Study of effects of sleeve grouting defects on the seismic performance of precast concrete shear walls

被引:95
作者
Xiao, Shun [1 ]
Wang, Zhuolin [1 ]
Li, Xiangmin [1 ]
Harries, Kent A. [2 ]
Xu, Qingfeng [1 ]
Gao, Rundong [1 ]
机构
[1] Shanghai Res Inst Bldg Sci Co Ltd, Shanghai Key Lab Engn Struct Safety, Shanghai 200032, Peoples R China
[2] Univ Pittsburgh, Dept Civil & Environm Engn, Pittsburgh, PA 15260 USA
关键词
Precast concrete shear wall; Grouted sleeve connector; Grouting defect; Seismic performance; Energy dissipation capacity;
D O I
10.1016/j.engstruct.2020.111833
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Precast concrete wall systems are effective means of resisting seismic forces in many structures. However, their performance is affected by the ability to properly connect elements ? usually with grout sleeves. Grout sleeve connections are known to be susceptible to backflow during grouting resulting in partially grouted or occasionally entirely ungrouted sleeves. In this study an investigation of the impact of sleeve grouting defects on the seismic performance of precast concrete shear walls is presented. Grouting defects of different sizes and at different positions in the walls were intentionally introduced. Reversed cyclic loading tests of precast concrete shear wall specimens and a comparable monolithically cast-in-place concrete shear wall specimen were performed. The defect-free grouted sleeve panels were shown to be equivalent to monolithic cast walls having continuous bars in terms of capacity although, due to the short sleeve embedment, the precast walls are less stiff and therefore demonstrate reduced ductility. Energy dissipation, however is similar and both monolithically cast and precast walls meet the requirements for use as seismic resistant systems. The study showed that grout sleeve defects adversely affect wall behavior ? primarily when the spliced bar is in tension. The impact of defects can be assessed through standard design equations by assuming that the degree of the defect impacts the force the bar can develop. As demonstrated in this study, wall performance becomes an issue of quantifying and predicting defects and their effect, not on the individual bars, but on the wall panel assembly. The panels in this study were dominated by flexural behavior; thus the reduction in panel moment capacity provides a means of differentiating behavior. Panels that maintained at least 92% of their theoretical flexure capacity were mostly indistinguishable from defect-free panels. Noticeable loss of performance was evident at panel capacities of 85% and lower.
引用
收藏
页数:12
相关论文
共 23 条
[1]  
ACI, 2019, ACI 318-19
[2]  
[Anonymous], 2010, GB 50011-2010
[3]  
[Anonymous], 1975, Dynamics of Structures
[4]  
[Anonymous], 2015, Ministry of Construction of the Peoples Republic of China: Technical Specification for Grout Sleeve Splicing of Rebars
[5]  
[Anonymous], 2015, 500102010 GB
[6]  
[Anonymous], 2014, JGJ 1-2014
[7]  
[Anonymous], 2012, JG/T 398-2012
[8]  
[Anonymous], 2015, JGJ/T 101-2015
[9]  
Bentz E.C., 2000, Sectional Analysis of Reinforced Concrete Members
[10]   Effect of Connection Deficiency on Seismic Performance of Precast Concrete Shear Wall-Frame Structures [J].
Cao, Zijian ;
Li, Quanwang .
JOURNAL OF EARTHQUAKE AND TSUNAMI, 2019, 13 (3-4)