From Research Tool to Routine Test: CD38 Monitoring in HIV Patients

被引:18
作者
Coetzee, Lindi M. [1 ,2 ]
Tay, Szun Szun [3 ]
Lawrie, Denise [1 ,2 ]
Janossy, George [1 ,2 ]
Glencross, Deborah K. [1 ,2 ]
机构
[1] Univ Witwatersrand, Wits Med Sch, Dept Mol Med & Haematol, Johannesburg, South Africa
[2] Univ Witwatersrand, Natl Hlth Lab Serv, Johannesburg, South Africa
[3] Univ Sydney, Collaborat Transplantat Res Grp, Sydney, NSW 2006, Australia
关键词
CD38; panleucogating; CD4; CD8; HIV infection; quality control; standardization; ACTIVE ANTIRETROVIRAL THERAPY; T-CELL EXHAUSTION; PD-1; EXPRESSION; FLOW-CYTOMETRY; ANTIGEN-EXPRESSION; CD127; PROGNOSTIC VALUE; CD4; INFECTION; ACTIVATION;
D O I
10.1002/cyto.b.20478
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: CD38 expression on CD8+ T lymphocytes in HIV-infected patients is monitored by flow cytometry (FCM). There is however no consensus re CD38 protocols, analyses or result reporting within/between laboratories. Internal quality control measures (QC) were established for a standardized CD38 protocol and a system proposed for reporting CD38 fluctuation in longitudinal HIV+ patient monitoring. Methods: A single-platform (SP) CD38/CD8 protocol was "piggy-backed" onto the standardized "panleucogating" CD45/CD4+ protocol. A weekly QC was established to monitor instrument stability (Flow-SET (TM)) and absolute cell count accuracy and reproducibility (stabilized blood product, Immuno-Trol (TM)). The Mean Fluorescence Intensity (MFI) of CD38 expression on CD8(+)-lymphocytes was monitored on both stabilized blood and HIV-control samples. Linearized MFI values were determined from biological controls, i.e. healthy donor monocytes and granulocytes, and tested as a method of reporting CD38 expression on selected HIV+ patients on ART. Results: The CD45/CD4/CD8/CD3 method for lymphocyte enumeration compared well with the CD38 protocol (CD45/CD4/CD8/CD38) with excellent similarity (+/- 100%) and precision for absolute CD4 and CD8 counts (CVs < 5%). Fluorosphere MFI- (FlowSet (TM), FlowCount (TM)) and color compensation values were exceptionally stable over time. CD38 MFI values established on monocytes as biological control was 4.0 and <2.0 for HIV-control lymphocytes. Conclusions: Monitoring FCM with fluorosphere MFI values, color compensation, and biological controls, can ensure that CD38 analyses are technologically stable. Flow cytometry is thus the preferred method to monitor fluctuations in CD38 MFI (CD38 molecules/cell) associated with HIV-disease progression and/or response to ART and has potential for application across instruments and centers. (C) 2009 Clinical Cytometry Society
引用
收藏
页码:375 / 384
页数:10
相关论文
共 46 条
[1]   Relationship between CD38 expression on peripheral blood T-cells and monocytes, and response to antiretroviral therapy: A one-year longitudinal study of a cohort of chronically infected ART-naive HIV-1+patients [J].
Almeida, Maria ;
Cordero, Miguel ;
Almeida, Julia ;
Orfao, Alberto .
CYTOMETRY PART B-CLINICAL CYTOMETRY, 2007, 72B (01) :22-33
[2]  
ARROZ MJ, 2005, 5 EUR CLIN CELL AN E
[3]   Differential upregulation of CD38 on different T-cell subsets may influence the ability to reconstitute CD4+ T cells under successful highly active antiretroviral therapy [J].
Benito, DM ;
López, M ;
Lozano, S ;
Ballesteros, C ;
Martinez, P ;
González-Lahoz, J ;
Soriano, V .
JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2005, 38 (04) :373-381
[4]  
Bikoue A, 1996, CYTOMETRY, V26, P137, DOI 10.1002/(SICI)1097-0320(19960615)26:2<137::AID-CYTO7>3.0.CO
[5]  
2-D
[6]   Stabilised cellular immuno-fluorescence assay: CD45 expression as a calibration standard for human leukocytes [J].
Bikoue, A ;
Janossy, G ;
Barnett, D .
JOURNAL OF IMMUNOLOGICAL METHODS, 2002, 266 (1-2) :19-32
[7]   Increased numbers of primed activated CD8+CD38+CD45RO+ T cells predict the decline of CD4+ T cells in HIV-1-infected patients [J].
Bofill, M ;
Mocroft, A ;
Lipman, M ;
Medina, E ;
Borthwick, NJ ;
Sabin, CA ;
Timms, A ;
Winter, M ;
Baptista, L ;
Johnson, MA ;
Lee, CA ;
Phillips, AN ;
Janossy, G .
AIDS, 1996, 10 (08) :827-834
[8]   FLUORESCENCE INTENSITY AS A QUALITY-CONTROL PARAMETER IN CLINICAL FLOW-CYTOMETRY [J].
CALDWELL, CW ;
MAGGI, J ;
HENRY, LB ;
TAYLOR, HM .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1987, 88 (04) :447-456
[9]   STANDARDIZATION OF ABSOLUTE CD4(+) LYMPHOCYTE COUNTS ACROSS LABORATORIES - AN EVALUATION OF THE ORTHO CYTORONABSOLUTE FLOW-CYTOMETRY SYSTEM ON NORMAL DONORS [J].
CONNELLY, MC ;
KNIGHT, M ;
GIORGI, JV ;
KAGAN, J ;
LANDAY, AL ;
PARKER, JW ;
PAGE, E ;
SPINO, C ;
WILKENING, C ;
MERCOLINO, TJ .
CYTOMETRY, 1995, 22 (03) :200-210
[10]   Modified Levey-Jennings charts for calculated laboratory tests [J].
Coskun, A .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2006, 44 (04) :387-390