Feasibility of grain-size analysis methods for determination of vertical hydraulic conductivity of streambeds

被引:83
作者
Song, Jinxi [1 ,2 ]
Chen, Xunhong [1 ]
Cheng, Cheng [1 ]
Wang, Deming [1 ]
Lackey, Susan [1 ]
Xu, Zongxue [3 ]
机构
[1] Univ Nebraska, Sch Nat Resources, Lincoln, NE 68583 USA
[2] Northwest Univ, Dept Environm Sci, Xian 710069, Peoples R China
[3] Beijing Normal Univ, Coll Water Sci, Beijing 100875, Peoples R China
关键词
Vertical hydraulic conductivity; Streambed; Grain-size analysis; In situ permeameter test; The Elkhorn River; AQUIFER DIFFUSIVITY; RIVER; VARIABILITY; GROUNDWATER; DEPLETION; PERMEABILITY; RESISTANCE; SYSTEM; ZONE;
D O I
10.1016/j.jhydrol.2009.06.043
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Accurate estimation of streambed vertical hydraulic conductivity (K-v) is of great importance in the analysis of water quantity exchange and solute transfer between a stream and its sediments. The paper analyzed the inaccuracy of hydraulic conductivity values of sediments derived from grain-size distribution (K-g), which were determined from eight empirical grain-size methods to represent streambed K-v. In this study, the values of K-v for a streambed were derived using falling-head standpipe permeameter tests conducted at eight study sites in the Elkhorn River, Nebraska, and the tested streambed columns were then collected for grain-size analysis by sieving. These empirical methods were used to calculate the K-g values of the streambed from grain-size distribution data of sediments. Unlike many other studies, this study verifies K-g from grain-size distribution with K-v from permeameter tests on the basis of the same samples of streambed sediments. The K-g values derived from the eight empirical methods were larger than the K-v from permeameter tests; there are five methods that give K-g values of about 3-6 times larger than these K-v. The K-g values from the Kozeny formula followed by the Hazen formula give the largest overestimation error if they are used to represent the K-v of the streambed. The USBR and Shepherd formulas generated K-g values close to K-v, but these K-g values are still larger in general than the K-v values. Moreover, the new values of coefficient C for the empirical formulas were revised so that they can be used to calculate the approximate K-v of a streambed. Among the eight methods, the ratios of the original C values to the average new C range from 1.3 to 5.9. It can be hypothesized that smaller C values must be used in the estimation of K-v for general soil samples if these empirical formulas are used to calculate K-v. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:428 / 437
页数:10
相关论文
共 44 条
[21]   Unsteady stream depletion from ground water pumping [J].
Hunt, B .
GROUND WATER, 1999, 37 (01) :98-102
[22]   A stream depletion field experiment [J].
Hunt, B ;
Weir, J ;
Clausen, B .
GROUND WATER, 2001, 39 (02) :283-289
[23]  
Hvorslev M.J., 1951, Waterways Experiment Station Bulletin, V36, P1
[24]   Measuring methods for groundwater - surface water interactions: a review [J].
Kalbus, E. ;
Reinstorf, F. ;
Schirmer, M. .
HYDROLOGY AND EARTH SYSTEM SCIENCES, 2006, 10 (06) :873-887
[25]  
Kasenow M., 2002, Determination of Hydraulic Conductivity from Grain Size Analysis
[26]  
KEECH CF, 1964, 1779E US GEOL SURV
[27]   Measuring the hydraulic, conductivity of shallow submerged sediments [J].
Kelly, SE ;
Murdoch, LC .
GROUND WATER, 2003, 41 (04) :431-439
[28]   Design of a light-oil piezomanometer for measurement of hydraulic head differences and collection of groundwater samples [J].
Kennedy, Casey D. ;
Genereux, David P. ;
Corbett, D. Reide ;
Mitasova, Helena .
WATER RESOURCES RESEARCH, 2007, 43 (09)
[29]   Effect of sampling density and design on estimation of streambed attributes [J].
Kennedy, Casey D. ;
Genereux, David P. ;
Mitasova, Helena ;
Corbett, D. Reide ;
Leahy, Scott .
JOURNAL OF HYDROLOGY, 2008, 355 (1-4) :164-180
[30]   Comparison of instream methods for measuring hydraulic conductivity in sandy streambeds [J].
Landon, MK ;
Rus, DL ;
Harvey, FE .
GROUND WATER, 2001, 39 (06) :870-885