Relationship between isometric contraction intensity and muscle hardness assessed by ultrasound strain elastography

被引:34
|
作者
Inami, Takayuki [1 ,2 ]
Tsujimura, Toru [1 ,3 ]
Shimizu, Takuya [4 ]
Watanabe, Takemasa [4 ]
Lau, Wing Yin [1 ]
Nosaka, Kazunori [1 ]
机构
[1] Edith Cowan Univ, Sch Med & Hlth Sci, Ctr Exercise & Sports Sci Res, 270 Joondalup Dr, Joondalup, WA 6027, Australia
[2] Waseda Univ, Fac Sport Sci, Tokorozawa, Saitama, Japan
[3] Tsujimura Surg Hosp, Kariya, Aichi, Japan
[4] Chukyo Univ, Grad Sch Hlth & Sport Sci, Nagoya, Aichi, Japan
基金
日本学术振兴会;
关键词
Gastrocnemius; Strain ratio; Muscle force; Pennation angle; Muscle thickness; SHEAR-WAVE ELASTOGRAPHY; SKELETAL-MUSCLE; MEDIAL GASTROCNEMIUS; ELASTIC-MODULUS; FORCE; STIFFNESS; ARCHITECTURE; EXERCISE; TENSION; TORQUE;
D O I
10.1007/s00421-016-3528-2
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Introduction Ultrasound elastography is used to assess muscle hardness or stiffness; however, no previous studies have validated muscle hardness measures using ultrasound strain elastography (SE). This study investigated the relationship between plantar flexor isometric contraction intensity and gastrocnemius hardness assessed by SE. We hypothesised that the muscle would become harder linearly with an increase in the contraction intensity of the plantar flexors. Methods Fifteen young women (20.1 +/- 0.8 years) performed isometric contractions of the ankle plantar flexors at four different intensities (25, 50, 75, 100% of maximal voluntary contraction force: MVC) at 0 degrees plantar flexion. Using SE images, the strain ratio (SR) between the muscle and an acoustic coupler (elastic modulus 22.6 kPa) placed over the skin was calculated (muscle/coupler); pennation angle and muscle thickness were measured for the resting and contracting conditions. Results SR decreased with increasing contraction intensity from rest (1.28 +/- 0.20) to 25% (0.99 +/- 0.21), 50% (0.61 +/- 0.15), 75% (0.34 +/- 0.1) and 100% MVC (0.20 +/- 0.05). SR decreased linearly (P < 0.05) with increasing MVC from rest to 75% MVC, but levelled off from 75 and 100% MVC. SR was negatively correlated with pennation angle (r = -0.80, P < 0.01) and muscle thickness ( r = -0.78, P < 0.01). Conclusion SR appears to represent muscle hardness changes in response to contraction intensity changes, in the assumption that the gastrocnemius muscle contraction intensity is proportional to the plantar flexion intensity. We concluded that gastrocnemius muscle hardness changes could be validly assessed by SR, and the force-hardness relationship was not linear.
引用
收藏
页码:843 / 852
页数:10
相关论文
共 50 条
  • [1] Relationship between isometric contraction intensity and muscle hardness assessed by ultrasound strain elastography
    Takayuki Inami
    Toru Tsujimura
    Takuya Shimizu
    Takemasa Watanabe
    Wing Yin Lau
    Kazunori Nosaka
    European Journal of Applied Physiology, 2017, 117 : 843 - 852
  • [2] Biceps brachii muscle hardness assessed by a push-in meter in comparison to ultrasound strain elastography
    Mitsuyoshi Murayama
    Kazunori Nosaka
    Takayuki Inami
    Norihiro Shima
    Tsugutake Yoneda
    Scientific Reports, 10
  • [3] Biceps brachii muscle hardness assessed by a push-in meter in comparison to ultrasound strain elastography
    Murayama, Mitsuyoshi
    Nosaka, Kazunori
    Inami, Takayuki
    Shima, Norihiro
    Yoneda, Tsugutake
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [4] Reliability of Trapezius Muscle Hardness Measurement: A Comparison between Portable Muscle Hardness Meter and Ultrasound Strain Elastography
    Sawada, Tomonori
    Okawara, Hiroki
    Nakashima, Daisuke
    Iwabuchi, Shuhei
    Matsumoto, Morio
    Nakamura, Masaya
    Nagura, Takeo
    SENSORS, 2020, 20 (24) : 1 - 10
  • [5] Human muscle hardness assessment during incremental isometric contraction using transient elastography
    Gennisson, JL
    Cornu, C
    Catheline, S
    Fink, M
    Portero, P
    JOURNAL OF BIOMECHANICS, 2005, 38 (07) : 1543 - 1550
  • [6] Relationship between endometriosis and uterine cervical elasticity assessed using ultrasound strain elastography
    Xholli, Anjeza
    Molinari, Filippo
    Scovazzi, Umberto
    Londero, Ambrogio Pietro
    Perugi, Isabella
    Kratochwila, Chiara
    Cremonini, Francesca
    Cagnacci, Angelo
    ULTRASONOGRAPHY, 2024,
  • [7] Measurement of muscle architecture concurrently with muscle hardness using ultrasound strain elastography
    Chino, Kentaro
    Akagi, Ryota
    Dohi, Michiko
    Takahashi, Hideyuki
    ACTA RADIOLOGICA, 2014, 55 (07) : 833 - 839
  • [8] Comparison between ultrasonic muscle strain and electromyography during an isometric ramp contraction
    Granasen, G.
    Gronlund, C.
    Ohberg, F.
    Lindberg, F.
    Karlsson, J. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1565 - 1567
  • [9] Relationship between muscle oxygenation and electromyography activity during sustained isometric contraction
    Yamada, Eiji
    Kusaka, Takashi
    Arima, Nobuo
    Isobe, Kenichi
    Yamamoto, Tetsuji
    Itoh, Susumu
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2008, 28 (04) : 216 - 221
  • [10] The relationship between the craniofacial morphology and the fatigability of the masseter muscle during isometric contraction
    Hara, Atsushi
    Hara, Hiromi
    Uehara, Michiya
    Imamura, Nobuyoshi
    Ioi, Hideki
    Nakata, Shunsuke
    Nakasima, Akihiko
    ORTHODONTIC WAVES, 2010, 69 (03) : 85 - 91