Comparative biomechanic performances of locked Cruciate four-strand flexor tendon repairs in an ex vivo porcine model

被引:39
作者
Croog, Alexander
Goldstein, Rachel
Nasser, Philip
Lee, Steve K.
机构
[1] NYU, Hosp Joint Dis, Dept Orthopaed Surg, New York, NY 10003 USA
[2] Mt Sinai Sch Med, Orthopaed Res Lab, New York, NY USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2007年 / 32A卷 / 02期
关键词
flexor tendon; locking suture; tendon repair; tensile strength;
D O I
10.1016/j.jhsa.2006.11.009
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To investigate the effects of 3 different locking configurations on repair strength when used in a cruciate four-strand repair. Methods: Sixty fresh porcine flexor tendons were transected and repaired with cruciate four-strand core suture repairs with 3 different locking configurations: simple locks (a modification of the Pennigton method), circle locks, and cross locks. Half of the repairs in each locking group were reinforced with a peripheral suture. The tendon repairs were subjected to linear load-to-failure testing. Outcome measures were 2-mm gap force and ultimate tensile strength. Results: The cross lock repair had significantly greater 2-mm gap force and ultimate tensile strength than the simple lock repair, both with and without a peripheral suture: The cross lock repair showed significantly greater 2-mm gap force without a peripheral suture and significantly greater ultimate tensile strength with a peripheral suture than the circle lock repair. With peripheral reinforcement, the cross lock cruciate repair had a mean 2-mm gap force of 92 N and ultimate tensile strength of 119 N. The cross lock cruciate repair consistently produced the strongest biomechanic performance in all outcome measures. Conclusions: Locking configuration influences the biomechanic performance of cruciate four-strand flexor tendon repairs. Our results suggest that the cruciate repair with cross locks is stronger than repairs with simple locks or circle locks. Whether the results of this ex vivo porcine linear model can be translated to the clinical arena is unknown, because the factors of tendon/sheath friction, tendon healing, and compromised tendon viability from the lock were not addressed.
引用
收藏
页码:225 / 232
页数:8
相关论文
共 47 条
  • [41] Urbaniak JR., 1975, AAOS S TENDON SURG H, P70
  • [42] Comparison of postoperative early active mobilization and immobilization in vivo utilising a four-strand flexor tendon repair
    Wada, A
    Kubota, H
    Miyanishi, K
    Hatanaka, H
    Miura, H
    Iwamoto, Y
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (04) : 301 - 306
  • [43] The mechanical properties of locking and grasping suture loop configurations in four-strand core suture techniques
    Wada, A
    Kubota, H
    Hatanaka, H
    Hotokezaka, S
    Miura, H
    Iwamoto, Y
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2000, 25B (06) : 548 - 551
  • [44] Increased suture embedment in tendons: An effective method to improve repair strength
    Wang, B
    Tang, JB
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2002, 27B (04) : 333 - 336
  • [45] Investigation of locking configurations for tendon repair
    Xie, RG
    Tang, JB
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2005, 30A (03): : 461 - 465
  • [46] Biomechanical studies of 3 different 6-strand flexor tendon repair techniques
    Xie, RG
    Zhang, SY
    Tang, JB
    Chen, F
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2002, 27A (04): : 621 - 627
  • [47] Mechanical strengths of tendon sutures - An in vitro comparative study of six techniques
    Zatiti, SCA
    Mazzer, N
    Barbieri, CH
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (02) : 228 - 233