Magnetic track array for efficient bead capture in microchannels

被引:13
作者
Abonnenc, Melanie [1 ]
Gassner, Anne-Laure [1 ]
Morandini, Jacques [2 ]
Josserand, Jacques [1 ]
Girault, Hubert H. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, SB, ISIC, LEPA,Stn 6, CH-1015 Lausanne, Switzerland
[2] Astek Rhone Alpes, F-38130 Echirolles, France
关键词
Microfluidics; Magnetism; Permanent magnet; Magnetic bead; Ink; Magnetic track array; Photo-ablation; Polymer; Numerical simulation; LINKED-IMMUNOSORBENT-ASSAY; ON-CHIP; CAPILLARY-ELECTROPHORESIS; PROTEIN ADSORPTION; MICROFLUIDIC CHIP; FLOW; MANIPULATION; SYSTEMS; IMMUNOASSAY; SEPARATION;
D O I
10.1007/s00216-009-3006-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Magnetism-based microsystems, as those dedicated to immunoaffinity separations or (bio) chemical reactions, take benefit of the large surface area-to-volume ratio provided by the immobilized magnetic beads, thus increasing the sensitivity of the analysis. As the sensitivity is directly linked to the efficiency of the magnetic bead capture, this paper presents a simple method to enhance the capture in a microchannel. Considering a microchannel surrounded by two rectangular permanent magnets of different length (L-m=2, 5, 10 mm) placed in attraction, it is shown that the amount of trapped beads is limited by the magnetic forces mainly located at the magnet edges. To overcome this limitation, a polyethylene terephthalate (PET) microchip with an integrated magnetic track array has been prototyped by laser photo-ablation. The magnetic force is therefore distributed all along the magnet length. It results in a multi-plug bead capture, observed by microscope imaging, with a magnetic force value locally enhanced. The relative amount of beads, and so the specific binding surface for further immunoassays, presents a significant increase of 300% for the largest magnets. The influence of the track geometry and relative permeability on the magnetic force was studied by numerical simulations, for the microchip operating with 2-mm-long magnets.
引用
收藏
页码:747 / 757
页数:11
相关论文
共 49 条
[1]   Electrospray micromixer chip for on-line derivatization and kinetic studies [J].
Abonnenc, Melanie ;
Dayon, Lorc ;
Perruche, Brice ;
Lion, Niels ;
Girault, Hubert H. .
ANALYTICAL CHEMISTRY, 2008, 80 (09) :3372-3378
[2]   CHEMICAL-PROCESSING WITH LASERS - RECENT DEVELOPMENTS [J].
BAUERLE, D .
APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1988, 46 (03) :261-270
[3]   Pulsed laser ablation of polyimide: Fundamental aspects [J].
Bauerle, D ;
Himmelbauer, M ;
Arenholz, E .
JOURNAL OF PHOTOCHEMISTRY AND PHOTOBIOLOGY A-CHEMISTRY, 1997, 106 (1-3) :27-30
[4]   Micromixing with linked chains of paramagnetic particles [J].
Biswal, SL ;
Gast, AP .
ANALYTICAL CHEMISTRY, 2004, 76 (21) :6448-6455
[5]   Simultaneous bioassays in a microfluidic channel on plugs of different magnetic particles [J].
Bronzeau, Sandrine ;
Pamme, Nicole .
ANALYTICA CHIMICA ACTA, 2008, 609 (01) :105-112
[6]   Capillary electrophoresis immunoassay using magnetic beads [J].
Chen, Hong-Xu ;
Busnel, Jean-Marc ;
Gassner, Anne-Laure ;
Peltre, Gabriel ;
Zhang, Xin-Xiang ;
Girault, Hubert H. .
ELECTROPHORESIS, 2008, 29 (16) :3414-3421
[7]   Magnetic Beads Based Immunoaffinity Capillary Electrophoresis of Total Serum IgE with Laser-Induced Fluorescence Detection [J].
Chen, Hong-Xu ;
Busnel, Jean-Marc ;
Peltre, Gabriel ;
Zhang, Xin-Xiang ;
Girault, Hubert H. .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9583-9588
[8]   Multitrack electrospray chips [J].
Dayon, Loic ;
Abonnenc, Melanie ;
Prudent, Michel ;
Lion, Niels ;
Girault, Hubert H. .
JOURNAL OF MASS SPECTROMETRY, 2006, 41 (11) :1484-1490
[9]   Manipulation of magnetic microbeads in suspension using micromagnetic systems fabricated with soft lithography [J].
Deng, T ;
Whitesides, GM ;
Radhakrishnan, M ;
Zabow, G ;
Prentiss, M .
APPLIED PHYSICS LETTERS, 2001, 78 (12) :1775-1777
[10]   Magnetophoretic separation of blood cells at the microscale [J].
Furlani, E. P. .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2007, 40 (05) :1313-1319