A two-step scheme for distortion rectification of magnetic resonance images

被引:84
作者
Baldwin, Lesley N. [1 ,2 ]
Wachowicz, Keith [3 ]
Fallone, B. Gino [3 ]
机构
[1] Univ Alberta, Dept Oncol, Edmonton, AB T6G 1Z2, Canada
[2] Univ Alberta, Dept Phys, Div Med Phys, Edmonton, AB T6G 1Z2, Canada
[3] Univ Alberta, Cross Canc Inst, Div Med Phys, Dept Oncol, Edmonton, AB T6G 1Z2, Canada
基金
加拿大创新基金会;
关键词
MRI; distortion; gradient nonlinearity; B-0 in homogeneity; susceptibility; chemical shift; treatment planning; phantom; phase difference mapping; reverse gradient technique; GEOMETRIC DISTORTION; PROSTATE-CANCER; MR-IMAGES; FIELD INHOMOGENEITIES; BRAIN-TUMORS; RADIOTHERAPY; EPI;
D O I
10.1118/1.3180107
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this work is to demonstrate a complete, robust, and time-efficient method for distortion correction of magnetic resonance (MR) images. It is well known that MR images suffer from both machine-related spatial distortions [gradient nonlinearity and main field (B-0) inhomogeneity] and patient-related spatial distortions (susceptibility and chemical shift artifacts), and growing interest in the area of MR-based radiotherapy treatment planning has put new requirements on the geometric accuracy of such images. The authors present a two-step method that combines a phantom-based reverse gradient technique for measurement of gradient nonlinearities and a patient-based phase difference mapping technique for measurement of B-0 inhomogeneities, susceptibility, and chemical shift distortions. The phase difference mapping technique adds only minutes to the total patient scan time and can be used to correct a variety of images of the same patient and anatomy. The technique was tested on several different phantoms, each designed to isolate one type of distortion. The mean distortion was reduced to 0.2 +/- 0.1 mm in both gradient echo and spin echo images of a grid phantom. For the more difficult case of a highly distorted echo planar image, residual distortion was reduced to subvoxel dimensions. As a final step, the technique was implemented on patient images. The current technique is effective, time efficient, and robust and provides promise for preparing distortion-rectified MR images for use in MR-based treatment planning. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3180107]
引用
收藏
页码:3917 / 3926
页数:10
相关论文
共 28 条
  • [1] Characterization, prediction, and correction of geometric distortion in 3 T MR images
    Baldwin, Lesley N.
    Wachowicz, Keith
    Thomas, Steven D.
    Rivest, Ryan
    Fallone, B. Gino
    [J]. MEDICAL PHYSICS, 2007, 34 (02) : 388 - 399
  • [2] Detection and correction of geometric distortion in 3D MR images
    Breeuwer, M
    Holden, M
    Zylka, W
    [J]. MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 1110 - 1120
  • [3] A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES
    CHANG, H
    FITZPATRICK, JM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) : 319 - 329
  • [4] Dosimetric evaluation of MRI-based treatment planning for prostate cancer
    Chen, L
    Price, RA
    Nguyen, TB
    Wang, L
    Li, JS
    Qin, L
    Ding, M
    Palacio, E
    Ma, CM
    Pollack, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (22) : 5157 - 5170
  • [5] Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy:: Creation of digitally reconstructed radiographs
    Chen, Lili
    Nguyen, Thai-Binh
    Jones, Elan
    Chen, Zuoqun
    Luo, Wei
    Wang, Lu
    Price, Robert A., Jr.
    Pollack, Alan
    Ma, C.-M. Charlie
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03): : 903 - 911
  • [6] MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT
    Chen, LL
    Price, RA
    Wang, L
    Li, JS
    Qin, LH
    McNeeley, S
    Ma, CMC
    Freedman, GM
    Pollack, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 636 - 647
  • [7] Chen NK, 1999, MAGNET RESON MED, V41, P1206, DOI 10.1002/(SICI)1522-2594(199906)41:6<1206::AID-MRM17>3.0.CO
  • [8] 2-L
  • [9] New robust 3-D phase unwrapping algorithms: Application to magnetic field mapping and undistorting echoplanar images
    Cusack, R
    Papadakis, N
    [J]. NEUROIMAGE, 2002, 16 (03) : 754 - 764
  • [10] The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer
    Debois, M
    Oyen, R
    Maes, F
    Verswijvel, G
    Gatti, G
    Bosmans, H
    Feron, M
    Bellon, E
    Kutcher, G
    Van Poppel, H
    Vanuytsel, L
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04): : 857 - 865