A prospective randomized trial comparing the safety and efficacy of three commercially available closure devices (Angioseal, Vasoseal and Duett)

被引:59
作者
Michalis, LK
Rees, MR
Patsouras, D
Katsouras, CS
Goudevenos, J
Pappas, S
Sourla, E
Kolettis, T
Sioros, L
Zotou, P
Gartzou-Matsouka, P
Sideris, DA
机构
[1] Univ Hosp Ioannina, Dept Cardiac, Ioannina, Greece
[2] Univ Bristol, Dept Radiol, Bristol BS8 1TH, Avon, England
关键词
coronary angiography; coronary angioplasty; puncture closure device;
D O I
10.1007/s00270-002-1942-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: We compared the safety and efficacy of three closure devices (Angioseal, Vasoseal and Duett) used to close arterial puncture sites in patients who underwent coronary percutaneous procedures. Methods: A prospective randomized, single-center trial was carried out of consecutive patients who underwent coronary angiography [705 patients: Angioseal (243),Vasoseal (228) and Duett (234)] or angioplasty [146 patients: Angioseal (47), Vasoseal (52) and Duett (47)]. Results: In the angiography patients the device deployment rates were similar, with the Angioseal been significantly slower in achieving hemostasis (p = 0.0001) but resulting in earlier ambulation (p = 0.0001). In the coronary angioplasty patients the deployment rates were similar to those for angiography: time to hemostasis was longer for the Angioseal (p = 0.003), while ambulation times were not different, although prolonged compared with angiography (p = 0.0001). The three devices had similar major complication rates. The Vasoseal had a higher major complication rate after angioplasty than after angiography (p = 0.004). The incidence rate of peripheral embolization was lower when the Angioseal was utilized. Severe complications were mainly seen in patients who received abciximab. Conclusions: The three closure devices had high rates of successful deployment and were relatively safe. The Angioseal resulted in earlier ambulation after angiography. Utilization of closure devices after abciximab administration possibly increased the complications.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 24 条
[1]  
Carere RG, 1998, CATHETER CARDIO DIAG, V43, P124, DOI 10.1002/(SICI)1097-0304(199802)43:2<124::AID-CCD2>3.0.CO
[2]  
2-C
[3]  
Chamberlin JR, 1999, CATHETER CARDIO INTE, V47, P143, DOI 10.1002/(SICI)1522-726X(199906)47:2<143::AID-CCD1>3.0.CO
[4]  
2-M
[5]  
Cooper CL, 1999, CATHETER CARDIO INTE, V48, P301, DOI 10.1002/(SICI)1522-726X(199911)48:3<301::AID-CCD15>3.0.CO
[6]  
2-F
[7]   Surgical complications from hemostatic puncture closure devices [J].
Eidt, JF ;
Habibipour, S ;
Saucedo, JF ;
McKee, J ;
Southern, F ;
Barone, GW ;
Talley, JD ;
Moursi, M .
AMERICAN JOURNAL OF SURGERY, 1999, 178 (06) :511-515
[8]   IMMEDIATE SEALING OF ARTERIAL PUNCTURE SITES AFTER CARDIAC-CATHETERIZATION AND CORONARY ANGIOPLASTY USING A BIODEGRADABLE COLLAGEN PLUG - RESULTS OF AN INTERNATIONAL REGISTRY [J].
ERNST, SMPG ;
TJONJOEGIN, RM ;
SCHRADER, R ;
KALTENBACH, M ;
SIGWART, U ;
SANBORN, TA ;
PLOKKER, HWT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (04) :851-855
[9]  
FORAN JPM, 1993, BRIT HEART J, V69, P424
[10]  
Goyen M, 2000, CATHETER CARDIO INTE, V49, P142, DOI 10.1002/(SICI)1522-726X(200002)49:2<142::AID-CCD5>3.3.CO