Development of Low Cost Rapid Fabrication of Sharp Polymer Microneedles for In Vivo Glucose Biosensing Applications

被引:48
作者
Barrett, Colm [1 ]
Dawson, Karen [1 ]
O'Mahony, Conor [1 ]
O'Riordan, Alan [1 ]
机构
[1] Natl Univ Ireland Univ Coll Cork, Tyndall Natl Inst, Cork, Ireland
基金
爱尔兰科学基金会;
关键词
AMPEROMETRIC DETECTION; ARRAY; DRUG; ELECTRODE; DELIVERY; SILICON; NANOELECTRODES; DEVICES;
D O I
10.1149/2.0141510jss
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
New approaches to enable more effective management of diabetes mellitus, such as continuous glucose monitoring are being developed both to prevent unstable episodes of hypo or hyper glycaemia and also to provide an improved user experience. One emerging approach to realize these requirements is to fabricate a minimally invasive transdermal sensor for the direct in vivo detection of glucose in the interstitial fluid. Microneedles - sharp, microscopic structures measuring less than 1 mm in length - have been previously employed to allow painless penetration of the stratum corneum for delivery of drugs and vaccines. In this work we present, ultra sharp gold coated polymer microneedle arrays (sub micron tip radii) which are fabricated using a low cost polymer replication approach. Critical dimensions of the microneedle arrays are characterized using a combination of optical and scanning electron microscopies. Fabricated microneedle devices are characterized by cyclic voltammetry to explore functionality. The voltammetric detection of glucose is performed using ferrocene monocarboxylic acid as an oxidising mediator in the presence of glucose oxidase. The biosensor can be applied to the quantification of glucose in the physiological range (2 - 13.5 mM). The sensors demonstrate high selectivity towards glucose with negligible interference from other oxidizable species including uric acid, ascorbic acid, mannose, fructose, salicylic acid (Aspirin) and acetaminophen (Paracetamol). This demonstrates potential future use of these microneedle devices for in vivo glucose detection. (C) The Author(s) 2015. Published by ECS. This is an open access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives 4.0 License (CC BY-NC-ND, http://creativecommons.org/licenses/by-nc-nd/4.0/), which permits non-commercial reuse, distribution, and reproduction in any medium, provided the original work is not changed in any way and is properly cited. For permission for commercial reuse, please email: oa@electrochem.org. All rights reserved.
引用
收藏
页码:S3053 / S3058
页数:6
相关论文
共 43 条
[1]  
Abla MJ, 2013, THER DELIV, V4, P543, DOI [10.4155/tde.13.24, 10.4155/TDE.13.24]
[2]  
[Anonymous], 2001, ELECTROCHEMICAL METH
[3]   Nanoelectrodes, nanoelectrode arrays and their applications [J].
Arrigan, DWM .
ANALYST, 2004, 129 (12) :1157-1165
[4]   Highly sensitive detection of nitroaromatic explosives at discrete nanowire arrays [J].
Barry, Sean ;
Dawson, Karen ;
Correa, Elon ;
Goodacre, Royston ;
O'Riordan, Alan .
FARADAY DISCUSSIONS, 2013, 164 :283-293
[5]   Voltammetric characterisation of silicon-based microelectrode arrays and their application to mercury-free stripping voltammetry of copper ions [J].
Berduque, Alfonso ;
Lanyon, Yvonne H. ;
Beni, Valerio ;
Herzog, Gregoire ;
Watson, Yvonne E. ;
Rodgers, Kenneth ;
Stam, Frank ;
Alderman, John ;
Arrigan, Damien W. M. .
TALANTA, 2007, 71 (03) :1022-1030
[6]   Microneedle Array Design Determines the Induction of Protective Memory CD8+ T Cell Responses Induced by a Recombinant Live Malaria Vaccine in Mice [J].
Carey, John B. ;
Pearson, Frances E. ;
Vrdoljak, Anto ;
McGrath, Marie G. ;
Crean, Abina M. ;
Walsh, Patrick T. ;
Doody, Timothy ;
O'Mahony, Conor ;
Hill, Adrian V. S. ;
Moore, Anne C. .
PLOS ONE, 2011, 6 (07)
[7]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671
[8]   Mediated biosensors [J].
Chaubey, A ;
Malhotra, BD .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :441-456
[9]   Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis [J].
Chen, Chuanpin ;
Teng, Wei ;
Hahn, Jong Hoon .
ELECTROPHORESIS, 2011, 32 (08) :838-843
[10]   Insertion of microneedles into skin: measurement and prediction of insertion force and needle fracture force [J].
Davis, SP ;
Landis, BJ ;
Adams, ZH ;
Allen, MG ;
Prausnitz, MR .
JOURNAL OF BIOMECHANICS, 2004, 37 (08) :1155-1163