摘要
Objectives: The influence of prosthesis-patient mismatch on outcome after aortic valve replacement is controversial. This study analyzed the impact of prosthesis-patient mismatch on survival, the extent of left ventricular mass, and physical capacity after replacement with a small-size prosthesis. Patients and Methods: A total of 157 patients who underwent valve replacement for pure aortic stenosis were reviewed. Late mortality, morbidity, left ventricular mass regression, transprosthetic gradient at rest and after exercise, exercise capacity, and occurrence of arrhythmias were evaluated. Results: Prosthesis-patient mismatch, defined as an indexed effective orifice area of 0.75 cm(2)/m(2) or more, occurred in 96 (61.1%) patients and had no significant impact on early and late mortality. The only independent predictor of mortality was age greater than 65 years. At follow-up, multivariate analysis of prosthetic gradient at rest of 35 mm Hg end exercise capacity or more revealed that both these evidences were associated with high left ventricular mass (P < .001), female gender (P < .001), and follow-up time (P< .001). Arrhythmias occurred during exercise in 34.1% of patients (40/117). Multivariate analysis of occurrence of arrhythmias revealed that they were associated with high mean transprosthetic gradients: values of 50 mm Hg or more during exercise had 95% sensitivity and 72% specificity for predicting arrhythmias. Conclusion: Prosthesis-patient mismatch failed to demonstrate any significant impact on early and late mortality and morbidity and in left ventricular mass regression. High transprosthetic gradients influence exercise capacity and occurrence of arrhythmias.
引用
收藏
页码:632 / 638
页数:7
相关论文
共 50 条
  • [21] Prosthesis-Patient Mismatch After Aortic Valve Replacement: Is It Time for a Redefinition?
    Mannacio, Vito
    De Amicis, Vincenzo
    Vosa, Carlo
    ANNALS OF THORACIC SURGERY, 2014, 97 (04) : 1482 - 1482
  • [22] Figure of eight suture technique in aortic valve replacement decreases prosthesis-patient mismatch
    Rasheed, Nabeel F.
    Stonebraker, Corinne
    Li, Zhaozhi
    Siddiqi, Umar
    Lee, Andy C. H.
    Li, Willa
    Lupo, Sydney
    Cruz, Jennifer
    Cohen, William G.
    Staub, Cathy
    Rodgers, Daniel
    Myren, Mark
    Combs, Pamela
    Jeevanandam, Valluvan
    Hibino, Narutoshi
    JOURNAL OF CARDIOTHORACIC SURGERY, 2023, 18 (01)
  • [23] Patient and procedure selection for the prevention of prosthesis-patient mismatch following aortic valve replacement
    Pibarot, Philippe
    Clavel, Marie-Annick
    Dahou, Abdellaziz
    EUROINTERVENTION, 2015, 11 : W106 - W109
  • [24] Impact of Measured and Predicted Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Guthoff, Henning
    Abdel-Wahab, Mohamed
    Kim, Won-Keun
    Witberg, Guy
    Wienemann, Hendrik
    Thurow, Maria
    Shamekhi, Jasmin
    Eckel, Clemens
    von der Heide, Ina
    Veulemans, Verena
    Landt, Martin
    Barbanti, Marco
    Finkelstein, Ariel
    Schewel, Jury
    Van Mieghem, Nicolas
    Adrichem, Rik
    Toggweiler, Stefan
    Rheude, Tobias
    Nombela-Franco, Luis
    Amat-Santos, Ignacio J.
    Ruile, Philipp
    Estevez-Loureiro, Rodrigo
    Bunc, Matjaz
    Branca, Luca
    De Backer, Ole
    Tarantini, Giuseppe
    Mylotte, Darren
    Arzamendi, Dabit
    Pauly, Markus
    Bleiziffer, Sabine
    Renker, Matthias
    Al-Kassou, Baravan
    Mollmann, Helge
    Ludwig, Sebastian
    Zeus, Tobias
    Tamburino, Corrado
    Schmidt, Tobias
    Rueck, Andreas
    von Stein, Philipp
    Thiele, Holger
    Abdelhafez, Ahmed
    Adam, Matti
    Baldus, Stephan
    Rudolph, Tanja
    Mauri, Victor
    JACC-CARDIOVASCULAR INTERVENTIONS, 2024, 17 (22) : 2626 - 2635
  • [25] Aortic valve replacement and prosthesis-patient mismatch in the era of trans-catheter aortic valve implantation
    Morita, Shigeki
    GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2016, 64 (08) : 435 - 440
  • [26] Aortic Valve Prosthesis-Patient Mismatch in a Patient Undergoing Redo Mitral Valve Replacement for Infective Endocarditis
    Lahori, Anna
    Frogel, Jonathan
    Augoustides, John G.
    Patel, Prakash A.
    Vernick, William J.
    Gutsche, Jacob T.
    Feinman, Jared W.
    Patel, Saumil
    Munroe, Ray
    MacKay, Emily J.
    Weiss, Stuart J.
    Dwarakanath, Sanjay
    Sheu, Richard D.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (06) : 2802 - 2809
  • [27] Impact of different values of prosthesis-patient mismatch on outcome in male patients with aortic valve replacement
    Mannacio, Vito A.
    Mannacio, Luigi
    Antignano, Anita
    Pinna, Giovanni B.
    Giordano, Raffaele
    Mottola, Michele
    Iannelli, Gabriele
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2017, 18 (05) : 366 - 373
  • [28] Hemodynamic and Clinical Impact of Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Implantation
    Ewe, See Hooi
    Muratori, Manuela
    Delgado, Victoria
    Pepi, Mauro
    Tamborini, Gloria
    Fusini, Laura
    Klautz, Robert J. M.
    Gripari, Paola
    Bax, Jeroen J.
    Fusari, Melissa
    Schalij, Martin J.
    Marsan, Nina Ajmone
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1910 - 1918
  • [29] Impact of prosthesis-patient mismatch on mitral regurgitation after aortic valve replacement
    Unger, P.
    Magne, J.
    Eynden, F. Vanden
    Plein, D.
    Van Camp, G.
    Pasquet, A.
    Cosyns, B.
    Dedobbeleer, C.
    Lancellotti, P.
    HEART, 2010, 96 (20) : 1627 - 1632
  • [30] Myocardial metabolism and diastolic function after aortic valve replacement for aortic stenosis: influence of patient-prosthesis mismatch
    Mannacio, Vito
    Di Tommaso, Luigi
    Stassano, Paolo
    De Amicis, Vincenzo
    Vosa, Carlo
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (02) : 316 - 321