The intra- and inter-observer reliability of interface pressure measurements of the Milwaukee brace in adolescents with hyperkyphosis

被引:2
作者
Babaee, Taher [1 ]
Kamyab, Mojtaba [1 ]
Ahmadi, Amir [2 ]
Sanjari, Mohammad Ali [3 ]
Ganjavian, Mohammad Saleh [4 ]
机构
[1] Iran Univ Med Sci, Sch Rehabil Sci, Dept Orthot & Prosthet, Madadkaran Ave,Shahnazari St,Madar Sq, Tehran, Iran
[2] Iran Univ Med Sci, Sch Rehabil Sci, Dept Physiotherapy, Tehran, Iran
[3] Iran Univ Med Sci, Rehabil Res Ctr, Sch Rehabil, Dept Rehabil Basic Sci,Biomech Lab, Tehran, Iran
[4] Iran Univ Med Sci, Shafa Yahyaiian Hosp, Dept Orthopaed Surg, Tehran, Iran
关键词
Pressure measurement; brace; Scheuermann's kyphosis; sphygmomanometer; reliability; FORCE MEASUREMENTS; SPHYGMOMANOMETER; VALIDATION; KYPHOSIS; SYSTEM;
D O I
10.3233/BMR-171041
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: There is a lack of evidence in reliability of the modified sphygmomanometer to measure the brace-interface pad pressure in adolescents with Scheuermann's kyphosis (SK). OBJECTIVES: To evaluate the intra- and inter-observer reliability of modified sphygmomanometer for measuring interface pad pressure in the Milwaukee brace. METHODS: Two observers measured the pressure of the shoulder and kyphosis pads in Milwaukee brace on 33 adolescents with SK with an average age of 14.67 +/- 1.72 years and Cobb angle 64.48 degrees +/- 7.53 degrees . All measurements were obtained in one day. The measurements were done in the inhalation and exhalation of tidal breathing during standing and sitting positions. The intraclass correlation coefficient (ICC), 95% confidence interval (CI), and linear mixed model ANOVA effects were calculated. RESULTS: The intra-observer reliability varied from a good ICC of 0.81 (0.66-0.90) to an excellent of 0.97 (0.95-0.98). The inter-observer reliability also varied from a good ICC of 0.82 (0.67-0.91) to an excellent of 0.96 (0.93-0.98). The linear mixed model ANOVA analysis showed that the rater, position, and breathing had a significant effect on the pad pressure measurements. CONCLUSIONS: The modified sphygmomanometer is a reliable tool to measure the pad pressure of the Milwaukee brace for adolescents with SK.
引用
收藏
页码:647 / 654
页数:8
相关论文
共 25 条
  • [1] Ascani E, 1977, Ital J Orthop Traumatol, V3, P111
  • [2] Babaee T, 2017, ASIAN SPINE J, V11, P627, DOI 10.4184/asj.2017.11.4.627
  • [3] Review of current technologies and methods supplementing brace treatment in adolescent idiopathic scoliosis
    Chan, Andrew
    Lou, Edmond
    Hill, Doug
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2013, 7 (04) : 309 - 316
  • [4] Design and validation of transducers to measure interface force distribution in a spinal orthosis
    Chan, Andrew
    Lou, Edmond
    Hill, Doug
    Faulkner, Gary
    [J]. MEDICAL ENGINEERING & PHYSICS, 2012, 34 (09) : 1310 - 1316
  • [5] Fleiss J., 1986, Reliability of measurement: the design and analysis of clinical experiments
  • [6] MEASUREMENT OF GRIP STRENGTH - VALIDITY AND RELIABILITY OF THE SPHYGMOMANOMETER AND JAMAR GRIP DYNAMOMETER
    HAMILTON, GF
    MCDONALD, C
    CHENIER, TC
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1992, 16 (05) : 215 - 219
  • [7] Scheuermann's Thoracic Kyphosis in the Adolescent Patient
    Hart, Erin S.
    Merlin, Gabriel
    Harisiades, Jamie
    Grottkau, Brian E.
    [J]. ORTHOPAEDIC NURSING, 2010, 29 (06) : 365 - 371
  • [8] Hsu JD, 2008, AAOS ATLAS ORTHOSES, P125
  • [9] Innes E., 1999, Australian Occupational Therapy Journal, V46, P120, DOI DOI 10.1046/J.1440-1630.1999.00182.X
  • [10] John RF, 2008, AAOS ATLAS ORTHOSES, P89