Detection and characterization of focal hepatic lesions by T2-weighted imaging: comparison of navigator-triggered turbo spin-echo, breath-hold turbo spin-echo, and HASTE sequences

被引:3
|
作者
Lee, Ho Yun [1 ,2 ]
Lee, Jeong Min [1 ,2 ]
Kim, Se Hyung [1 ,2 ]
Shin, Kyung Sook [3 ]
Lee, Jae Young [1 ,2 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul Natl Univ Hosp,Clin Res Inst, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul Natl Univ Hosp,Clin Res Inst, Seoul 110744, South Korea
[3] Chungnam Natl Univ, Dept Radiol, Taejon, South Korea
关键词
Liver; Neoplasms; Magnetic resonance (MR); Comparative studies; Pulse sequences; PULSE SEQUENCES; T2-WEIGHTED MRI; HALF-FOURIER; CIRRHOTIC LIVER; CONTRAST; IMAGES; MASSES;
D O I
10.1016/j.clinimag.2008.10.031
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study is to evaluate the diagnostic performance of T-2-weighted (T-2-w) images obtained using navigator-triggered turbo spin-echo (TSE), breath-hold TSE (BH-TSE), and BH haft-Fourier single-shot TSE sequences for the detection and characterization of focal hepatic lesions. Two blinded reviewers independently analyzed three types of T-2-w image sets totaling 86 solid and 75 nonsolid lesions in 59 patients. Receiver operating characteristic curves were established to analyze reviewer and sequence results. Crown Copyright (C) 2009 Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:281 / 288
页数:8
相关论文
共 50 条
  • [21] Fat-suppressed T2-weighted MR imaging of hepatocellular carcinoma and metastases: Comparison of conventional spin-echo, fast spin-echo, and echoplanar pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Itoh, K
    Hori, M
    Inaba, Y
    Kondo, H
    Yokoyama, R
    Nakamura, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1999, 10 (01): : 25 - 32
  • [22] The value of respiratory triggered T2-weighted turbo spin-echo imaging of the liver using a phased array coil
    Namimoto, T
    Yamashita, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 655 - 662
  • [24] Breath-hold fast recovery fast spin echo versus conventional non-breath-hold fast spin echo T2-weighted MR imaging of focal liver lesions
    Tseng, GY
    Thng, CH
    Wong, EH
    Tan, AGS
    Suman, P
    Quek, ST
    Ho, JTS
    Khoo, JKB
    Ooi, LLPJ
    Chow, PKH
    Chung, YFA
    Teh, CSC
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2003, 32 (04) : 450 - 454
  • [25] CARDIAC ABNORMALITIES - ASSESSMENT WITH T2-WEIGHTED TURBO SPIN-ECHO MR-IMAGING WITH ELECTROCARDIOGRAM GATING AT 0.5 T
    SEELOS, KC
    VONSMEKAL, A
    VAHLENSIECK, M
    GIESEKE, J
    REISER, M
    RADIOLOGY, 1993, 189 (02) : 517 - 522
  • [26] Comparison of dual spin echo echo planar imaging (SE_EPI), turbo spin echo with fat suppression and conventional dual spin echo sequences for T2-weighted MR imaging of focal liver lesions
    Papanikolaou, N
    Moulopoulos, LA
    Gouliamos, A
    Ispanopoulou, S
    Vlahos, L
    MAGNETIC RESONANCE IMAGING, 2000, 18 (06) : 715 - 719
  • [27] PROSPECTIVE COMPARISON OF T2-WEIGHTED FAST SPIN-ECHO, WITH AND WITHOUT FAT-SUPPRESSION, AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES IN THE UPPER ABDOMEN
    SCHWARTZ, LH
    SELTZER, SE
    TEMPANY, CMC
    SILVERMAN, SG
    PIWNICAWORMS, DR
    ADAMS, DF
    HERMAN, L
    HERMAN, LT
    HOOSHMAND, R
    RADIOLOGY, 1993, 189 (02) : 411 - 416
  • [28] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [29] Gradient- and spin-echo T2-weighted imaging for SPIO-enhanced detection and characterization of focal liver lesions
    Yoshikawa, T
    Mitchell, DG
    Hirota, S
    Ohno, Y
    Oda, K
    Maeda, T
    Fujii, M
    Sugimura, K
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 23 (05) : 712 - 719
  • [30] MRI of the regions of inner ear and cerebellopontine angle using a 3D T-2-weighted turbo spin-echo sequence: Comparison with conventional 2D T-2-weighted turbo spin-echo sequences and T-1-weighted spin-echo sequences.
    Czerny, C
    Trattnig, S
    Baumgartner, WD
    Gstottner, W
    Imhof, H
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (04): : 377 - 383