Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: A further aspect after aortic valve replacement

被引:17
|
作者
Mannacio, Vito Antonio [1 ]
De Amicis, Vincenzo [1 ]
Di Tommaso, Luigi [1 ]
Iorio, Francesco [1 ]
Vosa, Carlo [1 ]
机构
[1] Univ Naples Federico II, Dept Cardiac Surg, Naples, Italy
关键词
LEFT-VENTRICULAR HYPERTROPHY; LONG-TERM SURVIVAL; HEART-FAILURE; IMPACT; MORTALITY; STENOSIS; SIZE; DYSFUNCTION; MORBIDITY;
D O I
10.1016/j.jtcvs.2009.01.009
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The influence of prosthesis-patient mismatch on outcome after aortic valve replacement is controversial. This study analyzed the impact of prosthesis-patient mismatch on survival, the extent of left ventricular mass, and physical capacity after replacement with a small-size prosthesis. Patients and Methods: A total of 157 patients who underwent valve replacement for pure aortic stenosis were reviewed. Late mortality, morbidity, left ventricular mass regression, transprosthetic gradient at rest and after exercise, exercise capacity, and occurrence of arrhythmias were evaluated. Results: Prosthesis-patient mismatch, defined as an indexed effective orifice area of 0.75 cm(2)/m(2) or more, occurred in 96 (61.1%) patients and had no significant impact on early and late mortality. The only independent predictor of mortality was age greater than 65 years. At follow-up, multivariate analysis of prosthetic gradient at rest of 35 mm Hg end exercise capacity or more revealed that both these evidences were associated with high left ventricular mass (P < .001), female gender (P < .001), and follow-up time (P< .001). Arrhythmias occurred during exercise in 34.1% of patients (40/117). Multivariate analysis of occurrence of arrhythmias revealed that they were associated with high mean transprosthetic gradients: values of 50 mm Hg or more during exercise had 95% sensitivity and 72% specificity for predicting arrhythmias. Conclusion: Prosthesis-patient mismatch failed to demonstrate any significant impact on early and late mortality and morbidity and in left ventricular mass regression. High transprosthetic gradients influence exercise capacity and occurrence of arrhythmias.
引用
收藏
页码:632 / 638
页数:7
相关论文
共 50 条
  • [1] Predictors and Outcomes of Prosthesis-Patient Mismatch After Aortic Valve Replacement
    Dayan, Victor
    Vignolo, Gustavo
    Soca, Gerardo
    Paganini, Juan Jose
    Brusich, Daniel
    Pibarot, Philippe
    JACC-CARDIOVASCULAR IMAGING, 2016, 9 (08) : 924 - 933
  • [2] Prosthesis-Patient Mismatch After Transcatheter Aortic Valve Replacement
    Herrmann, Howard C.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (21) : 2183 - 2185
  • [3] Impact of prosthesis-patient mismatch on early haemodynamic status after aortic valve replacement
    Kindo, Michel
    Minh, Tam Hoang
    Perrier, Stephanie
    Petit-Eisenmann, Helene
    Bentz, Jonathan
    Cristinar, Mircea
    Ajob, Gharib
    Collange, Olivier
    Mazzucotelli, Jean-Philippe
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2017, 24 (01) : 48 - 54
  • [4] The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement
    Fallon, John M.
    DeSimone, Joseph P.
    Brennan, J. Matthew
    O'Brien, Sean
    Thibault, Dylan P.
    DiScipio, Anthony W.
    Pibarot, Philippe
    Jacobs, Jeffrey P.
    Malenka, David J.
    Clarizia, Nadia A.
    Ruel, Marc
    ANNALS OF THORACIC SURGERY, 2018, 106 (01) : 14 - 23
  • [5] Prosthesis-Patient Mismatch After "High-Risk" Aortic Valve Replacement
    Popma, Jeffrey J.
    Khabbaz, Kamal
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (13) : 1335 - 1338
  • [6] Prosthesis-Patient Mismatch in the Transcatheter Aortic Valve Replacement Era
    Tuzcu, E. Murat
    Oezkan, Alper
    Kapadia, Samir R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (18) : 1919 - 1922
  • [7] Overcoming prosthesis-patient mismatch with transcatheter aortic valve replacement
    Grubb, Kendra J.
    Tom, Stephanie K.
    Sultan, Ibrahim
    Sa, Michel Pompeu
    ANNALS OF CARDIOTHORACIC SURGERY, 2024, 13 (03) : 236 - 243
  • [8] Prosthesis-patient mismatch in transcatheter aortic valve replacement
    Grubb, Kendra J.
    Kalra, Kanika
    Tom, Stephanie K.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2025, 72 : 31 - 33
  • [9] The impact of prosthesis-patient mismatch after aortic valve replacement varies according to age at operation
    Price, Joel
    Toeg, Hadi
    Lam, Buu-Khanh
    Lapierre, Harry
    Mesana, Thierry G.
    Ruel, Marc
    HEART, 2014, 100 (14) : 1099 - 1106
  • [10] Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis
    Jilaihawi, Hasan
    Chin, Derek
    Spyt, Tomasz
    Jeilan, Mohamed
    Vasa-Nicotera, Mariuca
    Bence, Johan
    Logtens, Elaine
    Kovac, Jan
    EUROPEAN HEART JOURNAL, 2010, 31 (07) : 857 - 864