Determination of ascorbic acid by polypyrrole potentiometric detector in ion chromatography

被引:28
作者
Sahin, Mutlu [1 ]
Ozcan, Levent [1 ]
Usta, Betuel [1 ]
Sahin, Yuecel [1 ]
机构
[1] Anadolu Univ, Fac Sci, Dept Chem, TR-26470 Eskisehir, Turkey
关键词
Ascorbic acid; Polypyrrole; Potentiometric detection; Ion chromatography; Electrochemical polymerization; PENCIL GRAPHITE ELECTRODE; CARBON-PASTE ELECTRODE; ORGANIC-ACIDS; ELECTROCATALYTIC OXIDATION; OVEROXIDIZED POLYPYRROLE; CONDUCTING POLYMERS; COATED ELECTRODES; POLYANILINE; ANIONS; SENSOR;
D O I
10.1016/j.bios.2009.05.005
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A potentiometric detector, based on electrodeposition of polypyrrole onto Pt electrode, was investigated in this study. The chromatographic performance of the PPy detector was investigated in ion chromatography. The resulting PPy detector exhibited good performance for AA determination with a wide linear range (1.0 x 10(-6) to 1.0 x 10(-2) M), a highly reproducible response (R.S.D. of 2.45%), without any interference and long-term stability. The calculated detection limit was 7.0 x 10(-5) mM at 3 sigma. The calibration results showed good Nernstian behavior and also satisfactory low detection limit. In order to verify the reliability of the PPy detector, it was applied to the determination of AA in pharmaceutical samples. The results were satisfactory and agreed closely with the manufacturers' stated contents. The PPy electrode can be used as an alternative novel potentiometric detector material for determination of AA in standards and pharmaceutical samples. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3492 / 3497
页数:6
相关论文
共 46 条
[1]   Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode [J].
Ahin, Yuecel ;
Ercan, Betuel ;
Sahin, Mutlu .
JOURNAL OF APPLIED POLYMER SCIENCE, 2008, 108 (05) :3298-3304
[2]   Ion chromatographic determination of some organic acids, chloride and phosphate in coffee and tea [J].
Alcázar, A ;
Fernández-Cáceres, PL ;
Martín, MJ ;
Pablos, F ;
González, AG .
TALANTA, 2003, 61 (02) :95-101
[3]   Iron(II) phthalocyanine-modified carbon-paste electrode for potentiometric detection of ascorbic acid [J].
Amini, MK ;
Shahrokhian, S ;
Tangestaninejad, S ;
Mirkhani, V .
ANALYTICAL BIOCHEMISTRY, 2001, 290 (02) :277-282
[4]   Potentiometric sensors for trace-level analysis [J].
Bakker, E ;
Pretsch, E .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2005, 24 (03) :199-207
[5]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[6]   Electrocatalysis of ascorbic acid ion the glassy carbon electrode chemically modified with polyaniline films [J].
Casella, IG ;
Guascito, MR .
ELECTROANALYSIS, 1997, 9 (18) :1381-1386
[7]   Determination of electroactive organic acids by anion-exchange chromatography using a copper modified electrode [J].
Casella, IG ;
Gatta, M .
JOURNAL OF CHROMATOGRAPHY A, 2001, 912 (02) :223-233
[8]   Optimization of the determination of organic acids and sugars in fruit juices by ion-exclusion liquid chromatography [J].
Chinnici, F ;
Spinabelli, U ;
Riponi, C ;
Amati, A .
JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2005, 18 (2-3) :121-130
[9]   Electrochemical properties of an osmium(II) copolymer film and its electrocatalytic ability towards the oxidation of ascorbic acid in acidic and neutral pH [J].
Foster, Kevin ;
McCormac, Timothy .
ELECTROANALYSIS, 2006, 18 (11) :1097-1104
[10]  
Fritz J.S., 2000, ION CHROMATOGRAPHY, V3rd