SPECT attenuation correction: An essential tool to realize nuclear cardiology's manifest destiny

被引:70
作者
Garcia, Ernest V. [1 ]
机构
[1] Emory Univ Hosp, Atlanta, GA 30322 USA
关键词
SPECT; attenuation correction; absolute quantification; myocardial perfusion imaging;
D O I
10.1016/j.nuclcard.2006.12.144
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Single photon emission computed tomography (SPECT) myocardial perfusion imaging has attained widespread clinical acceptance as a standard of care for cardiac patients. Yet, physical phenomena degrade the accuracy of how our cardiac images are visually interpreted or quantitatively analyzed. This degradation results in cardiac images in which brightness or counts are not necessarily linear with tracer uptake or myocardial perfusion. Attenuation correction (AC) is a methodology that has evolved over the last 30 years to compensate for this degradation. Numerous AC clinical trials over the last 10 years have shown increased diagnostic accuracy over non-AC SPECT for detecting and localizing coronary artery disease, particularly for significantly increasing specificity and normalcy rate. This overwhelming evidence has prompted our professional societies to issue a joint position statement in 2004 recommending the use of AC to maximize SPECT diagnostic accuracy and clinical usefulness. Phantom and animal studies have convincingly shown how SPECT AC recovers the true regional myocardial activity concentration, while non-AC SPECT does not. Thus, AC is also an essential tool for extracting quantitative parameters from all types of cardiac radionuclide distributions, and plays an important role in establishing cardiac SPECT for flow, metabolic, innervation, and molecular imaging, our manifest destiny.
引用
收藏
页码:16 / 24
页数:9
相关论文
共 43 条
  • [11] Simultaneous transmission emission myocardial perfusion tomography diagnostic accuracy of attenuatian-corrected Tc-99m-sestamibi single-photon emission computed tomography
    Ficaro, EP
    Fessler, JA
    Shreve, PD
    Kritzman, JN
    Rose, PA
    Corbett, JR
    [J]. CIRCULATION, 1996, 93 (03) : 463 - 473
  • [12] Should SPET attenuation correction be more widely employed in routine clinical practice? For
    Ficaro, EP
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (03) : 409 - 412
  • [13] Attenuation-corrected thallium-201 single-photon emission tomography using a gadolinium-153 moving line source: clinical value and the impact of attenuation correction on the extent and severity of perfusion abnormalities
    Gallowitsch, HJ
    Sykora, J
    Mikosch, P
    Kresnik, E
    Unterweger, O
    Molnar, M
    Grimm, G
    Lind, P
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (03) : 220 - 228
  • [14] EFFECTS OF MYOCARDIAL WALL THICKNESS ON SPECT QUANTIFICATION
    GALT, JR
    GARCIA, EV
    ROBBINS, WL
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) : 144 - 150
  • [15] QUANTITATIVE MYOCARDIAL PERFUSION SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHIC IMAGING - QUO-VADIS - (WHERE DO WE GO FROM HERE)
    GARCIA, EV
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (01) : 83 - 93
  • [16] Low event rate for stress-only perfusion imaging in patients evaluated for chest pain
    Gibson, PB
    Demus, D
    Noto, R
    Hudson, W
    Johnson, LL
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (06) : 999 - 1004
  • [17] Quantitative Tc-99m attenuation-corrected sestamibi SPECT: Development and multicenter trial validation of myocardial perfusion stress gender-independent normal database in an obese population
    Grossman, GB
    Garcia, EV
    Bateman, TM
    Heller, GV
    Johnson, LL
    Folks, RD
    Cullom, SJ
    Galt, JR
    Case, JA
    Santana, CA
    Halkar, RK
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) : 263 - 272
  • [18] Clinical value of attenuation correction in stress-only Tc-99m sestamibi SPECT imaging
    Heller, GV
    Bateman, TM
    Johnson, LL
    Cullom, SJ
    Case, JA
    Galt, JR
    Garcia, EV
    Haddock, K
    Moutray, KL
    Poston, C
    Botvinick, EH
    Fish, MB
    Follansbee, WP
    Hayes, S
    Iskandrian, AE
    Mahmarian, JJ
    Vandecker, W
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (03) : 273 - 281
  • [19] American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy
    Heller, GV
    Links, J
    Bateman, TM
    Ziffer, JA
    Ficaro, E
    Cohen, MC
    Hendel, RC
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2004, 11 (02) : 229 - 230
  • [20] Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging
    Hendel, RC
    Berman, DS
    Cullom, SJ
    Follansbee, W
    Heller, GV
    Kiat, H
    Groch, MW
    Mahmarian, JJ
    [J]. CIRCULATION, 1999, 99 (21) : 2742 - 2749