Schiff bases as cadmium(II) selective ionophores in polymeric membrane electrodes

被引:194
作者
Gupta, V. K. [1 ]
Singh, A. K. [1 ]
Gupta, Barkha [1 ]
机构
[1] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
cadmium selective electrode; poly(vinylchloride) membranes; Schiff base; potentiometry and ion-selective electrodes;
D O I
10.1016/j.aca.2006.10.039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The construction and performance characteristics of polymeric membrane electrodes based on two neutral ionophores, N,N'-[bis(pyridm-2-yl)formylidene] butane- 1,4-diamine (SI) and N-(2-pyridinylmethylene)-1,2-benzenediamine (S-2) for quantification of cadmium ions, are described. The influences of membrane compositions on the potentiometric response of the electrodes have been found to substantially improve the performance characteristics. The best performance was obtained with the electrode having a membrane composition (w/w) of (SI) (2.15%):PVC (32.2%):oNPOE (64.5%):KTpClPl3 (1.07%). The proposed electrode exhibits Nernstian response in the concentration range of 7.9 x 10(-8) to 1.0 x 10(-1) M Cd2+, with limit of detection 5.0 x 10(-8) M, performs satisfactorily over wide pH range (2.0-8.0) with a fast response time (10 s). The sensor has been found to work satisfactorily in partially non-aqueous media up to 30% (v/v) content of methanol, ethanol and acetonitrile and could be used for a period of 2 months. The analytical usefulness of the proposed electrode has been evaluated by its application in the determination of cadmium in real samples. The practical utility of the membrane electrode has also been observed in the presence of surfactants. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:340 / 348
页数:9
相关论文
共 50 条
[1]   Novel solid-state cadmium ion-selective electrodes based on its tetraiodo- and tetrabromo-ion pairs with cetylpyridinium [J].
Abbas, MN ;
Zahran, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 576 (02) :205-213
[2]  
[Anonymous], ELECTROANALYSIS
[3]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[4]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[5]   Selectivity of liquid membrane ion-selective electrodes [J].
Bakker, E .
ELECTROANALYSIS, 1997, 9 (01) :7-12
[6]   OPTIMUM COMPOSITION OF NEUTRAL CARRIER BASED PH ELECTRODES [J].
BAKKER, E ;
XU, AP ;
PRETSCH, E .
ANALYTICA CHIMICA ACTA, 1994, 295 (03) :253-262
[7]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[8]   Cadmium bioavailability and speciation using the permeation liquid membrane [J].
Bayen, Stephane ;
Worms, Isabelle ;
Parthasarathy, Nalini ;
Wilkinson, Kevin ;
Buffle, Jacques .
ANALYTICA CHIMICA ACTA, 2006, 575 (02) :267-273
[9]   SUITABLE ION-SELECTIVE SENSORS FOR LEAD AND CADMIUM ANALYSIS [J].
BORRACCINO, A ;
CAMPANELLA, L ;
SAMMARTINO, MP ;
TOMASSETTI, M ;
BATTILOTTI, M .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :535-539
[10]   TRANSDUCTION OF SELECTIVE RECOGNITION OF HEAVY-METAL IONS BY CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS (CHEMFETS) [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10573-10582