Evaluating a New Contrast Media Injection System in Coronary CT Angiography

被引:0
作者
Martin, Simon S. [1 ,2 ]
Giovagnoli, Dante A. [1 ]
Vingiani, Vincenzo [1 ]
Abadia, Andres F. [1 ]
Fischer, Andreas M. [1 ]
Smith, Hubert E. [1 ]
Wertis, Elyse M. [1 ]
Hook, Kelly [1 ]
Smith, Sandra N. [1 ]
Wasden, Tiffany [1 ]
Kaminski, Jenny [1 ]
Varga-Szemes, Akos [1 ]
Vogl, Thomas J. [2 ]
Schoepf, U. Joseph [1 ]
机构
[1] Med Univ South Carolina, Div Cardiovasc Imaging, Charleston, SC USA
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
computed tomography; coronary CT angiography; contrast media; injector; patient safety; DIAGNOSTIC PERFORMANCE; POWER INJECTOR; IMAGE QUALITY; HELICAL CT; RADIATION; VOLTAGE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate a new contrast media (CM) injection system in patients undergoing coronary computed tomography angiography (CCTA). Methods Seventy-one consecutive patients (33 men and 38 women, mean age 59.0 +/- 14.5 years) who underwent CCTA between February and April 2019 using the CT injection system MEDRAD Stellant FLEX (Bayer) were included retrospectively in this single-center study. Quantitative and qualitative image quality parameters were assessed, and the injection system's usability and operational efficiency were evaluated. Results were compared with a matched control group. Results All examinations were rated as diagnostic. Usability and operational efficiency of the new injector were rated higher than that of the standard injector system, and no significant differences were found for quantitative and qualitative image quality parameters compared with the control group (P >=.05). Discussion Software-based injection facilitates individualized CM application while maintaining high image quality standards in CCTA. Diagnostic accuracy analysis was not performed, but as image quality analysis showed no significant differences, no discrepancies regarding this issue are expected. Conclusion This study demonstrates that the MEDRAD Stellant FLEX CT injection system allows for consistent high-quality CCTA scanning with increased usability and operational efficiency.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 16 条
[11]   Coronary CT angiography using low concentrated contrast media injected with high flow rates: Feasible in clinical practice [J].
Mihl, Casper ;
Kok, Madeleine ;
Wildberger, Joachim E. ;
Altintas, Sibel ;
Labus, David ;
Nijssen, Estelle C. ;
Hendriks, Babs M. F. ;
Kietselaer, Bas L. J. H. ;
Das, Marco .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (11) :2155-2160
[12]   SAFE USE OF AN INTRAVENOUS POWER INJECTOR FOR CT - EXPERIENCE AND PROTOCOL [J].
MILES, SG ;
RASMUSSEN, JF ;
LITWILLER, T ;
OSIK, A .
RADIOLOGY, 1990, 176 (01) :69-70
[13]   Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique-comparison with traditional filtered back projection [J].
Moscariello, Antonio ;
Takx, Richard A. P. ;
Schoepf, U. Joseph ;
Renker, Matthias ;
Zwerner, Peter L. ;
O'Brien, Terrence X. ;
Allmendinger, Thomas ;
Vogt, Sebastian ;
Schmidt, Bernhard ;
Savino, Giancarlo ;
Fink, Christian ;
Bonomo, Lorenzo ;
Henzler, Thomas .
EUROPEAN RADIOLOGY, 2011, 21 (10) :2130-2138
[14]   Diagnostic Performance of Noninvasive Fractional Flow Reserve Derived From Coronary Computed Tomography Angiography in Suspected Coronary Artery Disease The NXT Trial (Analysis of Coronary Blood Flow Using CT Angiography: Next Steps) [J].
Norgaard, Bjarne L. ;
Leipsic, Jonathon ;
Gaur, Sara ;
Seneviratne, Sujith ;
Ko, Brian S. ;
Ito, Hiroshi ;
Jensen, Jesper M. ;
Mauri, Laura ;
De Bruyne, Bernard ;
Bezerra, Hiram ;
Osawa, Kazuhiro ;
Marwan, Mohamed ;
Naber, Christoph ;
Erglis, Andrejs ;
Park, Seung-Jung ;
Christiansen, Evald H. ;
Kaltoft, Anne ;
Lassen, Jens F. ;
Botker, Hans Erik ;
Achenbach, Stephan .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) :1145-1155
[15]   Coronary CT angiography [J].
Schoepf, U. Joseph ;
Zwerner, Peter L. ;
Savino, Giancarlo ;
Herzog, Christopher ;
Kerl, J. Matthias ;
Costello, Philip .
RADIOLOGY, 2007, 244 (01) :48-63
[16]   Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography [J].
Trattner, Sigal ;
Halliburton, Sandra ;
Thompson, Carla M. ;
Xu, Yanping ;
Chelliah, Anjali ;
Jambawalikar, Sachin R. ;
Peng, Boyu ;
Peters, M. Robert ;
Jacobs, Jill E. ;
Ghesani, Munir ;
Jang, James J. ;
Al-Khalidi, Hussein ;
Einstein, Andrew J. .
JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) :64-74