Electromembrane extraction-high-performance liquid chromatography-ultraviolet detection of phenobarbital and phenytoin in human plasma, saliva, and urine

被引:12
|
作者
Dolatabadi, Roshanak [1 ]
Mohammadi, Ali [1 ,2 ]
Nojavan, Saeed [3 ]
Yaripour, Saeid [1 ]
Tafakhori, Abbas [4 ]
Shirangi, Mehrnoosh [1 ]
机构
[1] Univ Tehran Med Sci, Fac Pharm, Dept Drug & Food Control, Tehran, Iran
[2] Univ Tehran Med Sci, Fac Pharm, Nanotechnol Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ, Dept Analyt Chem & Pollutants, Tehran, Iran
[4] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Neurosci Inst, Iranian Ctr Neurol Res, Tehran, Iran
关键词
3D printing; electromembrane extraction; HPLC‐ UV; phenobarbital and phenytoin; SOLID-PHASE EXTRACTION; HEAVY-METAL CATIONS; CAPILLARY-ELECTROPHORESIS; AMINO-ACIDS; MASS-SPECTROMETRY; GRAPHENE OXIDE; MODEL ANALYTE; HOLLOW-FIBER; MICROEXTRACTION; QUANTIFICATION;
D O I
10.1002/jccs.202100016
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The current article is focused on introduction and validation of electro-membrane extraction along with a high-performance liquid chromatography combined with UV detector for the identification of the antiepileptic drugs phenytoin (PT) and phenobarbital (PB) in plasma, saliva, and urine. In addition, 3D-printing was utilized to fabricate the designed caps required for fixing the electrodes in the prepared setup, giving us a high potential in device fabrication with various dimensions. To arrive at the highest extraction of PB and PT, the parameters impacting the extraction efficiency of electromembrane extraction for example, supported liquid membrane composition, sample solution pH, applied voltage, extraction time along with effect of graphene oxide are examined in detail. In optimized experimental conditions, the calibration plots were obtained to be linear on the concentration range of 25-500 ng/L with the detection limit and quantitation limit of 7.5 and 25 ng/L for both of PB and PT. Relative standard deviations of <9.9% and <9.1% were found for PB and PT, respectively and the enrichment factor for the presented method was computed to be 25.4 and 44.7 for PB and PT, respectively. The proposed method was satisfactorily employed in determination of PB and PT in plasma, urine and saliva.
引用
收藏
页码:1522 / 1530
页数:9
相关论文
共 50 条
  • [1] A study on determination of theophylline in plasma and urine sample using electromembrane extraction combined with high-performance liquid chromatography-ultraviolet
    Dolatabadi, Roshanak
    Zaheri, Mohammadreza
    Ebrahimi, Shahriar
    Mohammadi, Ali
    CHEMICAL PAPERS, 2022, 76 (02) : 681 - 690
  • [2] Sensitive determination of ethosuximide in human fluids by electromembrane extraction coupled with high performance liquid chromatography ultraviolet spectroscopy
    Nabizadeh, Hassan
    Mohammadi, Ali
    Dolatabadi, Roshanak
    Nojavan, Saeed
    Vahabizad, Fahimeh
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2023, 70 (01) : 76 - 86
  • [3] A study on determination of theophylline in plasma and urine sample using electromembrane extraction combined with high-performance liquid chromatography–ultraviolet
    Roshanak Dolatabadi
    Mohammadreza Zaheri
    Shahriar Ebrahimi
    Ali Mohammadi
    Chemical Papers, 2022, 76 : 681 - 690
  • [4] Determination of metoprolol in human plasma and urine by high-performance liquid chromatography with fluorescence detection
    Yilmaz, Bilal
    Asci, Ali
    Arslan, Sakir
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (13) : 1904 - 1908
  • [5] Determination of chloramphenicol and three tetracyclines by solid phase extraction and high performance liquid chromatography-ultraviolet detection
    Liu Hong
    Zhang Guo-Ping
    Liu Cong-Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (03) : 315 - 319
  • [6] Dispersive liquid-liquid microextraction followed by high-performance liquid chromatography-ultraviolet detection to determination of opium alkaloids in human plasma
    Ahmadi-Jouibari, Toraj
    Fattahi, Nazir
    Shamsipur, Mojtaba
    Pirsaheb, Meghdad
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 85 : 14 - 20
  • [7] A ferrofluidic hydrophobic deep eutectic solvent for the extraction of doxycycline from urine, blood plasma and milk samples prior to its determination by high-performance liquid chromatography-ultraviolet
    Dil, Ebrahim Alipanahpour
    Ghaedi, Mehrorang
    Asfaram, Arash
    Tayebi, Lobat
    Mehrabi, Fatemeh
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1613
  • [8] Quantitation of atorvastatin in human plasma using directly suspended acceptor droplet in liquid-liquid-liquid microextraction and high-performance liquid chromatography-ultraviolet detection
    Farahani, Hadi
    Norouzi, Parviz
    Beheshti, Abolghasem
    Sobhi, Hamid Reza
    Dinarvand, Rasoul
    Ganjali, Mohammad Reza
    TALANTA, 2009, 80 (02) : 1001 - 1006
  • [9] Exhaustive electromembrane extraction of some basic drugs from human plasma followed by liquid chromatography-mass spectrometry
    Eibak, Lars Erik Eng
    Gjelstad, Astrid
    Rasmussen, Knut Einar
    Pedersen-Bjergaard, Stig
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 57 : 33 - 38
  • [10] Electromembrane extraction followed by high performance liquid chromatography: an efficient method for extraction and determination of morphine, oxymorphone, and methylmorphine from urine samples
    Yamini, Yadollah
    Pourali, Au
    Seidi, Shahram
    Rezazadeh, Maryam
    ANALYTICAL METHODS, 2014, 6 (15) : 5554 - 5565