Distribution of Fiducial Registration Error in Rigid-Body Point-Based Registration

被引:13
作者
Moghari, Mehdi Hedjazi [2 ]
Abolmaesumi, Purang [1 ]
机构
[1] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V6T 1Z4, Canada
[2] Harvard Univ, Sch Med, Boston, MA 02215 USA
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
Fiducial localization error; fiducial registration error; inhomogeneous and anisotropic zero-mean noise; maximum likelihood; registration; target registration error; TARGET REGISTRATION;
D O I
10.1109/TMI.2009.2024208
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Rigid-body point-based registration is frequently used in computer assisted surgery to align corresponding points, or fiducials, in preoperative and intraoperative data. This alignment is mostly achieved by assuming the same homogeneous error distribution for all the points; however, due to the properties of the medical instruments used in measuring the point coordinates, the error distribution might be inhomogeneous and different for each point. In this paper, in an effort to understand the effect of error distribution in the localized points on the performed registration, we derive a closed-form solution relating the error distribution of each point with the performed registration accuracy. The solution uses maximum likelihood estimation to calculate the probability density function of registration error at each fiducial point. Extensive numerical simulations are performed to validated the proposed solution.
引用
收藏
页码:1791 / 1801
页数:11
相关论文
共 15 条
[1]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[2]  
BALACHANDRAN R, 2008, P SPIE MED IMAG VISU, V6918
[3]   Predicting error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB ;
Maurer, CR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1998, 17 (05) :694-702
[4]   The distribution of target registration error in rigid-body point-based registration [J].
Fitzpatrick, JM ;
West, JB .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (09) :917-927
[5]   CLOSED-FORM SOLUTION OF ABSOLUTE ORIENTATION USING UNIT QUATERNIONS [J].
HORN, BKP .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1987, 4 (04) :629-642
[6]  
Ma B, 2007, LECT NOTES COMPUT SC, V4792, P628
[7]   Point-based rigid-body registration using an unscented kalman filter [J].
Moghari, Mehdi Hedjazi ;
Abolmaesumi, Purang .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (12) :1708-1728
[8]  
Moghari MH, 2006, LECT NOTES COMPUT SC, V4191, P603
[9]   Distribution of Target Registration Error for Anisotropic and Inhomogeneous Fiducial Localization Error [J].
Moghari, Mehdi Hedjazi ;
Abolmaesumi, Purang .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (06) :799-813
[10]  
Moghari MH, 2008, LECT NOTES COMPUT SC, V5242, P1032, DOI 10.1007/978-3-540-85990-1_124