Evaluating a New Contrast Media Injection System in Coronary CT Angiography

被引:0
作者
Martin, Simon S. [1 ,2 ]
Giovagnoli, Dante A. [1 ]
Vingiani, Vincenzo [1 ]
Abadia, Andres F. [1 ]
Fischer, Andreas M. [1 ]
Smith, Hubert E. [1 ]
Wertis, Elyse M. [1 ]
Hook, Kelly [1 ]
Smith, Sandra N. [1 ]
Wasden, Tiffany [1 ]
Kaminski, Jenny [1 ]
Varga-Szemes, Akos [1 ]
Vogl, Thomas J. [2 ]
Schoepf, U. Joseph [1 ]
机构
[1] Med Univ South Carolina, Div Cardiovasc Imaging, Charleston, SC USA
[2] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
关键词
computed tomography; coronary CT angiography; contrast media; injector; patient safety; DIAGNOSTIC PERFORMANCE; POWER INJECTOR; IMAGE QUALITY; HELICAL CT; RADIATION; VOLTAGE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate a new contrast media (CM) injection system in patients undergoing coronary computed tomography angiography (CCTA). Methods Seventy-one consecutive patients (33 men and 38 women, mean age 59.0 +/- 14.5 years) who underwent CCTA between February and April 2019 using the CT injection system MEDRAD Stellant FLEX (Bayer) were included retrospectively in this single-center study. Quantitative and qualitative image quality parameters were assessed, and the injection system's usability and operational efficiency were evaluated. Results were compared with a matched control group. Results All examinations were rated as diagnostic. Usability and operational efficiency of the new injector were rated higher than that of the standard injector system, and no significant differences were found for quantitative and qualitative image quality parameters compared with the control group (P >=.05). Discussion Software-based injection facilitates individualized CM application while maintaining high image quality standards in CCTA. Diagnostic accuracy analysis was not performed, but as image quality analysis showed no significant differences, no discrepancies regarding this issue are expected. Conclusion This study demonstrates that the MEDRAD Stellant FLEX CT injection system allows for consistent high-quality CCTA scanning with increased usability and operational efficiency.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 16 条
[1]   High-pitch low-voltage CT coronary artery calcium scoring with tin filtration: accuracy and radiation dose reduction [J].
Apfaltrer, Georg ;
Albrecht, Moritz H. ;
Schoepf, U. Joseph ;
Duguay, Taylor M. ;
De Cecco, Carlo N. ;
Nance, John W. ;
De Santis, Domenico ;
Apfaltrer, Paul ;
Eid, Marwen H. ;
Eason, Chelsea D. ;
Thompson, Zachary M. ;
Bauer, Maximilian J. ;
Varga-Szemes, Akos ;
Jacobs, Brian E. ;
Sorantin, Erich ;
Tesche, Christian .
EUROPEAN RADIOLOGY, 2018, 28 (07) :3097-3104
[2]   Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches [J].
Bae, Kyongtae T. .
RADIOLOGY, 2010, 256 (01) :32-61
[3]   Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy [J].
Brodoefel, Harald ;
Burgstahler, Christof ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Schroeder, Stephen ;
Claussen, Claus D. ;
Heuschmid, Martin ;
Kopp, Andreas F. .
RADIOLOGY, 2008, 247 (02) :346-355
[4]   Intravenous contrast material administration at 16-detector row helical CT coronary angiography: Test bolus versus bolus-tracking technique [J].
Cademartiri, F ;
Nieman, K ;
van der Lugt, A ;
Raaijmakers, RH ;
Mollet, N ;
Pattynama, PMT ;
de Feyter, PJ ;
Krestin, GP .
RADIOLOGY, 2004, 233 (03) :817-823
[5]   Radiation and contrast agent doses reductions by using 80-kV tube voltage in coronary computed tomographic angiography: A comparative study [J].
Cao, Jian-xin ;
Wang, Yi-min ;
Lu, Jin-guo ;
Zhang, Yu ;
Wang, Peng ;
Yang, Cheng .
EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (02) :309-314
[6]   Fractional Flow Reserve Computed from Noninvasive CT Angiography Data: Diagnostic Performance of an On-Site Clinician-operated Computational Fluid Dynamics Algorithm [J].
Coenen, Adriaan ;
Lubbers, Marisa M. ;
Kurata, Akira ;
Kono, Atsushi ;
Dedic, Admir ;
Chelu, Raluca G. ;
Dijkshoorn, Marcel L. ;
Gijsen, Frank J. ;
Ouhlous, Mohamed ;
van Geuns, Robert-Jan M. ;
Nieman, Koen .
RADIOLOGY, 2015, 274 (03) :674-683
[7]   Reduction of contrast material dose and artifacts by a saline flush using a double power injector in helical CT of the thorax [J].
Haage, P ;
Schmitz-Rode, T ;
Hübner, D ;
Piroth, W ;
Günther, RW .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (04) :1049-1053
[8]   Individually tailored contrast enhancement in CT pulmonary angiography [J].
Hendriks, Babs M. F. ;
Kok, Madeleine ;
Mihl, Casper ;
Bekkers, Sebastiaan C. A. M. ;
Wildberger, Joachim E. ;
Das, Marco .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1061)
[9]   Does two-segment image reconstruction at 64-section CT coronary angiography improve image quality and diagnostic accuracy? [J].
Herzog, Christopher ;
Nguyen, Shaun A. ;
Savino, Giancarlo ;
Zwerner, Peter L. ;
Doll, Josh ;
Nielsen, Christopher D. ;
Flohr, Thomas G. ;
Vogl, Thomas J. ;
Costello, Philip ;
Schoepf, U. Joseph .
RADIOLOGY, 2007, 244 (01) :121-129
[10]   Evaluation of individually body weight adapted contrast media injection in coronary CT-angiography [J].
Mihl, Casper ;
Kok, Madeleine ;
Altintas, Sibel ;
Kietselaer, Bas L. J. H. ;
Turek, Jakub ;
Wildberger, Joachim E. ;
Das, Marco .