Effect of Left Atrial Ablation Process and Strategy on Microemboli Formation During Irrigated Radiofrequency Catheter Ablation in an In Vivo Model

被引:48
作者
Takami, Mitsuru [1 ]
Lehmann, H. Immo [1 ]
Parker, Kay D. [1 ]
Welker, Kirk M. [2 ]
Johnson, Susan B. [1 ]
Packer, Douglas L. [1 ]
机构
[1] Mayo Clin, Translat Intervent Electrophysiol Lab, Rochester, MN 55902 USA
[2] Mayo Clin, Dept Radiol, Rochester, MN 55902 USA
关键词
catheter ablation; embolism; magnetic resonance imaging; microbubbles; pulmonary veins; PULMONARY VEIN ISOLATION; FIBRILLATION; THROMBUS; SIGNALS; FLOW; AIR;
D O I
10.1161/CIRCEP.115.003226
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Formation of microemboli during catheter ablation has been suggested as a cause for asymptomatic cerebral emboli. However, it is unknown which part of the process and ablation setting/strategy is most strongly related to this occurrence. Methods and Results A total of 27 pigs were used. Catheter/sheath manipulations in left atrium were performed in 25 of 27 pigs outfitted with microemboli monitoring systems. Ablations using open-irrigated radiofrequency catheters were performed in 18 of 25 pigs. Two of 27 pigs did not undergo left atrial procedures and were injected with microembolic materials in the carotid artery to serve as positive controls. In total, 334 sheath/catheter manipulations (transseptal puncture, sheath flushing, catheter insertion, pulmonary vein venography, and sheath exchange) and 333 radiofrequency applications (power setting, 30/50 W; point-by-point/drag ablations) were analyzed. High microbubble volume in the extracorporeal circulation loop and a high number of microembolic signals in carotid artery were observed during sheath/catheter manipulations especially in saline/contrast injections at fast speed and ablations with steam pop. Fast sheath flushing produced significantly higher microbubble volume than slow sheath flushing (median, 12 200 versus 121 nL; P<0.0001). A total of 44 of 126 (35%) blood filters in the circulation loop showed microparticles (thrombus/coagulum and tissue). Most of them were seen after radiofrequency application especially in 50-W ablations, drag ablations, and steam pop. Brain magnetic resonance imaging showed positive-embolic lesions in control pigs. Conclusions Formation of microbubbles was the greatest during fast saline/contrast injections and steam pops, whereas high-power radiofrequency applications, drag ablations, and steam pops produced most of the microparticles.
引用
收藏
页数:11
相关论文
共 22 条
[1]  
Bruce CJ, 2003, CIRCULATION, V108, P321
[2]   Discrepancies between catheter tip and tissue temperature in cooled-tip ablation - Relevance to guiding left atrial ablation [J].
Bruce, GK ;
Bunch, TJ ;
Milton, MA ;
Sarabanda, A ;
Johnson, SB ;
Packer, DL .
CIRCULATION, 2005, 112 (07) :954-960
[3]   Does periprocedural anticoagulation management of atrial fibrillation affect the prevalence of silent thromboembolic lesion detected by diffusion cerebral magnetic resonance imaging in patients undergoing radiofrequency atrial fibrillation ablation with open irrigated catheters? Results from a prospective multicenter study [J].
Di Biase, Luigi ;
Gaita, Fiorenzo ;
Toso, Elisabetta ;
Santangeli, Pasquale ;
Mohanty, Prasant ;
Rutledge, Neal ;
Yan, Xue ;
Mohanty, Sanghamitra ;
Trivedi, Chintan ;
Bai, Rong ;
Price, Justin ;
Horton, Rodney ;
Gallinghouse, G. Joseph ;
Beheiry, Salwa ;
Zagrodzky, Jason ;
Canby, Robert ;
Leclercq, Jean Francois ;
Halimi, Franck ;
Scaglione, Marco ;
Cesarani, Federico ;
Faletti, Riccardo ;
Sanchez, Javier ;
Burkhardt, J. David ;
Natale, Andrea .
HEART RHYTHM, 2014, 11 (05) :791-798
[4]   Radiofrequency Catheter Ablation of Atrial Fibrillation: A Cause of Silent Thromboembolism? Magnetic Resonance Imaging Assessment of Cerebral Thromboembolism in Patients Undergoing Ablation of Atrial Fibrillation [J].
Gaita, Fiorenzo ;
Caponi, Domenico ;
Pianelli, Martina ;
Scaglione, Marco ;
Toso, Elisabetta ;
Cesarani, Federico ;
Boffano, Carlo ;
Gandini, Giovanni ;
Valentini, Maria Consuelo ;
De Ponti, Roberto ;
Halimi, Franck ;
Leclercq, Jean Francois .
CIRCULATION, 2010, 122 (17) :1667-1673
[5]   Complications of Catheter Ablation of Atrial Fibrillation A Systematic Review [J].
Gupta, Aakriti ;
Perera, Tharani ;
Ganesan, Anand ;
Sullivan, Thomas ;
Lau, Dennis H. ;
Roberts-Thomson, Kurt C. ;
Brooks, Anthony G. ;
Sanders, Prashanthan .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (06) :1082-1088
[6]   Microembolism and Catheter Ablation I A Comparison of Irrigated Radiofrequency and Multielectrode-phased Radiofrequency Catheter Ablation of Pulmonary Vein Ostia [J].
Haines, David E. ;
Stewart, Mark T. ;
Ahlberg, Sarah ;
Barka, Noah D. ;
Condie, Cathy ;
Fiedler, Gary R. ;
Kirchhof, Nicole A. ;
Halimi, Franck ;
Deneke, Thomas .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) :16-22
[7]   Microembolism and Catheter Ablation II Effects of Cerebral Microemboli Injection in a Canine Model [J].
Haines, David E. ;
Stewart, Mark T. ;
Barka, Noah D. ;
Kirchhof, Nicole ;
Lentz, Linnea R. ;
Reinking, Nicki M. ;
Urban, Jon F. ;
Halimi, Franck ;
Deneke, Thomas ;
Kanal, Emanuel .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (01) :23-30
[8]   INCREASING DOSES OF INTRACAROTID AIR AND CEREBRAL BLOOD-FLOW IN RABBITS [J].
HELPS, SC ;
MEYERWITTING, M ;
REILLY, PL ;
GORMAN, DF .
STROKE, 1990, 21 (09) :1340-1345
[9]  
Jenderka KV, 1998, ULTRASON S P, V2, P1819
[10]   Transcranial Doppler detection of microembolic signals during pulmonary vein antrum isolation: Implications for titration of radiofrequency energy [J].
Kilicaslan, F ;
Verma, A ;
Saad, E ;
Rossillo, A ;
Davis, DA ;
Prasad, SK ;
Wazni, O ;
Marrouche, NF ;
Raber, LN ;
Cummings, JE ;
Beheiry, S ;
Hao, S ;
Burkhardt, JD ;
Saliba, W ;
Schweikert, RA ;
Martin, DO ;
Natale, A .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (05) :495-501