Development of a fast capillary electrophoresis method for the determination of propranolol-Total analysis time reduction strategies

被引:23
作者
Micke, Gustavo Amadeu [1 ]
Costa, Ana Carolina O. [3 ]
Heller, Melina [1 ]
Barcellos, Michelle [1 ]
Piovezan, Marcel [1 ]
Caon, Thiago [1 ]
Leal de Oliveira, Marcone Augusto [2 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
[2] Univ Fed Juiz de Fora, Dept Chem, BR-36036330 Juiz De Fora, MG, Brazil
[3] Univ Sao Paulo, Inst Chem, BR-05508000 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Propranolol; Total analysis time; Short-end injection; Fast method; Effective mobility curves; Peakmaster; SHORT-END INJECTION; ZONE-ELECTROPHORESIS; VALIDATION; OPTIMIZATION; CREATININE; PLASMA; URINE; DRUGS; ACID; CE;
D O I
10.1016/j.chroma.2009.08.083
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this study was to develop a fast capillary electrophoresis method for the determination of propranolol in pharmaceutical preparations. In the method development the pH and constituents of the background electrolyte were selected using the effective mobility versus pH curves. Benzylamine was used as the internal standard. The background electrolyte was composed of 60 mmol L-1 tris(hydroxymethyl)aminomethane and 30 mmol L-1 2-hydroxyisobutyric acid,at pH 8.1. Separation was conducted in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 mu m I.D.) with a short-end injection configuration and direct UV detection at 214 nm. The run time was only 14 s. Three different strategies were studied in order to develop a fast CE method with low total analysis time for propranolol analysis: low flush time (Lflush) 35 runs/h, without flush (Wflush) 52 runs/h, and Invert (switched polarity) 45 runs/h. Since the three strategies developed are statistically equivalent, Mush was selected due to the higher analytical frequency in comparison with the other methods. A few figures of merit of the proposed method include: good linearity (R-2 > 0.9999); limit of detection of 0.5 mg L-1: inter-day precision better than 1.03% (n = 9) and recovery in the range of 95.1-104.5%. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:7957 / 7961
页数:5
相关论文
共 22 条
[11]  
LANDERS JP, 2008, HDB CAPILLARY MICROC, P447
[12]   On-line sample stacking and short-end injection CE for the determination of fluoxetine and norfluoxetine in plasma: Method development and validation using experimental designs [J].
Lu, Chia-Chia ;
Jong, Yuh-Jyh ;
Ferrance, Jerome ;
Ko, We-Kung ;
Wu, Shou-Mei .
ELECTROPHORESIS, 2007, 28 (18) :3290-3295
[13]  
Montgomery D., 2010, Design and Analysis of Experiments, DOI 10.1080/00224065.2005.11980315
[14]   Development and validation of a capillary zone electrophoresis method for the determination of propranolol and N-desisopropylpropranolol in human urine [J].
Nevado, JJB ;
Flores, JR ;
Peñalvo, GC ;
Bernardo, FJG .
ANALYTICA CHIMICA ACTA, 2006, 559 (01) :9-14
[15]  
Pyell U., 2006, ELECTROKINETIC CHROM
[16]   Rapid quantification of total genomic DNA methylation degree by short-end injection capillary zone electrophoresis [J].
Sotgia, Salvatore ;
Carru, Ciriaco ;
Franconi, Flavia ;
Fiori, Paolo Battista ;
Manca, Salvatorica ;
Pettinato, Silvestro ;
Magliona, Stefania ;
Ginanneschi, Renzo ;
Deiana, Luca ;
Zinellu, Angelo .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1185 (01) :145-150
[17]   Eigenmobilities in background electrolytes for capillary zone electrophoresis:: II.: Eigenpeaks in univalent weak electrolytes [J].
Stedry, M ;
Jaros, M ;
Vceláková, K ;
Gas, B .
ELECTROPHORESIS, 2003, 24 (03) :536-547
[18]   Applications of capillary electrophoresis to the analysis of compounds of clinical, forensic, cosmetological, environmental, nutritional and pharmaceutical importance [J].
Tavares, MFM ;
Jager, AV ;
da Silva, CL ;
Moraes, EP ;
Pereira, EA ;
de Lima, EC ;
Fonseca, FN ;
Tonin, FG ;
Micke, GA ;
Santos, MR ;
de Oliveria, MAL ;
de Moraes, MDL ;
van Kampen, MH ;
Fujiya, NM .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2003, 14 (02) :281-290
[19]  
*US PHARM, 1999, US PHARM CONV
[20]   Rapid screening of pKa values of pharmaceuticals by pressure-assisted capillary electrophoresis combined with short-end injection [J].
Wan, H ;
Holmén, A ;
Någård, M ;
Lindberg, W .
JOURNAL OF CHROMATOGRAPHY A, 2002, 979 (1-2) :369-377