An optimal implementation strategy of the multi-function window considering the nonlinearity of its technical-environmental-economic performance by window ventilation system size

被引:12
作者
An, Jongbaek [1 ]
Hong, Taehoon [1 ]
Oh, Jeongyoon [1 ]
Jung, Woojin [1 ]
Jeong, Kwangbok [1 ]
Park, Hyo Seon [1 ]
Lee, Dong-Eun [2 ]
机构
[1] Yonsei Univ, Dept Architecture & Architectural Engn, Seoul 03722, South Korea
[2] Kyungpook Natl Univ, Sch Architecture & Civil Engn, Daegu 41566, South Korea
基金
新加坡国家研究基金会;
关键词
Multi-function window; Window ventilation system; Solar photovoltaic blind; Nonlinearity analysis; Multi-objective optimization; MULTIOBJECTIVE OPTIMIZATION MODEL; ROOFTOP PHOTOVOLTAIC SYSTEM; THERMAL COMFORT; AIR-QUALITY; ENERGY-CONSUMPTION; BUILDINGS; DESIGN; IMPACT; COST; INSULATION;
D O I
10.1016/j.buildenv.2019.106234
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To address the problems of the indoor air quality deterioration and energy consumption, this study proposed the multi-function window combined with a ventilation system and solar photovoltaic blind. In this study, multi-objective optimization for determining the optimal design of the multi-function window was conducted along with nonlinearity analysis. The main findings can be summarized as follows. First, from the technical-environmental performance's perspective, the amount of solar radiation and wind volume entering the room were found to be key factors causing nonlinearity. In particular, the total energy consumption and indoor CO2 concentration decreased whereas the predicted percentage dissatisfied deteriorated with the increasing the size of the window ventilation system. Second, from the economic performance's perspective, the absolute and relative investment values showed nonlinear relationships with the amount of electricity generated and the total energy consumption. Especially, as the window ventilation system size increased, the absolute investment value decreased due to the reduced amount of electricity generated, and the relative investment value decreased except when the energy supply was larger than the energy demand. Finally, the window ventilation system size was most suitable when it was 3-5% of the multi-function window's size according to the orientation, from a holistic view of the technical-environmental-economic performance.
引用
收藏
页数:18
相关论文
共 62 条
[1]  
[Anonymous], REG SUPP SERV
[2]  
[Anonymous], REC TRAD SYST
[3]  
[Anonymous], 2007, 15251 CSN EN COM EUR
[4]  
[Anonymous], 2020, MULTIOBJECTIVE MANAG
[5]   Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage [J].
Atthajariyakul, S ;
Leephakpreeda, T .
ENERGY AND BUILDINGS, 2004, 36 (07) :720-733
[6]   A simplified estimation model for determining the optimal rooftop photovoltaic system for gable roofs [J].
Ban, Cheolwoo ;
Hong, Taehoon ;
Jeong, Kwangbok ;
Koo, Choongwan ;
Jeong, Jaewook .
ENERGY AND BUILDINGS, 2017, 151 :320-331
[7]   Impacts of window opening grade on improving the energy efficiency of a facade in hot climates [J].
Bayoumi, Mohannad .
BUILDING AND ENVIRONMENT, 2017, 119 :31-43
[8]   Optimisation analysis of PCM-enhanced opaque building envelope components for the energy retrofitting of office buildings in Mediterranean climates [J].
Cascone, Ylenia ;
Capozzoli, Alfonso ;
Perino, Marco .
APPLIED ENERGY, 2018, 211 :929-953
[9]   Building energy performance evaluation of building integrated photovoltaic (BIPV) window with semi-transparent solar cells [J].
Chae, Young Tae ;
Kim, Jeehwan ;
Park, Hongsik ;
Shin, Byungha .
APPLIED ENERGY, 2014, 129 :217-227
[10]   Generating optimal derivative free iterative methods for nonlinear equations by using polynomial interpolation [J].
Cordero, Alicia ;
Hueso, Jose L. ;
Martinez, Eulalia ;
Torregrosa, Juan R. .
MATHEMATICAL AND COMPUTER MODELLING, 2013, 57 (7-8) :1950-1956