Ultrasound-guided transient elastography and two-dimensional shear wave elastography for assessment of liver fibrosis: emphasis on technical success and reliable measurements

被引:6
作者
Lee, Jihyuk [1 ,2 ]
Kang, Hyo-Jin [1 ,2 ]
Yoon, Jeong Hee [1 ,2 ]
Lee, Jeong Min [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
[2] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul, South Korea
[3] Seoul Natl Univ, Inst Radiat Med, Med Res Ctr, 101 Daehak Ro, Seoul 03080, South Korea
关键词
Ultrasonography; Transient elastography; Shear wave elastography; Chronic liver disease; MAGNETIC-RESONANCE ELASTOGRAPHY; CHRONIC HEPATITIS-B; PERFORMANCE; STIFFNESS; CIRRHOSIS; PREDICT;
D O I
10.14366/usg.20036
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigated whether the use of ultrasound (US) guidance in transient elastography (TE) improved the technical success and reliability of liver stiffness (LS) measurements and whether 2-dimensional (2D) shear wave elastography (SWE) provided reliable LS measurements if TE measurements failed. Methods: In this prospective study, 292 participants (male:female, 189:103; median age, 60 years) with chronic liver disease (CLD) were enrolled. LS was measured via the consecutive use of conventional TE, 2D-SWE, and US-guided TE. The technical success rates and reliable LS measurement rates of the three elastography techniques were compared. The risk factors for TE failure were assessed through univariate and multivariate logistic regression models. Results: US-guided TE was associated with a higher technical success rate (281 of 292, 96.2%) and a higher reliable measurement rate (266 of 292, 91.1%) than conventional TE (technical success: 256 of 292, 87.7%; reliable measurements: 231 of 292, 79.1%; P<0.001 for both). In participants for whom conventional TE failed, 2D-SWE provided high rates of technical success (36 of 36, 100%) and reliable measurements (30 of 36, 83.3%). TE failure was associated with female sex (odds ratio [OR], 5.85; 95% confidence interval [CI], 1.30 to 26.40), severe reverberation artifacts (OR, 8.79; 95% CI, 3.93 to 19.69), and high skin-to-liver capsule depth (OR, 1.23; 95% CI, 1.09 to 1.39). Conclusion: US guidance in TE improved the technical success and reliable measurement rates in the assessment of LS in patients with CLD. In participants for whom TE failed, subsequent 2D-SWE successfully delivered reliable LS measurements.
引用
收藏
页码:217 / 227
页数:11
相关论文
共 40 条
[1]   Liver Fibrosis, but No Other Histologic Features, Is Associated With Long-term Outcomes of Patients With Nonalcoholic Fatty Liver Disease [J].
Angulo, Paul ;
Kleiner, David E. ;
Dam-Larsen, Sanne ;
Adams, Leon A. ;
Bjornsson, Einar S. ;
Charatcharoenwitthaya, Phunchai ;
Mills, Peter R. ;
Keach, Jill C. ;
Lafferty, Heather D. ;
Stahler, Alisha ;
Haflidadottir, Svanhildur ;
Bendtsen, Flemming .
GASTROENTEROLOGY, 2015, 149 (02) :389-+
[2]   Clinical Significance of US Artifacts [J].
Baad, Michael ;
Lu, Zheng Feng ;
Reiser, Ingrid ;
Paushter, David .
RADIOGRAPHICS, 2017, 37 (05) :1408-1423
[3]   Non-invasive evaluation of liver fibrosis using transient elastography [J].
Castera, Laurent ;
Forns, Xavier ;
Alberti, Alfredo .
JOURNAL OF HEPATOLOGY, 2008, 48 (05) :835-847
[4]   Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations [J].
Castera, Laurent ;
Foucher, Juliette ;
Bernard, Pierre-Henri ;
Carvalho, Francoise ;
Allaix, Daniele ;
Merrouche, Wassil ;
Couzigou, Patrice ;
de Ledinghen, Victor .
HEPATOLOGY, 2010, 51 (03) :828-835
[5]   Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: A multicenter prospective study (the FIBROSTIC study) [J].
Degos, Francoise ;
Perez, Paul ;
Roche, Bruno ;
Mahmoudi, Amel ;
Asselineau, Julien ;
Voitot, Helene ;
Bedossa, Pierre .
JOURNAL OF HEPATOLOGY, 2010, 53 (06) :1013-1021
[6]  
Dhyani M, 2010, RAD SOC N AM RSNA 96
[7]   EASL 2017 Clinical Practice Guidelines on the management of hepatitis B virus infection [J].
Lampertico P. ;
Agarwal K. ;
Berg T. ;
Buti M. ;
Janssen H.L.A. ;
Papatheodoridis G. ;
Zoulim F. ;
Tacke F. .
JOURNAL OF HEPATOLOGY, 2017, 67 (02) :370-398
[8]   Shear Wave Elastography for Evaluation of Liver Fibrosis [J].
Ferraioli, Giovanna ;
Parekh, Parth ;
Levitov, Alexander B. ;
Filice, Carlo .
JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (02) :197-203
[9]   Ultrasound in chronic liver disease [J].
Gerstenmaier J.F. ;
Gibson R.N. .
Insights into Imaging, 2014, 5 (4) :441-455
[10]   Role of two-dimensional shear wave elastography in chronic liver diseases: A narrative review [J].
Jeong, Jae Yoon ;
Cho, Young Seo ;
Sohn, Joo Hyun .
WORLD JOURNAL OF GASTROENTEROLOGY, 2018, 24 (34) :3849-3860