Primary Tendon Sheath Enlargement and Reconstruction in Zone 2: An In Vitro Biomechanical Study on Tendon Gliding Resistance

被引:5
作者
Bunata, Robert E.
Kosmopoulos, Victor
Simmons, Sara
Tayag, Tristan J.
Roso, Matthew
Carlson, Heather
机构
[1] Univ N Texas Hlth Sci Ctr, Bone & Joint Res Ctr, Dept Orthopaed Surg, Ft Worth, TX USA
[2] John Peter Smith Hosp, Dept Orthopaed Surg, Ft Worth, TX 76104 USA
[3] Texas Christian Univ, Dept Engn, Ft Worth, TX 76129 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2009年 / 34A卷 / 08期
关键词
Flexor tendon injuries; flexor tendon sheath; gliding resistance; sheath and pulleys; zone; 2; FLEXOR DIGITORUM SUPERFICIALIS; PULLEY EXCISION; PARTIAL A2; ONE SLIP; REPAIR; INTEGRITY; MANAGEMENT; RESECTION; INCISION; CHICKEN;
D O I
10.1016/j.jhsa.2009.05.005
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To investigate our hypothesis that primary pulley enlargement and repair using an extensor retinaculum graft will reduce tendon repair gliding resistance. The benefit of pulley enlargement has been tested in experimental animals, but its effect on gliding resistance in vitro using human fingers is not known. Methods In vitro gliding resistance in the proximal tendon sheaths (A1 through A3) was measured and compared in 7 cadaver fingers using the method of Uchiyama and colleagues at a fixed 50 degrees over the proximal sheath under 3 conditions: (1) intact tendons with intact proximal sheath; (2) laceration and 2-strand core plus running epitenon repair of the tendons with intact sheath; and (3) repaired tendons with enlargement of the A2 pulley and adjacent proximal sheath by incision and repair with an extensor retinacular graft. Results were analyzed statistically. Results Gliding resistance increased from an average of 0.44 N +/- 0.07 in the intact condition to an average of 1.51 N +/- 0.23 (a mean increase of 243%) when the tendons were cut and repaired. Enlarging the proximal sheath by sheath incision and graft repair reduced the gliding resistance from the repair condition to 1.04 N +/- 0.15 (a mean decrease of 31%). These changes are statistically significant. Conclusions In vitro, repaired tendons had a greater resistance to gliding than that of the intact tendons through the proximal sheath when tested by the method of Uchiyama and colleagues. Enlargement and repair with an extensor retinacular graft of the A2 pulley and adjacent sheath significantly reduced resistance to repaired tendon gliding. These findings support further investigation into the concept that primary pulley enlargement may improve tendon function after repair. (J Hand Surg 2009;34A:1436-1443. Copyright (C) 2009 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:1436 / 1443
页数:8
相关论文
共 40 条
[1]  
Amadio Peter C, 2005, J Hand Ther, V18, P112, DOI 10.1197/j.jht.2005.01.005
[2]   Venting or partial lateral release of the A2 and A4 pulleys after repair of zone 2 flexor tendon injuries [J].
Ben, IK ;
Elliot, D .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (05) :649-654
[3]  
Boyer Martin I, 2003, Instr Course Lect, V52, P137
[4]   Resistance to motion of flexor tendons and digital edema:: An in vivo study in a chicken model [J].
Cao, Yi ;
Tang, Jin Bo .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (10) :1645-1651
[5]   FLEXOR TENDON-PULLEY INTERACTION AFTER TENDON REPAIR - A BIOMECHANICAL STUDY [J].
COERT, JH ;
UCHIYAMA, S ;
AMADIO, PC ;
BERGLUND, LJ ;
AN, KN .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1995, 20B (05) :573-577
[6]   ANATOMY OF THE FINGER FLEXOR TENDON SHEATH AND PULLEY SYSTEM [J].
DOYLE, JR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1988, 13A (04) :473-484
[7]   Primary flexor tendon repair - Operative repair, pulley management and rehabilitation [J].
Elliot, D .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (06) :507-513
[8]   DYNAMIC ANALYSIS OF PROFUNDUS TENDON FUNCTION [J].
GREENWALD, D ;
SHUMWAY, S ;
ALLEN, C ;
MASS, D .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (04) :626-635
[9]   FASCIA PATCH GRAFT FOR A DIGITAL FLEXOR SHEATH DEFECT OVER PRIMARY TENDON REPAIR IN THE CHICKEN [J].
KESSLER, FB ;
EPSTEIN, MJ ;
LANNIK, D ;
MAHER, D ;
PAPPU, S .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1986, 11A (02) :241-245
[10]  
Lister G, 1985, Hand Clin, V1, P85