Toward fast, low-noise charge-coupled devices for Lynx

被引:26
|
作者
Bautz, Marshall W. [1 ]
Burke, Barry E. [2 ]
Cooper, Michael [2 ]
Craig, David [2 ]
Foster, Richard F. [1 ]
Grant, Catherine E. [1 ]
LaMarr, Beverly J. [1 ]
Leitz, Christopher [2 ]
Malonis, Andrew [1 ]
Miller, Eric D. [1 ]
Prigozhin, Gregory [1 ]
Schuette, Daniel [2 ]
Suntharalingam, Vyshnavi [2 ]
Thayer, Carolyn [1 ]
机构
[1] MIT, Kavli Inst Astrophys & Space Res, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[2] MIT, Lincoln Lab, 77 Massachusetts Ave, Cambridge, MA 02139 USA
关键词
x-rays; charge-coupled device x-ray sensors; high-definition x-ray imager; x-ray grating spectrograph; Lynx;
D O I
10.1117/1.JATIS.5.2.021015
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
Lynx requires large-format x-ray imaging detectors with performance at least as good as the best current-generation devices but with much higher readout rates. We are investigating an advanced charge-coupled device (CCD) detector architecture under development at MIT Lincoln Laboratory for use in the Lynx high-definition x-ray imager and x-ray grating spectrometer instruments. This architecture features a CMOS-compatible detector integrated with parallel CMOS signal processing chains. Fast, low-noise amplifiers and highly parallel signal processing provide the high frame rates required. CMOS-compatibility of the CCD enables low-power charge transfer and signal processing. We report on the performance of CMOS-compatible test CCDs read at pixel rates up to 5.0 Mpixs(-1) (50 times faster than Chandra ACIS CCDs), with transfer clock swings as low as 1.0-V peak-to-peak (power/gate-area comparable to ACIS CCDs at 100 times the parallel transfer rate). We measure read noise of 4.6 electrons RMS at 2.5 MHz and x-ray spectral resolution better than 150-eV full-width at half maximum at 5.9 keV for single-pixel events. We report charge transfer efficiency measurements and demonstrate that buried channel trough implants as narrow as 0.8 mu m are effective in improving charge transfer performance. We find that the charge transfer efficiency of these devices drops significantly as detector temperature is reduced from similar to- 30 degrees C to -60 degrees C. We point out the potential of previously demonstrated curved-detector fabrication technology for simplifying the design of the Lynx high-definition imager. We discuss the expected detector radiation tolerance at these relatively high transfer rates. Finally, we note that the high pixel "aspect ratio" (depletion depth: pixel size approximate to 9:1) of our test devices is similar to that expected for Lynx detectors and discuss implications of this geometry for x-ray performance and noise requirements. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Toward fast, low-noise, low-power digital CCDs for Lynx and other high-energy astrophysics missions
    Bautz, M.
    Foster, R.
    LaMarr, B.
    Malonis, A.
    Prigozhin, G.
    Miller, E.
    Grant, C. E.
    Burke, B.
    Cooper, M.
    Craig, D.
    Leitz, C.
    Schuette, D.
    Suntharalingam, V.
    SPACE TELESCOPES AND INSTRUMENTATION 2018: ULTRAVIOLET TO GAMMA RAY, 2018, 10699
  • [22] Radiation damage in charge-coupled devices
    Bassler, Niels
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2010, 49 (03) : 373 - 378
  • [23] Echelle spectrometers and charge-coupled devices
    BeckerRoss, H
    Florek, SV
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (9-10) : 1367 - 1375
  • [24] Charge-coupled devices in infrared imaging
    Mooney, Jon
    Optics and Photonics News, 1995, 6 (04): : 29 - 31
  • [25] NEW STRUCTURES FOR CHARGE-COUPLED DEVICES
    SCHUERMEYER, FL
    BELT, RA
    YOUNG, CR
    BLASINGA.JM
    PROCEEDINGS OF THE IEEE, 1972, 60 (11) : 1444 - 1445
  • [26] The latent imager [charge-coupled devices]
    Williamson, Mark
    Engineering and Technology, 2009, 4 (14): : 36 - 39
  • [27] INTERLACING IN CHARGE-COUPLED IMAGING DEVICES
    SEQUIN, CH
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1973, ED20 (06) : 535 - 541
  • [28] Proton effects in charge-coupled devices
    Hopkinson, GR
    Dale, CJ
    Marshall, PW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (02) : 614 - 627
  • [29] Radiation damage in charge-coupled devices
    Niels Bassler
    Radiation and Environmental Biophysics, 2010, 49 : 373 - 378
  • [30] SIMPLE MODEL FOR CHARGE-COUPLED DEVICES
    JAYADEVAIAH, TS
    LAUR, J
    ELECTRONICS LETTERS, 1971, 7 (25) : 751 - +