Monitoring and control of TMP and feed flow rate pulsatile operations during ultrafiltration in a membrane module

被引:17
作者
Curcio, S [1 ]
Calabrò, V [1 ]
Iorio, G [1 ]
机构
[1] Univ Calabria, Dept Chem & Mat Engn, I-87030 Arcavacata Di Rende, CS, Italy
关键词
ultrafiltration; membrane fouling; pulsating operations; data acquisition; labview;
D O I
10.1016/S0011-9164(02)00415-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The aim of this paper is the presentation of a novel system for continuous monitoring of the operating variables involved in ultrafiltration process. The proposed system is based on the utilization of a data acquisition set, consisting of field point units supplied by National Instruments, connected to a Personal Computer, thus allowing UF module performance monitoring. It is, therefore, possible to continuously measure permeate flux decay and to control membrane fouling by means of a device, controlled by the PC, that is able to generate pulses on both trans-membrane pressure and feed flow rate. This device, already patented by the authors [1], is comprised by a system of electric valves that, during a standard cross-flow operation, prime, without any plant stop or any flux inversion, a "cleansing" procedure for the membrane. The main advantages related to the utilization of this device are: the improvement of both performances and efficiency of membrane cross-flow operations, its simplicity and the economy of its installation, the reduction of the dead times due to plant stops and to traditional cleaning procedures. The application of the proposed system to the BSA ultrafiltration showed a significant increase of permeate fluxes with respect to a traditional cross-flow filtration plant.
引用
收藏
页码:217 / 222
页数:6
相关论文
共 10 条
  • [1] Flux enhancement in reverse osmosis using centrifugal membrane separation
    Bergen, A
    Fyles, TM
    Lycon, DS
    Vickers, GW
    Wild, P
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2000, 176 (02) : 257 - 266
  • [2] FLUX ENHANCEMENT IN CROSS-FLOW MICROFILTRATION USING A COLLAPSIBLE-TUBE PULSATION GENERATOR
    BERTRAM, CD
    HOOGLAND, MR
    LI, H
    ODELL, RA
    FANE, AG
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1993, 84 (03) : 279 - 292
  • [3] Flux enhancement in laminar crossflow microfiltration using a collapsible-tube pulsation generator
    Hadzismajlovic, DE
    Bertram, CD
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1998, 142 (02) : 173 - 189
  • [4] Modeling of flux decline during crossflow ultrafiltration of colloidal suspensions
    Lee, Y
    Clark, MM
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1998, 149 (02) : 181 - 202
  • [5] The effect of high frequency backflushing on the microfiltration of yeast homogenate suspensions for the recovery of soluble proteins
    Levesley, JA
    Hoare, M
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1999, 158 (1-2) : 29 - 39
  • [6] MARRA F, 1999, Patent No. 990023
  • [7] CROSS-FLOW MICROFILTRATION WITH HIGH-FREQUENCY REVERSE FILTRATION
    REDKAR, SG
    DAVIS, RH
    [J]. AICHE JOURNAL, 1995, 41 (03) : 501 - 508
  • [8] REDUCTION OF MEMBRANE FOULING IN THE ULTRAFILTRATION OF BINARY PROTEIN MIXTURES
    RODGERS, VGJ
    SPARKS, RE
    [J]. AICHE JOURNAL, 1991, 37 (10) : 1517 - 1528
  • [9] EFFECT OF TRANSMEMBRANE PRESSURE PULSING ON CONCENTRATION POLARIZATION
    RODGERS, VGJ
    SPARKS, RE
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1992, 68 (1-2) : 149 - 168
  • [10] TORU Y, 1994, Patent No. 0588348