The Odds Ratio Product (An Objective Sleep Depth Measure): Normal Values, Repeatability, and Change With CPAP in Patients With OSA

被引:18
|
作者
Penner, Charles Gerhard [1 ,2 ,3 ]
Gerardy, Bethany [2 ]
Ryan, Rob [3 ]
Williams, Mark [2 ]
机构
[1] Univ Manitoba, Winnipeg, MB, Canada
[2] Cerebra Hlth Inc, Winnipeg, MB, Canada
[3] RANA Resp Care Grp, Brandon, MB, Canada
来源
JOURNAL OF CLINICAL SLEEP MEDICINE | 2019年 / 15卷 / 08期
关键词
EEG spectral analysis; biomarkers; OSA; home sleep apnea test; OSA-PAP therapy; POSITIVE AIRWAY PRESSURE; RAPID-EYE-MOVEMENT; NIGHT;
D O I
10.5664/jcsm.7812
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Objectives: The Odds Ratio Product (ORP) is an objective measure of sleep depth using the relationships of the powers of different electroencephalogram (EEG) frequencies in a single index. The range of the ORP is 0 (deeply asleep) to 2.5 (fully awake). This investigation seeks to elucidate normal values of non-rapid eye movement ORP (ORPNR) in healthy individuals, repeatability of the measure, and the change in ORPNR following continuous positive airway pressure (CPAP) treatment. Methods: Healthy individuals underwent a home sleep apnea test (HSAT) with EEG followed 1 week later by EEG alone. Another cohort with OSA underwent baseline HSAT with EEG followed by a second EEG study approximately 4 weeks into treatment with CPAP. Results: Thirty-eight healthy individuals completed the protocol (mean age of 34.9 +/- 7.4 years, Epworth Sleepiness Scale score 3.6 +/- 2.4, Insomnia Severity Index score 2.0 +/- 1.6 and Functional Outcomes of Sleep Questionnaire - shorter version score 19 +/- 1.2). The mean ORPNR for all nights was 0.52 +/- 0.13. The difference between the first night and the second night was 0.024 +/- 0.17 (not significant). The intraclass correlation coefficient was 0.525, suggesting only moderate agreement between the first and second nights. The normal value for ORPNR in healthy individuals is <= 0.78 units using two standard deviations as the cutoff. Forty participants completed the OSA protocol (mean age 49 +/- 11 years, body mass index 35 +/- 6 kg/m(2), apnea-hypopnea index 33.5 +/- 28.4 events/h). The mean pre-CPAP ORPNR was 0.69 +/- 0.24 and the mean post-CPAP ORPNR was 0.57 +/- 0.22 (P = .02). Conclusions: The ORPNR proves to have significant variability from night to night in healthy individuals. ORPNR objectively improves following CPAP treatment, providing further evidence that it measures sleep depth.
引用
收藏
页码:1155 / 1163
页数:9
相关论文
共 15 条
  • [1] NORMAL VALUES AND REPEATABILITY OF A NOVEL SLEEP DEPTH SCALE; THE ODDS RATIO PRODUCT
    Penner, C.
    Gerardy, B.
    Williams, M.
    SLEEP, 2018, 41 : A121 - A122
  • [2] HOW OBJECTIVE SLEEP QUALITY WITH ODDS RATIO PRODUCT DIFFERS BY DIAGNOSIS OF COMISA, OSA, AND INSOMNIA
    Tomson, Heather
    Bender, Amy
    Lambing, Kari
    Guadagni, Veronica
    SLEEP, 2023, 46 : A235 - A235
  • [3] Odds Ratio Product of Sleep EEG as a Continuous Measure of Sleep State
    Younes, Magdy
    Ostrowski, Michele
    Soiferman, Marc
    Younes, Henry
    Younes, Mark
    Raneri, Jill
    Hanly, Patrick
    SLEEP, 2015, 38 (04) : 641 - 654
  • [4] ODDS RATIO PRODUCT AS A MEASURE OF SLEEP DEPTH DURING REM SLEEP: EFFECTS ON REM DURATION AND REM SLEEP FRAGMENTATION
    Mazzotti, D. R.
    Younes, M.
    SLEEP, 2020, 43 : A20 - A20
  • [5] ODDS RATIO PRODUCT: A MEASURE OF SLEEP HOMEOSTASIS FOLLOWING PROLONGED WAKEFULNESS
    Kuna, S. T.
    Tanayapong, P.
    Maislin, G.
    Staley, B.
    Pack, F. M.
    Pack, A., I
    Younes, M.
    SLEEP, 2018, 41 : A83 - A83
  • [6] IMPROVEMENT IN SLEEP DEPTH ON CPAP IS RELATED TO ODDS-RATIO-PRODUCT (ORP) TYPE AND APNEA-HYPOPNEA-INDEX AT BASELINE
    Guadagni, Veronica
    Lambing, Kari
    Gottschalk, Genevieve
    Gerardy, Bethany
    Bender, Amy
    Baddeley, Jane
    Younes, Magdy
    Gottschalk, Raymond
    SLEEP, 2024, 47 : A249 - A249
  • [7] A COMPARISON OF THE EFFECTS OF GABOXADOL AND SLEEP RESTRICTION ON SLEEP DEPTH ASSESSED BY THE ODDS-RATIO-PRODUCT
    Walsh, J. K.
    Schweitzer, P. K.
    Griffin, K. S.
    Younes, M.
    SLEEP, 2018, 41 : A3 - A4
  • [8] ASSESSMENT OF SLEEP DEPTH AND PROPENSITY DURING SLEEP RESTRICTION USING THE ODDS-RATIO-PRODUCT
    Schweitzer, P. K.
    Griffin, K. S.
    Younes, M.
    Walsh, J. K.
    SLEEP, 2018, 41 : A57 - A58
  • [9] MEASURING SLEEP DEPTH WITH ODDS RATIO PRODUCT (ORP) AND IN-EAR EEG EARBUDS
    Meier, Elias
    Melnykowycz, Mark
    Duke, Guy
    Du Toit, Wadda
    Lambing, Kari
    Mozzini, Federica
    Guadagni, Veronica
    SLEEP, 2024, 47
  • [10] THE ASSOCIATION OF ELECTRONIC DEVICE USE BEFORE BEDTIME ON OBJECTIVE SLEEP QUALITY MEASURED WITH ODDS RATIO PRODUCT
    Lambing, Kari
    Bender, Amy
    SLEEP, 2023, 46 : A86 - A86