Practical tips for performing resuscitative endovascular balloon occlusion of the aorta

被引:3
作者
Chang, Sung Wook [1 ]
Ma, Dae Sung [1 ]
Chang, Ye Rim [2 ]
Kim, Dong Hun [2 ]
机构
[1] Dankook Univ Hosp, Trauma Ctr, Dept Thorac & Cardiovasc Surg, Cheonan, South Korea
[2] Dankook Univ Hosp, Trauma Ctr, Dept Trauma Surg, Cheonan, South Korea
关键词
Trauma; resuscitation; aorta; balloon occlusion;
D O I
10.1177/1024907921994422
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Hemorrhage is the leading cause of death in trauma settings. Non-compressible torso hemorrhage, which is caused by abdominopelvic and thoracic injuries, is an important cause of subsequent organ dysfunction and poor outcomes in multiple trauma patients. The management of hemodynamically unstable patients with non-compressible torso hemorrhage has changed, and the concept of damage control resuscitation has been developed in the last decades. Currently, resuscitative endovascular balloon occlusion of the aorta (REBOA) as a method of temporary stabilization is the modern evolution of bleeding control, and it is in the middle of a paradigm shift as a treatment for non-compressible torso hemorrhage. Despite its effectiveness in patients with hemorrhagic shock, the application of REBOA remains limited because of lack of experience and troubleshooting guidelines. Objectives: The aim of study was to provide useful tips for the implementing a step-by-step procedure for REBOA in various hospital settings and capabilities. Methods: We introduced REBOA procedures using a REBOA-customized 7 Fr balloon catheter through the animation models or radiography from preparation to access, catheter management, and device removal after procedure completed. Results: We have described REBOA procedures as follows: identification of the common femoral artery, arterial access for placement of a guidewire, precautions during a sheath insertion, guidewire and balloon positioning in the aorta, occlusion zones and adjustment of balloon location, REBOA strategy for extending the occlusion time, balloon deflation and removal, sheath removal, and medical records. Conclusion: We believe that the practical tips mentioned in this article will help in performing the REBOA procedure systematically and developing an effective REBOA framework.
引用
收藏
页码:165 / 173
页数:9
相关论文
共 48 条
[21]  
Kim DH, 2017, TRAUMA IMAGE PROCED, V2, P92
[22]   The utilization of resuscitative endovascular balloon occlusion of the aorta: preparation, technique, and the implementation of a novel approach to stabilizing hemorrhage [J].
Kim, Dong Hun ;
Chang, Sung Wook ;
Matsumoto, Junichi .
JOURNAL OF THORACIC DISEASE, 2018, 10 (09) :5550-5559
[23]   Efficacy of intermittent versus standard resuscitative endovascular balloon occlusion of the aorta in a lethal solid organ injury model [J].
Kuckelman, John ;
Derickson, Michael ;
Barron, Morgan ;
Phillips, Cody J. ;
Moe, Donald ;
Levine, Tiffany ;
Kononchik, Joseph P. ;
Marko, Shannon T. ;
Eckert, Matthew ;
Martin, Matthew J. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2019, 87 (01) :9-17
[24]   Using MRI to evaluate Anatomic significance of aortic bifurcation, right renal artery, and conus medullaris when locating lumbar vertebral segments [J].
Lee, CH ;
Seo, BK ;
Choi, YC ;
Shin, HJ ;
Park, JH ;
Jeon, HJ ;
Kim, KA ;
Park, CM ;
Kim, BH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) :1295-1300
[25]   Damage control interventional radiology (DCIR) in prompt and rapid endovascular strategies in trauma occasions (PRESTO): A new paradigm [J].
Matsumoto, J. ;
Lohman, B. D. ;
Morimoto, K. ;
Ichinose, Y. ;
Hattori, T. ;
Taira, Y. .
DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (7-8) :687-691
[26]   Organ ischemia during partial resuscitative endovascular balloon occlusion of the aorta: Dynamic 4D Computed tomography in swine [J].
Matsumura, Yosuke ;
Higashi, Akiko ;
Izawa, Yoshimitsu ;
Hishikawa, Shuji ;
Kondo, Hiroshi ;
Reva, Viktor ;
Oda, Shigeto ;
Matsumoto, Junichi .
SCIENTIFIC REPORTS, 2020, 10 (01)
[27]   Partial occlusion, conversion from thoracotomy, undelayed but shorter occlusion: resuscitative endovascular balloon occlusion of the aorta strategy in Japan [J].
Matsumura, Yosuke ;
Matsumoto, Junichi ;
Kondo, Hiroshi ;
Idoguchi, Koji ;
Funabiki, Tomohiro .
EUROPEAN JOURNAL OF EMERGENCY MEDICINE, 2018, 25 (05) :348-354
[28]   Fewer REBOA complications with smaller devices and partial occlusion: evidence from a multicentre registry in Japan [J].
Matsumura, Yosuke ;
Matsumoto, Junichi ;
Kondo, Hiroshi ;
Idoguchi, Koji ;
Ishida, Tokiya ;
Kon, Yuri ;
Tomita, Keisuke ;
Ishida, Kenichiro ;
Hirose, Tomoya ;
Umakoshi, Kensuke ;
Funabiki, Tomohiro .
EMERGENCY MEDICINE JOURNAL, 2017, 34 (12) :793-799
[29]  
Matsushima Kazuhide, 2019, Anesthesiol Clin, V37, P171, DOI 10.1016/j.anclin.2018.09.003
[30]   USE OF RESUSCITATIVE ENDOVASCULAR BALLOON OCCLUSION OF THE AORTA IN A HIGHLY LETHAL MODEL OF NONCOMPRESSIBLE TORSO HEMORRHAGE [J].
Morrison, Jonathan J. ;
Ross, James D. ;
Houston, Robert ;
Watson, Devin B. ;
Sokol, Kyle K. ;
Rasmussen, Todd E. .
SHOCK, 2014, 41 (02) :130-137