Box-Behnken design for the optimization of an enantioselective method for the simultaneous analysis of propranolol and 4-hydroxypropranolol by CE

被引:25
作者
Borges, Keyller Bastos [1 ]
Pupo, Monica Tallarico [2 ]
Pedro de Freitas, Luis Alexandre [2 ]
Bonato, Pierina Sueli [1 ]
机构
[1] Univ Sao Paulo, Fac Pharmaceut Sci Ribeirao Preto, Dept Chem & Phys, BR-14040903 Ribeirao Preto, Brazil
[2] Univ Sao Paulo, Fac Pharmaceut Sci Ribeirao Preto, Dept Pharmaceut Sci, BR-14040903 Ribeirao Preto, Brazil
基金
巴西圣保罗研究基金会;
关键词
4-Hydroxypropranolol; Box-Behnken design; CE; Enantioseparation; Propranolol; ENANTIOMERIC PURITY DETERMINATION; CAPILLARY-ELECTROPHORESIS; BETA-CYCLODEXTRIN; CHIRAL SELECTOR; SEPARATION; DOG; METABOLITES; ISOMERS; URINE; RAT;
D O I
10.1002/elps.200800821
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An experimental design optimization (Box-Behnken design, BBD) was used to develop a CE method for the simultaneous resolution of propranolol (Prop) and 4-hydroxypropranolol enantiomers and acetaminophen (internal standard). The method was optimized using an uncoated fused silica capillary, carboxymethyl-beta-cyclodextrin (CM-beta-CD) as chiral selector and triethylamine/phosphoric acid buffer in alkaline conditions. A BBD for four factors was selected to observe the effects of buffer electrolyte concentration, pH, CM-beta-CD concentration and voltage on separation responses. Each factor was studied at three levels: high, central and low, and three center points were added. The buffer electrolyte concentration ranged from 25 to 75 mM, the pH ranged from 8 to 9, the CM-beta-CD concentration ranged from 3.5 to 4.5%w/v, and the applied run voltage ranged from 14 to 20 W. The responses evaluated were resolution and migration time for the last peak. The obtained responses were processed by Minitab (R) to evaluate the significance of the effects and to find the optimum analysis conditions. The best results were obtained using 4%w/v CM-beta-CD in 25 mM triethylamine/H3PO4 buffer at pH 9 as running electrolyte and 17 kV of voltage. Resolution values of 1.98 and 1.95 were obtained for Prop and 4-hydroxypropranolol enantiomers, respectively. The total analysis time was around of 15 min. The BBD showed to be an adequate design for the development of a CE method, resulting in a rapid and efficient optimization of the pH and concentration of the buffer, cyclodextrin concentration and applied voltage.
引用
收藏
页码:2874 / 2881
页数:8
相关论文
共 32 条
[1]  
Assi KA, 1999, ELECTROPHORESIS, V20, P2723, DOI 10.1002/(SICI)1522-2683(19990901)20:13<2723::AID-ELPS2723>3.0.CO
[2]  
2-O
[3]   USE OF BETA-CYCLODEXTRIN POLYMER AS A CHIRAL SELECTOR IN CAPILLARY ELECTROPHORESIS [J].
ATURKI, Z ;
FANALI, S .
JOURNAL OF CHROMATOGRAPHY A, 1994, 680 (01) :137-146
[4]   Experimental design to investigate factors affecting capillary zone electrophoresis [J].
Babu, CVS ;
Chung, BC ;
Yoo, YS .
ANALYTICAL LETTERS, 2004, 37 (12) :2485-2499
[5]   BIOLOGICAL PROPERTIES OF OPTICAL ISOMERS OF PROPRANOLOL AND THEIR EFFECTS ON CARDIAC ARRHYTHMIAS [J].
BARRETT, AM ;
CULLUM, VA .
BRITISH JOURNAL OF PHARMACOLOGY, 1968, 34 (01) :43-+
[6]  
Box G., 2005, Statistics for Experimenters, VSecond
[7]  
Box G.E., 1960, Technometrics, V2, P455, DOI 10.2307/1266454
[8]  
Bruns R.E., 2006, Statistical Design-Chemometrics
[9]  
DERRINGER G, 1980, J QUAL TECHNOL, V12, P214, DOI 10.1080/00224065.1980.11980968
[10]  
EECKHAUT AV, 2006, ELECTROPHORESIS, V27, P2880