Full Three-Dimensional Strain Measurements on Wood Exposed to Three-Point Bending: Analysis by Use of Digital Volume Correlation Applied to Synchrotron Radiation Micro-Computed Tomography Image Data

被引:92
作者
Forsberg, F. [1 ]
Sjodahl, M. [1 ]
Mooser, R. [2 ]
Hack, E. [2 ]
Wyss, P. [2 ]
机构
[1] Lulea Univ Technol, Div Expt Mech, SE-97187 Lulea, Sweden
[2] Swiss Fed Labs Mat Testing & Res EMPA, Elect Metrol Reliabil Lab, CH-8600 Dubendorf, Switzerland
关键词
3D strain; digital image correlation; digital volume correlation; displacement field; three-point bend; wood structure; X-ray tomography; ELECTRONIC SPECKLE PHOTOGRAPHY; FRACTURE PROCESS ZONE; ACCURACY; CRACK; DEFORMATION; TIP; MICROTOMOGRAPHY; INTERFEROMETRY; MINIMIZATION; CONCRETE;
D O I
10.1111/j.1475-1305.2009.00687.x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A microscale three-point bend experiment on wood has been carried out. The full 3D strain field of the microscale wood structure has been determined by use of digital volume correlation, based on reconstructed 3D image data acquired with synchrotron radiation micro-computed tomography. The wood specimen, which measures 1.57 x 3.42 x 0.75 mm3, was scanned in different load states along the three-point bend load cycle, from unloaded state to failure. The correlation algorithm is based on a Chebyshev polynomial description of the displacements, which allows a continuous representation of the 3D deformation fields. The methodology of the correlation algorithm is described thoroughly and its performance is tested for a 3D structure that is exposed to a virtual pre-defined deformation. The performance is tested both for noise free volume data as well as for structures with additive noise content. The performance test shows that the correlation algorithm resolves the applied deformation satisfyingly well. In the real experiment, on wood microstructure, the displacement fields show a structural behaviour that is consistent with what is expected for a specimen exposed to three-point bend. However, there are also anomalous effects present in the displacement fields that can be coupled to characteristic features in the cellular structure of the wood. Furthermore, 3D strain calculations based on the obtained displacement data shows a concentration of tensile strain in the region where the specimen eventually collapses. The experimental results show that the use of X-ray-based tomography with high spatial resolution in combination with digital volume correlation can successfully be used to perform 3D strain measurements on wood, at the microscale.
引用
收藏
页码:47 / 60
页数:14
相关论文
共 35 条
[1]   Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[2]   DIGITAL IMAGE CORRELATION USING NEWTON-RAPHSON METHOD OF PARTIAL-DIFFERENTIAL CORRECTION [J].
BRUCK, HA ;
MCNEILL, SR ;
SUTTON, MA ;
PETERS, WH .
EXPERIMENTAL MECHANICS, 1989, 29 (03) :261-267
[3]   ON THE SENSITIVITY OF COHERENT GRADIENT SENSING .2. AN EXPERIMENTAL INVESTIGATION OF ACCURACY IN FRACTURE-MECHANICS APPLICATIONS [J].
BRUCK, HA ;
ROSAKIS, AJ .
OPTICS AND LASERS IN ENGINEERING, 1993, 18 (01) :25-51
[4]   Speckle interferometry with nanoparticles [J].
Chiang, FP ;
Wang, Q .
INTERNATIONAL CONFERENCE ON APPLIED OPTICAL METROLOGY, 1998, 3407 :310-317
[5]  
CHOI D, 1991, WOOD SCI TECHNOL, V25, P251, DOI 10.1007/BF00225465
[6]   An interior trust region approach for nonlinear minimization subject to bounds [J].
Coleman, TF ;
Li, YY .
SIAM JOURNAL ON OPTIMIZATION, 1996, 6 (02) :418-445
[7]  
Danvind J., 2001, INT IUFRO WOOD DRYIN, P276
[8]  
DU J, 1992, ACI MATER J, V89, P252
[9]  
Fung YC, 1994, 1 COURSE CONTINUUM M
[10]  
GUO ZK, 1993, ENG FRACT MECH, V46, P1041