Electromembrane extraction-high-performance liquid chromatography-ultraviolet detection of phenobarbital and phenytoin in human plasma, saliva, and urine

被引:12
|
作者
Dolatabadi, Roshanak [1 ]
Mohammadi, Ali [1 ,2 ]
Nojavan, Saeed [3 ]
Yaripour, Saeid [1 ]
Tafakhori, Abbas [4 ]
Shirangi, Mehrnoosh [1 ]
机构
[1] Univ Tehran Med Sci, Fac Pharm, Dept Drug & Food Control, Tehran, Iran
[2] Univ Tehran Med Sci, Fac Pharm, Nanotechnol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran, Iran
[4] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Neurosci Inst, Iranian Ctr Neurol Res, Tehran, Iran
关键词
3D printing; electromembrane extraction; HPLC‐ UV; phenobarbital and phenytoin; SOLID-PHASE EXTRACTION; HEAVY-METAL CATIONS; CAPILLARY-ELECTROPHORESIS; AMINO-ACIDS; MASS-SPECTROMETRY; GRAPHENE OXIDE; MODEL ANALYTE; HOLLOW-FIBER; MICROEXTRACTION; QUANTIFICATION;
D O I
10.1002/jccs.202100016
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The current article is focused on introduction and validation of electro-membrane extraction along with a high-performance liquid chromatography combined with UV detector for the identification of the antiepileptic drugs phenytoin (PT) and phenobarbital (PB) in plasma, saliva, and urine. In addition, 3D-printing was utilized to fabricate the designed caps required for fixing the electrodes in the prepared setup, giving us a high potential in device fabrication with various dimensions. To arrive at the highest extraction of PB and PT, the parameters impacting the extraction efficiency of electromembrane extraction for example, supported liquid membrane composition, sample solution pH, applied voltage, extraction time along with effect of graphene oxide are examined in detail. In optimized experimental conditions, the calibration plots were obtained to be linear on the concentration range of 25-500 ng/L with the detection limit and quantitation limit of 7.5 and 25 ng/L for both of PB and PT. Relative standard deviations of <9.9% and <9.1% were found for PB and PT, respectively and the enrichment factor for the presented method was computed to be 25.4 and 44.7 for PB and PT, respectively. The proposed method was satisfactorily employed in determination of PB and PT in plasma, urine and saliva.
引用
收藏
页码:1522 / 1530
页数:9
相关论文
共 50 条
  • [31] Electro membrane extraction of sodium diclofenac as an acidic compound from wastewater, urine, bovine milk, and plasma samples and quantification by high-performance liquid chromatography
    Davarani, Saied Saeed Hosseiny
    Pourahadi, Ahmad
    Nojavan, Saeed
    Banitaba, Mohammad Hossein
    Nasiri-Aghdam, Mahnaz
    ANALYTICA CHIMICA ACTA, 2012, 722 : 55 - 62
  • [32] Improved method for analyzing the degradation of estrogens in water by solid-phase extraction coupled with ultra performance liquid chromatography-ultraviolet detection
    Zheng, Minggang
    Wang, Ling
    Bi, Yuandui
    Liu, Feng
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2011, 23 (04) : 693 - 698
  • [33] Screening, recognition and quantitation of salbutamol residues in ham sausages by molecularly imprinted solid phase extraction coupled with high-performance liquid chromatography-ultraviolet detection
    Yan, Hongyuan
    Wang, Ruiling
    Han, Yehong
    Liu, Suting
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 900 : 18 - 23
  • [34] Simultaneous determination of aliskiren, amlodipine and hydrochlorothiazide in spiked human plasma and urine by high performance liquid chromatography
    Aydogmus, Zeynep
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (04) : 502 - 509
  • [35] pH-resistant titania hybrid organic-inorganic coating for stir bar sorptive extraction of drugs of abuse in urine samples followed by high performance liquid chromatography-ultraviolet visible detection
    Lan, Lidan
    Hu, Bin
    Yu, Chunhe
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (45) : 7003 - 7009
  • [36] DETERMINATION OF FAMOTIDINE IN HUMAN PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CVITKOVIC, L
    ZUPANCICKRALJ, L
    MARSEL, J
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (02) : 207 - 210
  • [37] Simple high-performance liquid chromatography-ultraviolet method for simultaneous separation and detection of 14 bisphenol pollutants in building materials
    Han, Xiaoxuan
    Zhao, Ruijie
    Tian, Yong
    Li, Yutong
    Chen, Xu-Wei
    Ma, Jiping
    Wang, Weiliang
    Zhang, Yanfeng
    Geng, Song
    Liu, Menglin
    JOURNAL OF SEPARATION SCIENCE, 2023, 46 (11)
  • [38] Determination of Phthalates Released from Paper Packaging Materials by Solid-Phase Extraction-High-Performance Liquid Chromatography
    Gao, Xin
    Yang, Bofeng
    Tang, Zhixu
    Luo, Xin
    Wang, Fengmei
    Xu, Hui
    Cai, Xue
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2014, 52 (05) : 383 - 389
  • [39] Determination of metoprolol and its two metabolites in human plasma and urine by high performance liquid chromatography with fluorescence detection and its application in pharmacokinetics
    Xu, Tao
    Bao, Shihui
    Geng, Peiwu
    Luo, Jun
    Yu, Lei
    Pan, Peipei
    Chen, Yi
    Hu, Guoxin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 937 : 60 - 66
  • [40] Solid-phase extraction with liquid chromatography and ultraviolet detection for the assay of antidepressant drugs in human plasma
    Bakkali, A
    Corta, E
    Ciria, JI
    Berrueta, LA
    Gallo, B
    Vicente, F
    TALANTA, 1999, 49 (04) : 773 - 783