Non-rigid image registration using mutual information

被引:0
|
作者
Maes, Frederik [1 ]
D'Agostino, Emiliano [1 ]
Loeckx, Dirk [1 ]
Wouters, Jeroen [1 ]
Vandermeulen, Dirk [1 ]
Suetens, Paul [1 ]
机构
[1] Katholieke Univ Leuven, ESAT, PSI, Med Image Comp, Herestr 49, B-3000 Louvain, Belgium
关键词
non-rigid image registration; mutual information;
D O I
10.1007/978-3-7908-1709-6_8
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Robust intensity-based non-rigid image registration and its application for image-based morphometry and the characterization of shape variation and variability is an important research topic in medical image analysis. Recent research in the field has focused on extending the mutual information based registration criterion to non-rigid matching, which is complicated by the statistical nature of the criterion and by the local impact of the non-rigid deformation parameters. In this paper we describe the state of the art in the field and ongoing work within our own research group.
引用
收藏
页码:91 / +
页数:5
相关论文
共 50 条
  • [31] Non-Rigid Image Registration by Neural Computation
    Rujirutana Srikanchana
    Jianhua Xuan
    Matthew T. Freedman
    Charles C. Nguyen
    Yue Wang
    Journal of VLSI signal processing systems for signal, image and video technology, 2004, 37 : 237 - 246
  • [32] An improved non-rigid image registration approach
    He K.
    Wei Y.
    Wang Y.
    Huang W.-R.
    Gongcheng Kexue Xuebao/Chinese Journal of Engineering, 2019, 41 (07): : 955 - 960
  • [33] Mutual information based registration for 3D non-rigid medical images
    Chen, Yu
    Zhuang, Tiange
    Shanghai Jiaotong Daxue Xuebao/Journal of Shanghai Jiaotong University, 1999, 33 (09): : 1125 - 1127
  • [34] Non-rigid registration using morphons
    Wrangsjö, A
    Pettersson, J
    Knutsson, H
    IMAGE ANALYSIS, PROCEEDINGS, 2005, 3540 : 501 - 510
  • [35] Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information
    Gong, Lun
    Wang, Haifeng
    Peng, Chengtao
    Dai, Yakang
    Ding, Min
    Sun, Yinghao
    Yang, Xiaodong
    Zheng, Jian
    BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [36] Non-rigid MR-TRUS image registration for image-guided prostate biopsy using correlation ratio-based mutual information
    Lun Gong
    Haifeng Wang
    Chengtao Peng
    Yakang Dai
    Min Ding
    Yinghao Sun
    Xiaodong Yang
    Jian Zheng
    BioMedical Engineering OnLine, 16
  • [37] Non-rigid medical image registration using image field in Demons algorithm
    Lan, Sheng
    Guo, Zhenhua
    You, Jane
    PATTERN RECOGNITION LETTERS, 2019, 125 : 98 - 104
  • [38] Non-Rigid Ultrasound Image Registration Based on Intensity and Local Phase Information
    Woo, Jonghye
    Hong, Byung-Woo
    Hu, Chang-Hong
    Shung, K. Kirk
    Kuo, C. -C. Jay
    Slomka, Piotr J.
    JOURNAL OF SIGNAL PROCESSING SYSTEMS FOR SIGNAL IMAGE AND VIDEO TECHNOLOGY, 2009, 54 (1-3): : 33 - 43
  • [39] Non-Rigid Ultrasound Image Registration Based on Intensity and Local Phase Information
    Jonghye Woo
    Byung-Woo Hong
    Chang-Hong Hu
    K. Kirk Shung
    C.-C. Jay Kuo
    Piotr J. Slomka
    Journal of Signal Processing Systems, 2009, 54 : 33 - 43
  • [40] Non-rigid image registration using a statistical spline deformation model
    Loeckx, D
    Maes, F
    Vandermeulen, D
    Suetens, P
    INFORMATION PROCESSING IN MEDICAL IMAGING, PROCEEDINGS, 2003, 2732 : 463 - 474