Solar PV in the airport environment: A review of glare assessment approaches & metrics

被引:10
作者
Sreenath, S. [1 ]
Sudhakar, K. [2 ,3 ,4 ]
Yusop, A. F. [2 ,4 ]
机构
[1] Univ Malaysia Pahang, Renewable Energy & Energy Efficiency Res Cluster, Pahang 26600, Malaysia
[2] Univ Malaysia Pahang, Fac Mech & Automot Engn Technol, Pahang 26600, Malaysia
[3] Maulana Azad Natl Inst Technol Bhopal, Energy Ctr, Bhopal 462003, Madhya Pradesh, India
[4] Univ Malaysia Pahang, Automot Engn Ctr, Pahang 26600, Malaysia
关键词
Airport; Glare; Hazard; Reflectivity; Solar PV;
D O I
10.1016/j.solener.2021.01.023
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Solar photovoltaic technologies are increasingly implemented in airport premises. In certain conditions of sun path, the glare from solar photovoltaic modules may the reduce visibility of pilots and air traffic controllers. Despite the threat to aviation safety with solar installations in airport, only a few countries have framed regulation on glare impact. The paper attempts to study the various factors affecting the occurrence of glare from solar PV array in Airport. The main objective is to review the approaches and metrics for assessing the glare impact from the solar photovoltaic array. In addition, the work summarises the glare guidelines existing in USA, Canada and European nations. The main factors that influence the glare occurrence are suns position, tilt angle, Surface texture, color and location of PV module. It was concluded that the existing glare assessment approaches are of limited practical use in the worldwide scenario. Though there are several limitations with the existing glare indices, the Ho et al metrics is reasonably a good indicator for glare assessment in airport solar PV installations. Guidelines formulated by Federal Aviation Administration, (FAA), USA is good enough to be used as guideline for glare impact assessment in other countries. It is envisaged that this work will assist the research communities for the development of the globally acceptable glare assessment and metrics.
引用
收藏
页码:439 / 451
页数:13
相关论文
共 55 条
  • [31] Performance evaluation of 10 MW grid connected solar photovoltaic power plant in India
    Kumar, B. Shiva
    Sudhakar, K.
    [J]. ENERGY REPORTS, 2015, 1 : 184 - 192
  • [32] Labib R., 2014, ANAL QUANTIFICATION, P652
  • [33] Ministry for Environment Health and Consumer Protection, 2014, LIGHT GUID
  • [34] Protogeropoulos C., 2010, 25 EUR PV SOL EN C, P355, DOI [10.4229/25THEUPVSEC2010-1DV.2.16, DOI 10.4229/25THEUPVSEC2010-1DV.2.16]
  • [35] Anti-reflective coatings: A critical, in-depth review
    Raut, Hemant Kumar
    Ganesh, V. Anand
    Nair, A. Sreekumaran
    Ramakrishna, Seeram
    [J]. ENERGY & ENVIRONMENTAL SCIENCE, 2011, 4 (10) : 3779 - 3804
  • [36] The dark side of photovoltaic-3D simulation of glare assessing risk and discomfort
    Rose, Thomas
    Wollert, Alexander
    [J]. ENVIRONMENTAL IMPACT ASSESSMENT REVIEW, 2015, 52 : 24 - 30
  • [37] Sandia National Laboratories, 2018, SOL GLAR HAZ AN TOOL
  • [38] Service technique of civil aviation F, 2013, VIS DIT LINK SOL PAN
  • [39] Solar PV and BIPV system: Barrier, challenges and policy recommendation in India
    Shukla, Akash Kumar
    Sudhakar, K.
    Baredar, Prashant
    Mamat, Rizalman
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 82 : 3314 - 3322
  • [40] Simulation and performance analysis of 110 kWp grid-connected photovoltaic system for residential building in India: A comparative analysis of various PV technology
    Shukla, Akash Kumar
    Sudhakar, K.
    Baredar, Prashant
    [J]. ENERGY REPORTS, 2016, 2 : 82 - 88