Dynamic accuracy measurement system for mechanical wristwatch

被引:4
作者
Aihara, Tatsuhito [1 ]
Kamio, Chihiro [2 ]
Hara, Yosuke [3 ]
Ito, Kengo [4 ]
Jujo, Koichiro [4 ]
机构
[1] Hosei Univ, Fac Sci & Engn, Dept Mech Engn, 3-7-2 Kajinocho, Koganei, Tokyo, Japan
[2] Hosei Univ, Grad Sch Sci & Engn, Dept Mech Engn, 3-7-2 Kajinocho, Koganei, Tokyo, Japan
[3] Seiko Holdings Corp, Prod Engn Dept, 563 Takatsukashinden, Matsudo, Chiba 2702222, Japan
[4] Seiko Watch Corp, Planning & Dev Div, Mihama Ku, 8,Nakase 1 Chome, Chiba, Chiba 2618507, Japan
来源
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY | 2021年 / 70卷
关键词
Rate; Mechanical wristwatch; Measurement; Dynamic accuracy; Photo interrupter;
D O I
10.1016/j.precisioneng.2021.01.018
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The time shift of mechanical watches is caused by individual differences (manufacturing error), environmental temperature, magnetism, posture, impact force and dynamic environment. The easiest and clearest method of measuring the accuracy of mechanical watches is to measure the time shift by comparing it with the reference time. The disadvantage of this method is that it can only measure accuracy at a certain time. Another method for measuring the accuracy of mechanical watches uses a watch timing machine that obtains the vibration sound of a watch using a microphone and calculates accuracy in the short term. This method can measure the change in watch accuracy over time. However, it cannot be used to measure accuracy in a dynamic environment because the watch timing machine is large and there is a sound noise. To clarify the accuracy of mechanical watches in dynamic environment, this study developed an accuracy measurement system which can be carried and measure in a dynamic environment. This study monitors the movement of a partly constituted mechanical watch using a photo interrupter and develops a method to calculate the rate and amplitude of a balance wheel from the output value of the photo interrupter. The validity of the developed system is verified by comparing the time shift of the system and radio clock time over the long term. The developed system, can be used in a dynamic environment because it consists of the photo interrupter in the watch case. Moreover, this study conducted measurements under forced vibration using vibration generator and during walking with the system.
引用
收藏
页码:117 / 123
页数:7
相关论文
共 50 条
  • [21] Evaluation of dynamic accuracy and latency of a surface-guided radiotherapy system
    Yamauchi, Ryohei
    Tomita, Fumihiro
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2025, 18 (01) : 136 - 146
  • [22] Methods of Increasing of Onboard Tracking System with Optical Device Dynamic Accuracy
    Sheval, Valery
    Rozhnin, Nikolay
    VIII INTERNATIONAL SCIENTIFIC SIBERIAN TRANSPORT FORUM, VOL 1, 2020, 1115 : 540 - 549
  • [23] Knowledge based system for technical diagnostic in mechanical vibration measurement
    Jecmenica, N
    Petkovic, D
    PREVIOUS EXPERIENCE AND CURRENT INNOVATIONS IN NON-DESTRUCTIVE TESTING, 2001, : 422 - 422
  • [24] The measurement of mechanical parameters of a switched reluctance motor drive system
    Gobbi, R.
    Sahoo, N. C.
    Vejian, R.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2007, 18 (11) : 3636 - 3644
  • [25] Development of Mechanical Actuator for Deep-Hole Measurement System
    Ali, Md Hazrat
    Katsuki, Akio
    Sajima, Takao
    Murakami, Hiroshi
    Kurokawa, Syuhei
    TRENDS IN INTELLIGENT ROBOTICS, AUTOMATION, AND MANUFACTURING, 2012, 330 : 280 - +
  • [26] VERIFICATION OF TORSIONAL OSCILLATING MECHANICAL SYSTEM DYNAMIC CALCULATION RESULTS
    Kassay, Peter
    Homisin, Jaroslav
    Copan, Pavol
    Urbansky, Matej
    SCIENTIFIC JOURNAL OF SILESIAN UNIVERSITY OF TECHNOLOGY-SERIES TRANSPORT, 2014, 84 : 29 - 34
  • [27] Design of Large-size Aspheric Measurement System and Motion Accuracy Analysis
    Zhu Yonglu
    Guo Yinbiao
    Luo Wei
    Chen Lushuang
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656
  • [28] Vision system calibration and sub-pixel measurement of mechanical parts
    Lanzetta, M
    Tantussi, G
    AMST'99: ADVANCED MANUFACTURING SYSTEMS AND TECHNOLOGY, 1999, (406): : 695 - 702
  • [29] Analysis on a method of convenient dynamic accuracy appraisal for optical theodolite
    Gong, Zhihua, 1600, Chinese Optical Society (34):
  • [30] Monte Carlo Analysis of Measurement Uncertainties for On-Wafer Multiline TRL Calibration Including Dynamic Accuracy
    Luan, Peng
    Wang, Yibang
    Zhao, Wei
    Liu, Chen
    Liang, Faguo
    Wu, Aihua
    Du, Jing
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2020, 69 (11) : 8874 - 8880