Calix[4]arenes in the partial cone conformation as ionophores in silver ion-selective electrodes

被引:21
作者
OConnor, KM
Henderson, W
ONeill, E
Arrigan, DWM
Harris, SJ
McKervey, MA
Svehla, G
机构
[1] NATL UNIV IRELAND UNIV COLL CORK,DEPT CHEM,CORK,IRELAND
[2] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
[3] QUEENS UNIV BELFAST,SCH CHEM,BELFAST BT9 5AG,ANTRIM,NORTH IRELAND
关键词
calix[4]arene; partial cone conformation; ionophore; silver-selective electrode; potentiometry; PVC membrane;
D O I
10.1002/elan.1140090410
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two calix[4]arene derivatives, in the partial cone conformation, with sulfur-containing functionalities, were tested as neutral carrier ionophores in potentiometric silver-selective electrodes of conventional membrane and membrane-coated glassy carbon electrode types. Comparison with a calix[4]arene in the cone conformation was made. The membranes were prepared using either 2-nitrophenyl octyl ether or bis(ethylhexyl)sebacate as plasticizers and potassium tetrakis(p-chlorophenyl)borate as the lipophilic salt in a poly(vinyl chloride) matrix. Both calix[4]arenes yielded electrodes of good sensitivity (approx. 47 mV dec(-1)) in the range 10(-4) - 10(-1) M and excellent selectivity [log K-Ag,K-Mn+ < -1.5] of transition, alkali and heavy metal cations, including sodium, mercury(II) and lead(II) cations. Temperature effects and reproducibility of response were determined and the interfering effects of mercury(II) and lead(II) ions on the membranes were noted. The partial cone conformation allows improved selectivity over certain cations relative to calix[4]arenes in the cone conformation.
引用
收藏
页码:311 / 315
页数:5
相关论文
共 28 条
[1]  
[Anonymous], 1989, MONOGRAPHS SUPRAMOLE
[2]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[3]  
ARNAUDNEU F, 1991, NEW J CHEM, V15, P33
[4]   CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS - A SODIUM-ION SELECTIVE SENSOR BASED ON CALIX[4]ARENE RECEPTOR MOLECULES [J].
BRUNINK, JAJ ;
HAAK, JR ;
BOMER, JG ;
REINHOUDT, DN ;
MCKERVEY, MA ;
HARRIS, SJ .
ANALYTICA CHIMICA ACTA, 1991, 254 (1-2) :75-80
[5]   SOME ALKYLPHOSPHORIC ACID-ESTERS FOR USE IN COATED-WIRE CALCIUM-SELECTIVE ELECTRODES .1. RESPONSE CHARACTERISTICS [J].
CATTRALL, RW ;
DREW, DM ;
HAMILTON, IC .
ANALYTICA CHIMICA ACTA, 1975, 76 (02) :269-277
[6]  
CATTRALL RW, 1984, ION SEL ELECTRODE R, V6, P125
[7]   ELECTROCHEMICAL PERFORMANCE, BIOCOMPATIBILITY, AND ADHESION OF NEW POLYMER MATRICES FOR SOLID-STATE ION SENSORS [J].
CHA, GS ;
LIU, D ;
MEYERHOFF, ME ;
CANTOR, HC ;
MIDGLEY, AR ;
GOLDBERG, HD ;
BROWN, RB .
ANALYTICAL CHEMISTRY, 1991, 63 (17) :1666-1672
[8]   NEW METAL CATION-SELECTIVE IONOPHORES DERIVED FROM CALIXARENES - THEIR SYNTHESES AND ION-BINDING PROPERTIES [J].
CHANG, SK ;
CHO, I .
JOURNAL OF THE CHEMICAL SOCIETY-PERKIN TRANSACTIONS 1, 1986, (02) :211-214
[9]   TRANSDUCTION OF SELECTIVE RECOGNITION OF HEAVY-METAL IONS BY CHEMICALLY MODIFIED FIELD-EFFECT TRANSISTORS (CHEMFETS) [J].
COBBEN, PLHM ;
EGBERINK, RJM ;
BOMER, JG ;
BERGVELD, P ;
VERBOOM, W ;
REINHOUDT, DN .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10573-10582
[10]   PVC MATRIX MEMBRANE ION-SELECTIVE ELECTRODES - CONSTRUCTION AND LABORATORY EXPERIMENTS [J].
CRAGGS, A ;
MOODY, GJ ;
THOMAS, JDR .
JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (08) :541-544