Assessment of ocular blood flow in continuous-flow ventricular assist device by laser speckle flowgraphy

被引:1
作者
Shimamura, Junichi [1 ,2 ]
Nishinaka, Tomohiro [1 ]
Mizuno, Toshihide [1 ]
Tsukiya, Tomonori [1 ]
Inatomi, Ayako [1 ]
Kobayashi, Futoshi [1 ]
Katagiri, Nobumasa [1 ]
Takewa, Yoshiaki [1 ]
Nishimura, Takashi [1 ,3 ]
Ono, Minoru [2 ]
Tatsumi, Eisuke [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr Res Inst, Dept Artificial Organs, 6-1 Kishibe Shimmachi, Suita, Osaka 5648565, Japan
[2] Univ Tokyo, Dept Cardiac Surg, Tokyo, Japan
[3] Ehime Univ, Dept Cardiovasc & Thorac Surg, Matsuyama, Ehime, Japan
关键词
Peripheral circulation; Ventricular assist device; Laser speckle flowgraphy; Ocular blood flow; ROTATIONAL SPEED; PULSATILITY;
D O I
10.1007/s10047-021-01265-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although the influence of continuous-flow left ventricular assist device (CF-LVAD) support on peripheral circulation has been widely discussed, its monitoring modalities are limited. The aim of this study was to assess the peripheral circulation using the laser speckle flowgraph (LSFG) which can quantitatively measure the ocular blood flow. We implanted a centrifugal CF-LVAD (EVAHEART(R); Sun Medical Technology Research Corporation, Nagano, Japan) in five adult goats (body weight 44.5 +/- 2.9 kg) under general anesthesia. The waveform of the central retinal artery using the mean blur rate (MBR) for ocular blood velocity and fluctuations as a parameter of pulsatility were obtained before LVAD implantation and after LVAD full-bypass support. The MBR waveform and LSFG fluctuation data were compared with the waveform and pulsatility index of the external carotid artery using an ultrasonic flow meter to evaluate circulatory patterns at different levels. The MBR waveform pattern of the central retinal artery was pulsatile before LVAD implantation and less pulsatile under LVAD full bypass. The fluctuation was 14.7 +/- 1.86 before LVAD implantation and 3.85 +/- 0.61 under LVAD full bypass (p < 0.01), respectively. The fluctuations of LSFG showed a strong correlation with the pulsatility index of the external carotid artery meaning that similar changes in circulatory pattern were observed at two different levels. Measuring the ocular blood flow using LSFG has potential utility for the assessment of the status of the peripheral circulation and its pulsatility during CF-LVAD.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 18 条
  • [11] Usefulness of Laser Speckle Flowgraphy for the Assessment of Ocular Blood Flow in Extracranial-Intracranial Bypass
    Omodaka, Shunsuke
    Endo, Hidenori
    Doi, Hiroshi
    Shimizu, Hiroaki
    Fujimura, Miki
    Aizawa, Naoko
    Nakazawa, Toru
    Tominaga, Teiji
    [J]. JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (10) : E445 - E448
  • [12] Pulse waveform analysis of optic nerve head circulation for predicting carotid atherosclerotic changes
    Rina, Muramatsu
    Shiba, Tomoaki
    Takahashi, Mao
    Hori, Yuichi
    Maeno, Takatoshi
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 253 (12) : 2285 - 2291
  • [13] Journal of Artificial Organs 2017: the year in review
    Sawa, Y.
    Matsumiya, G.
    Matsuda, K.
    Tatsumi, E.
    Abe, T.
    Fukunaga, K.
    Ichiba, S.
    Kishida, A.
    Kokubo, K.
    Masuzawa, T.
    Myoui, A.
    Nishimura, M.
    Nishimura, T.
    Nishinaka, T.
    Okamoto, E.
    Tokunaga, S.
    Tomo, T.
    Tsukiya, T.
    Yagi, Y.
    Yamaoka, T.
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (01) : 1 - 7
  • [14] Journal of Artificial Organs 2016: the year in review
    Sawa, Y.
    Matsumiya, G.
    Matsuda, K.
    Tatsumi, E.
    Abe, T.
    Fukunaga, K.
    Ichiba, S.
    Kishida, A.
    Kokubo, K.
    Masuzawa, T.
    Myoui, A.
    Nishimura, M.
    Nishimura, T.
    Nishinaka, T.
    Okamoto, E.
    Tokunaga, S.
    Tomo, T.
    Tsukiya, T.
    Yagi, Y.
    Yamaoka, T.
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (01) : 1 - 7
  • [15] Vascular pulsatility in patients with a pulsatile- or continuous-flow ventricular assist device
    Travis, Adam R.
    Giridharan, Guruprasad A.
    Pantalos, George M.
    Dowling, Robert D.
    Prabhu, Sumanth D.
    Slaughter, Mark S.
    Sobieski, Mike
    Undar, Akif
    Farrar, David J.
    Koenig, Steven C.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 133 (02) : 517 - 524
  • [16] Monitoring peripheral perfusion in critically ill patients at the bedside
    van Genderen, Michel E.
    van Bommel, Jasper
    Lima, Alexandre
    [J]. CURRENT OPINION IN CRITICAL CARE, 2012, 18 (03) : 273 - 279
  • [17] Significant impact of left ventricular assist device models on the value of flow-mediated dilation: effects of LVAD on endothelial function
    Watanabe, Aya
    Amiya, Eisuke
    Hatano, Masaru
    Watanabe, Masafumi
    Ozeki, Atsuko
    Nitta, Daisuke
    Maki, Hisataka
    Hosoya, Yumiko
    Tsuji, Masaki
    Bujo, Chie
    Saito, Akihito
    Endo, Miyoko
    Kagami, Yukie
    Nemoto, Mariko
    Nawata, Kan
    Kinoshita, Osamu
    Kimura, Mitsutoshi
    Ono, Minoru
    Komuro, Issei
    [J]. HEART AND VESSELS, 2020, 35 (02) : 207 - 213
  • [18] Further Peripheral Vascular Dysfunction in Heart Failure Patients With a Continuous-Flow Left Ventricular Assist Device The Role of Pulsatility
    Witman, Melissa A. H.
    Garten, Ryan S.
    Gifford, Jayson R.
    Groot, H. Jonathan
    Trinity, Joel D.
    Stehlik, Josef
    Nativi, Jose N.
    Selzman, Craig H.
    Drakos, Stavros G.
    Richardson, Russell S.
    [J]. JACC-HEART FAILURE, 2015, 3 (09) : 703 - 711