Measurement of morphological and physiological skin properties in aged care residents: a test-retest reliability pilot study

被引:11
作者
Rayner, Robyn [1 ,2 ,3 ]
Carville, Keryln [1 ,2 ,3 ]
Leslie, Gavin [1 ,3 ]
Dhaliwal, Satvinder S. [1 ,4 ]
机构
[1] Curtin Univ, Sch Nursing Midwifery & Paramed, GPO Box U1987, Perth, WA 6845, Australia
[2] Silver Chain Grp, Perth, WA, Australia
[3] Wound Management Innovat Cooperat Res Ctr, West End, Qld, Australia
[4] Curtin Univ, Sch Publ Hlth, Perth, WA, Australia
关键词
Aged skin; Intra-rater reliability; Non-invasive technologies; Reproducibility; Skin-properties; Test-retest; TRANSEPIDERMAL WATER-LOSS; IN-VIVO ASSESSMENT; LOW-ECHOGENIC BAND; EEMCO GUIDANCE; INTERNATIONAL GUIDELINES; QUANTITATIVE-EVALUATION; MECHANICAL-PROPERTIES; AGREEMENT; COLOR; ELASTICITY;
D O I
10.1111/iwj.12621
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
This test-retest pilot study investigated the intra-rater reliability and reproducibility of non-invasive technologies to objectively quantify morphological (colour, thickness and elasticity) and physiological (transepidermal water loss (TEWL), hydration, sebum and pH) skin properties in an aged care population. Three consecutive measurements were taken from five anatomical skin sites, with the mean of each measurement calculated. The intra-class correlation coefficient (ICC) and the standard error of measurement (SEM) were used to examine the intra-rater reliability and reproducibility of measurements. Non-invasive technologies in this study showed almost perfect reliability for ultrasound measurements of the subepidermal low echogenicity band (SLEB) (rho=0.95-0.99) and skin thickness (rho=0.95-0.99) across all sites. The ICC was substantial to almost perfect for pH (rho=0.76-0.88) and viscoelasticity (rho=0.67-0.91) across all sites. Hydration (rho=0.53-0.85) and skin retraction (rho=0.57-0.99) measurements ranged from moderate to almost perfect across all sites. TEWL and elasticity were substantial to almost perfect across four sites. Casual sebumlevels and most colour parameters showed poor ICC. The use of non-invasive technologies in this study provided an objective and reliable means for quantifying ageing skin and may offer future studies a valuable option for assessing skin tear risk.
引用
收藏
页码:420 / 429
页数:10
相关论文
共 81 条
  • [1] American Society for Testing Materials, 2009, E1164 ASTM INT
  • [2] World Medical Association Declaration of Helsinki Ethical Principles for Medical Research Involving Human Subjects
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2013, 310 (20): : 2191 - 2194
  • [3] Measurement of elasticity and transepidermal water loss rate of burn scars with the Dermalab®
    Anthonissen, Mieke
    Daly, Daniel
    Fieuws, Steffen
    Massage, Patrick
    Van Brussel, Michel
    Vranckx, Jan
    Van den Kerckhove, Eric
    [J]. BURNS, 2013, 39 (03) : 420 - 428
  • [4] An imaging colorimeter for noncontact tissue color mapping
    Balas, C
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (06) : 468 - 474
  • [5] AGING SKIN
    BOLOGNIA, JL
    [J]. AMERICAN JOURNAL OF MEDICINE, 1995, 98 : S99 - S103
  • [6] Confirmed efficacy of topical nifedipine in the treatment of facial wrinkles
    Calabro, Gabriella
    De Vita, Valerio
    Patalano, Angela
    Mazzella, Caterina
    Lo Conte, Viviana
    Antropoli, Carmine
    [J]. JOURNAL OF DERMATOLOGICAL TREATMENT, 2014, 25 (04) : 319 - 325
  • [7] Cerin E., 2014, ENCY QUALITY LIFE WE, P6318
  • [8] Comparison of ICC and CCC for assessing agreement for data without and with replications
    Chen, Chia-Cheng
    Barnhart, Huiman X.
    [J]. COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2008, 53 (02) : 554 - 564
  • [9] Dadzie OE, 2013, ETHNIC DERMATOLOGY: PRINCIPLES AND PRACTICE, P1
  • [10] Darlenski R, 2014, NON INVASIVE DIAGNOS, P353