Dynamic accuracy measurement system for mechanical wristwatch

被引:4
作者
Aihara, Tatsuhito [1 ]
Kamio, Chihiro [2 ]
Hara, Yosuke [3 ]
Ito, Kengo [4 ]
Jujo, Koichiro [4 ]
机构
[1] Hosei Univ, Fac Sci & Engn, Dept Mech Engn, 3-7-2 Kajinocho, Koganei, Tokyo, Japan
[2] Hosei Univ, Grad Sch Sci & Engn, Dept Mech Engn, 3-7-2 Kajinocho, Koganei, Tokyo, Japan
[3] Seiko Holdings Corp, Prod Engn Dept, 563 Takatsukashinden, Matsudo, Chiba 2702222, Japan
[4] Seiko Watch Corp, Planning & Dev Div, Mihama Ku, 8,Nakase 1 Chome, Chiba, Chiba 2618507, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2021年 / 70卷
关键词
Rate; Mechanical wristwatch; Measurement; Dynamic accuracy; Photo interrupter;
D O I
10.1016/j.precisioneng.2021.01.018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The time shift of mechanical watches is caused by individual differences (manufacturing error), environmental temperature, magnetism, posture, impact force and dynamic environment. The easiest and clearest method of measuring the accuracy of mechanical watches is to measure the time shift by comparing it with the reference time. The disadvantage of this method is that it can only measure accuracy at a certain time. Another method for measuring the accuracy of mechanical watches uses a watch timing machine that obtains the vibration sound of a watch using a microphone and calculates accuracy in the short term. This method can measure the change in watch accuracy over time. However, it cannot be used to measure accuracy in a dynamic environment because the watch timing machine is large and there is a sound noise. To clarify the accuracy of mechanical watches in dynamic environment, this study developed an accuracy measurement system which can be carried and measure in a dynamic environment. This study monitors the movement of a partly constituted mechanical watch using a photo interrupter and develops a method to calculate the rate and amplitude of a balance wheel from the output value of the photo interrupter. The validity of the developed system is verified by comparing the time shift of the system and radio clock time over the long term. The developed system, can be used in a dynamic environment because it consists of the photo interrupter in the watch case. Moreover, this study conducted measurements under forced vibration using vibration generator and during walking with the system.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [41] Measurement accuracy and uncertainty in plant biomechanics
    Nelson, Nathanael
    Stubbs, Christopher J.
    Larson, Ryan
    Cook, Douglas D.
    [J]. JOURNAL OF EXPERIMENTAL BOTANY, 2019, 70 (14) : 3649 - 3658
  • [42] In- Plane Micro-Vibration Measurement System Based on Dynamic Holography
    Shen Xu
    Gao Jiongye
    Xue Yong
    Zhang Bin
    Feng Qibo
    [J]. ACTA OPTICA SINICA, 2023, 43 (05)
  • [43] Automated Broadband High-Dynamic-Range Nonlinear Distortion Measurement System
    Wilkerson, Jonathan R.
    Gard, Kevin G.
    Steer, Michael B.
    [J]. IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2010, 58 (05) : 1273 - 1282
  • [44] Simplified Calibration Method for Radiation Temperature Measurement System with Wide Dynamic Range
    Ma Dongxiao
    Wang Jiachun
    Chen Zongsheng
    Wang Bing
    Liu Yang
    [J]. ACTA OPTICA SINICA, 2019, 39 (06)
  • [45] Error Analysis and Accuracy Assurance of Two-Dimensional Rotatory Axes for Laser Tracing Measurement System
    Song Huixu
    Shi Zhaoyao
    Chen Hongfang
    Sun Yanqiang
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2018, 45 (05):
  • [46] Opto-Mechanical System Design of Rotating Virtual Objective for Autocollimate Dynamic Target
    Yang Yifeng
    Zhao Yang
    [J]. LASER & OPTOELECTRONICS PROGRESS, 2021, 58 (23)
  • [47] The design and development of a measurement system for the investigation of dynamic micromotion in total knee joint replacements
    DiSilvestro, MR
    Swope, SW
    Dietz, TL
    McNulty, DE
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (03) : 1126 - 1132
  • [48] Simultaneous Measurement System of Thickness and Temperature of Two-Wavelength Dynamic Liquid Film
    Yang H.
    Deng H.
    Jiang Y.
    Zhang Y.
    Su M.
    [J]. Zhongguo Jiguang/Chinese Journal of Lasers, 2019, 46 (04):
  • [49] Simultaneous Measurement System of Thickness and Temperature of Two-Wavelength Dynamic Liquid Film
    Yang Huinan
    Deng Hao
    Jiang Yong
    Zhang Yuexing
    Su Mingxu
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2019, 46 (04):
  • [50] Analysis of accuracy of measurement by Doppler laser meters
    Skeivalas, J
    Giniotis, V
    [J]. OPTICAL ENGINEERING, 2003, 42 (07) : 2025 - 2028