Assessment of ocular blood flow in continuous-flow ventricular assist device by laser speckle flowgraphy

被引:1
作者
Shimamura, Junichi [1 ,2 ]
Nishinaka, Tomohiro [1 ]
Mizuno, Toshihide [1 ]
Tsukiya, Tomonori [1 ]
Inatomi, Ayako [1 ]
Kobayashi, Futoshi [1 ]
Katagiri, Nobumasa [1 ]
Takewa, Yoshiaki [1 ]
Nishimura, Takashi [1 ,3 ]
Ono, Minoru [2 ]
Tatsumi, Eisuke [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr Res Inst, Dept Artificial Organs, 6-1 Kishibe Shimmachi, Suita, Osaka 5648565, Japan
[2] Univ Tokyo, Dept Cardiac Surg, Tokyo, Japan
[3] Ehime Univ, Dept Cardiovasc & Thorac Surg, Matsuyama, Ehime, Japan
关键词
Peripheral circulation; Ventricular assist device; Laser speckle flowgraphy; Ocular blood flow; ROTATIONAL SPEED; PULSATILITY;
D O I
10.1007/s10047-021-01265-5
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Although the influence of continuous-flow left ventricular assist device (CF-LVAD) support on peripheral circulation has been widely discussed, its monitoring modalities are limited. The aim of this study was to assess the peripheral circulation using the laser speckle flowgraph (LSFG) which can quantitatively measure the ocular blood flow. We implanted a centrifugal CF-LVAD (EVAHEART(R); Sun Medical Technology Research Corporation, Nagano, Japan) in five adult goats (body weight 44.5 +/- 2.9 kg) under general anesthesia. The waveform of the central retinal artery using the mean blur rate (MBR) for ocular blood velocity and fluctuations as a parameter of pulsatility were obtained before LVAD implantation and after LVAD full-bypass support. The MBR waveform and LSFG fluctuation data were compared with the waveform and pulsatility index of the external carotid artery using an ultrasonic flow meter to evaluate circulatory patterns at different levels. The MBR waveform pattern of the central retinal artery was pulsatile before LVAD implantation and less pulsatile under LVAD full bypass. The fluctuation was 14.7 +/- 1.86 before LVAD implantation and 3.85 +/- 0.61 under LVAD full bypass (p < 0.01), respectively. The fluctuations of LSFG showed a strong correlation with the pulsatility index of the external carotid artery meaning that similar changes in circulatory pattern were observed at two different levels. Measuring the ocular blood flow using LSFG has potential utility for the assessment of the status of the peripheral circulation and its pulsatility during CF-LVAD.
引用
收藏
页码:419 / 424
页数:6
相关论文
共 18 条
  • [1] Feasibility of optical coherence tomography angiography to assess changes in retinal microcirculation in ovine haemorrhagic shock
    Alnawaiseh, Maged
    Ertmer, Christian
    Seidel, Laura
    Arnemann, Philip Helge
    Lahme, Larissa
    Kampmeier, Tim-Gerald
    Rehberg, Sebastian Willy
    Heiduschka, Peter
    Eter, Nicole
    Hessler, Michael
    [J]. CRITICAL CARE, 2018, 22
  • [2] Changing pulsatility by delaying the rotational speed phasing of a rotary left ventricular assist device
    Date, Kazuma
    Nishimura, Takashi
    Arakawa, Mamoru
    Takewa, Yoshiaki
    Kishimoto, Satoru
    Umeki, Akihide
    Ando, Masahiko
    Mizuno, Toshihide
    Tsukiya, Tomonori
    Ono, Minoru
    Tatsumi, Eisuke
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2017, 20 (01) : 18 - 25
  • [3] Shifting the pulsatility by increasing the change in rotational speed for a rotary LVAD using a native heart load control system
    Date, Kazuma
    Nishimura, Takashi
    Takewa, Yoshiaki
    Kishimoto, Satoru
    Arakawa, Mamoru
    Umeki, Akihide
    Ando, Masahiko
    Mizuno, Toshihide
    Tsukiya, Tomonori
    Ono, Minoru
    Tatsumi, Eisuke
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2016, 19 (04) : 315 - 321
  • [4] Attenuation in Peripheral Endothelial Function After Continuous Flow Left Ventricular Assist Device Therapy Is Associated With Cardiovascular Adverse Events
    Hasin, Tal
    Matsuzawa, Yasushi
    Guddeti, Raviteja R.
    Aoki, Tatsuo
    Kwon, Taek-Geun
    Schettle, Sarah
    Lennon, Ryan J.
    Chokka, Ramesh G.
    Lerman, Amir
    Kushwaha, Sudhir S.
    [J]. CIRCULATION JOURNAL, 2015, 79 (04) : 770 - 777
  • [5] Ocular Blood Flow Measured Using Laser Speckle Flowgraphy During Aortic Arch Surgery With Antegrade Selective Cerebral Perfusion
    Hayashi, Hironobu
    Okamoto, Masahiro
    Kawanishi, Hideaki
    Matsuura, Toyoaki
    Tabayashi, Nobuoki
    Taniguchi, Shigeki
    Kawaguchi, Masahiko
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2016, 30 (03) : 613 - 618
  • [6] Cerebral Hypoxia Caused by Flow Confliction During Minimally Invasive Cardiac Surgery With Retrograde Perfusion: A Word of Caution
    Kanda, Hirotsugu
    Kunisawa, Takayuki
    Kitahara, Hiroto
    Iida, Takafumi
    Toyama, Yuki
    Kanao-Kanda, Megumi
    Mori, Chie
    Kamiya, Hiroyuki
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2018, 32 (04) : 1838 - 1840
  • [7] Evaluation of cerebral circulation during retrograde perfusion by laser speckle flowgraphy
    Kimura, Fumiaki
    Kanda, Hirotsugu
    Toyama, Yuki
    Kunisawa, Takayuki
    Nagaoka, Taiji
    Yoshida, Akitoshi
    Kitahara, Hiroto
    Kamiya, Hiroyuki
    [J]. GENERAL THORACIC AND CARDIOVASCULAR SURGERY, 2017, 65 (09) : 527 - 531
  • [8] Eighth annual INTERMACS report: Special focus on framing the impact of adverse events
    Kirklin, James K.
    Pagani, Francis D.
    Kormos, Robert L.
    Stevenson, Lynne W.
    Blume, Elizabeth D.
    Myers, Susan L.
    Miller, Marissa A.
    Baldwin, J. Timothy
    Young, James B.
    Naftel, David C.
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (10) : 1080 - 1086
  • [9] Clinical assessment of peripheral circulation
    Lima, Alexandre
    Bakker, Jan
    [J]. CURRENT OPINION IN CRITICAL CARE, 2015, 21 (03) : 226 - 231
  • [10] Japanese registry for Mechanically Assisted Circulatory Support: First report
    Nakatani, Takeshi
    Sase, Kazuhiro
    Oshiyama, Hiroaki
    Akiyama, Masatoshi
    Horie, Masao
    Nawata, Kan
    Nishinaka, Tomohiro
    Tanoue, Yoshihisa
    Toda, Koichi
    Tozawa, Masao
    Yamazaki, Shunichi
    Yanase, Masanobu
    Ohtsu, Hiroshi
    Ishida, Michiko
    Hiramatsu, Ayaka
    Ishii, Kensuke
    Kitamura, Soichiro
    [J]. JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (10) : 1087 - 1096