SPECT-CT Improves Detection of Small Peritoneal Fistula

被引:13
作者
Farid, Karim [1 ,2 ,3 ,5 ]
Guyot, Martine
Jeandot, Roseline [3 ]
Durieux, Murielle [3 ]
Allard, Michele [2 ,3 ]
Fernandez, Philippe [3 ,4 ]
机构
[1] Hop Pellegrin, CHU Bordeaux, Dept Nucl Med, F-33076 Bordeaux, France
[2] CNRS, UMR 5231, F-33076 Bordeaux, France
[3] Univ Bordeaux 2, F-33076 Bordeaux, France
[4] INSERM, U577, F-33076 Bordeaux, France
[5] Hop Hotel Dieu, APHP, Dept Nucl Med, F-75181 Paris, France
关键词
SPECT-CT; peritoneal fistula; DIALYSIS;
D O I
10.1097/RLU.0b013e3181b06a97
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 51-year-old woman on peritoneal dialysis for chronic renal failure underwent laparotomy for kidney transplant. One month later, painful subcutaneous edema was observed within the abdominal wall especially apparent in the standing position. A peritoneal fistula was suspected. Peritoneal scintigraphy was performed after infusion of Tc-99m sulfur colloid into the peritoneal cavity followed by SPECT/CT. Tracer uptake was observed between the peritoneal cavity and the subcutaneous space suggesting a postsurgical peritoneal fistula. On static images, the origin of the slight uptake was difficult to determine and could be due to the presence of Tc-99m in the peritoneal catheter that projects into this area. SPECT/CT improved detection of a small peritoneal fistulas.
引用
收藏
页码:634 / 635
页数:2
相关论文
共 8 条
[1]   Additional Benefit of SPECT-CT in Investigating Heel Pain [J].
Breunung, Nina ;
Barwick, Tara ;
Fernando, Rashika ;
Gnanasegaran, Gopinath ;
Vijayanathan, Sanjay ;
Hosahalli, Mohan ;
Fogelman, Ignac .
CLINICAL NUCLEAR MEDICINE, 2008, 33 (10) :705-706
[2]  
Çakir B, 2008, DIAGN INTERV RADIOL, V14, P212
[3]   Subarachnoid-pleural fistula complicating thoracoscopy - Value of In-111 DTPA myeloscintigraphy [J].
Fernandez, P ;
Guyot, M ;
Mangione, P ;
Valli, N ;
Basse-Cathalinat, B ;
Ducassou, D .
CLINICAL NUCLEAR MEDICINE, 1999, 24 (12) :985-986
[4]   Demonstration of subclinical inguinal hernia by peritoneal scintigraphy [J].
Gupta, SM ;
Bagga, S ;
Gelfman, N ;
Margules, R .
CLINICAL NUCLEAR MEDICINE, 1997, 22 (06) :409-410
[5]   SPECT/CT of axillofemoral graft infection [J].
Lee, Allen ;
Biggs, Heather ;
Chen, Stephanie ;
Urriola, Nicolas ;
Aggarwal, Smeer ;
Al-Gailani, Hashim ;
Mansberg, Robert .
CLINICAL NUCLEAR MEDICINE, 2008, 33 (05) :333-334
[6]   Persistent aseptic meningitis due to post-surgical spinal CSF leakage:: value of fused 111mIn-DTPA SPECT-CT cisternography [J].
Slart, RHJA ;
Koopmans, KP ;
Gunneweg, P ;
Luijckx, GJ ;
de Jong, BM .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (07) :856-856
[7]   Urinary leak after renal transplantation proven by SPELT-CT imaging [J].
Talanow, Roland ;
Neumann, Donald ;
Brunken, Richard ;
Bybel, Bohdan ;
Wu, Guiyun .
CLINICAL NUCLEAR MEDICINE, 2007, 32 (11) :883-885
[8]  
WALKER JV, 1988, J NUCL MED, V29, P1596