
收藏
页码:843 / 852
页数:10
相关论文
共 50 条
  • [31] Sequential Changes in Posterior Shoulder Muscle Elasticity After Throwing as Assessed via Ultrasound Shear Wave Elastography
    Yamaura, Kohei
    Mifune, Yutaka
    Inui, Atsuyuki
    Nishimoto, Hanako
    Kataoka, Takeshi
    Kurosawa, Takashi
    Mukohara, Shintaro
    Niikura, Takahiro
    Kokubu, Takeshi
    Kuroda, Ryosuke
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2021, 9 (08)
  • [32] Comparative study between conventional ultrasound strain elastography and an AI-enabled elastography software in differentiating breast masses
    Kamal, Eman Faker
    Kamal, Rasha Mohamed
    Mahmoud, Ahmed M.
    Mekhaimar, Mahmoud Ibrahim
    Hanafy, Mennatallah Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2022, 53 (01)
  • [33] Comparative study between conventional ultrasound strain elastography and an AI-enabled elastography software in differentiating breast masses
    Eman Faker Kamal
    Rasha Mohamed Kamal
    Ahmed M. Mahmoud
    Mahmoud Ibrahim Mekhaimar
    Mennatallah Mohamed Hanafy
    Egyptian Journal of Radiology and Nuclear Medicine, 53
  • [34] Temporal course of perfusion in human masseter muscle during isometric contraction assessed by arterial spin labeling at 3T
    Schraml, Christina
    Schwenzer, Nina F.
    Martirosian, Petros
    Claussen, Claus D.
    Schick, Fritz
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2011, 24 (04) : 201 - 209
  • [35] Evaluation of human muscle hardness after dynamic exercise with ultrasound real-time tissue elastography: A feasibility study
    Yanagisawa, O.
    Niitsu, M.
    Kurihara, T.
    Fukubayashi, T.
    CLINICAL RADIOLOGY, 2011, 66 (09) : 815 - 819
  • [36] Effect of a 12-week Eccentric and Isometric Training in Achilles Tendinopathy on the Gastrocnemius Muscle: an Ultrasound Shear Wave Elastography Study
    Gatz, M.
    Betsch, M.
    Tingart, M.
    Michalik, R.
    Migliorini, F.
    Dirrichs, T.
    Kuhl, C.
    Quack, V.
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2020, 10 (01): : 92 - 99
  • [37] Changes in the micro-circulation of skeletal muscle due to varied isometric exercise assessed by contrast-enhanced ultrasound
    Krix, Martin
    Weber, Marc-Andre
    Kauczor, Hans-Ulrich
    Delorme, Stefan
    Krakowski-Roosen, Holger
    EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) : 110 - 116
  • [39] The relationship between estimates of puborectalis muscle shear modulus made with shear wave elastography and electromyography in healthy men
    Worman, Rachel
    Stafford, Ryan E.
    Cowley, David
    Hodges, Paul W.
    CONTINENCE, 2024, 9
  • [40] Impact of contraction intensity and ankle joint angle on calf muscle fascicle length and pennation angle during isometric and dynamic contractions
    Coenning, Corinna
    Rieg, Volker
    Siebert, Tobias
    Wank, Veit
    SCIENTIFIC REPORTS, 2024, 14 (01):